Analytical and Monte Carlo comparisons on the optical transport mechanisms of powder phosphors
Source abstract
Abstract
Abstract In indirect medical imaging systems, the optical transfer properties of powder phosphor materials are affected by the intrinsic mechanisms of light extinction. Light extinction (absorption and scattering) can be described either through theoretical models or with Monte Carlo simulation techniques. The purpose of the present paper is to compare both methodologies and assess the association of their optical parameters by examining either the structural (e.g., particle size) or the optical (e.g., light wavelength) intrinsic properties of the phosphor. Comparisons were carried out for the widely used host Gd2O2S for granular phosphors. The parameters considered in Monte Carlo simulation were: (i) a phosphor layer composed of grains with diameter 4–12 μm, (ii) the light wavelength (420 nm, 545 nm and 610 nm), (iii) the refractive index of the phosphor (real part: 2.3, imaginary part: 10−6 and 10−5), (iv) the packing density 50%. The results were compared with the Swank analytical model, based in Boltzman diffusion equation, by considering three cases for optical coefficients determination with the help of which the Luminescence Efficiency (LE) and the Modulation Transfer Function (MTF) of the phosphor could be predicted. It was found that Swank's model seems more appropriate for estimating the MTF values, presenting a deviation less than 5% in all the frequency range. for: wavelength 420 nm, considering (i) grain size 4 μm and thicknesses above 250 μm, (ii) grain size 12 μm and thicknesses above 300 μm, (b) wavelength 545 nm, grain size 8 μm and thicknesses above 160 μm, and (c) wavelength 610 nm, considering (i) grain size 4 μm and thicknesses above 200 μm, (ii) grain size 8 μm and thicknesses above 120 μm and (iii) grain size 12 μm and thicknesses above 80 μm.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Luminescence Properties of Advanced Materials · Radiation Detection and Scintillator Technologies · Terahertz technology and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Characterization of scintillator-based detectors for few-ten-keV high-spatial resolution x-ray imaging10.1118/1.4948687 ↗
2. On the response of europium doped phosphor-coated CMOS digital imaging detector10.1016/j.nima.2013.06.107 ↗
3. Light emission efficiency and imaging performance of Lu2O3:Eu nanophosphor under X-ray radiography conditions: comparison with Gd2O2S:Eu10.1016/j.jlumin.2014.02.017 ↗
4. Experimental and theoretical evaluation of a high resolution CMOS based detector under X-ray imaging conditions10.1109/TNS.2010.2094206 ↗
5. Measurement of the luminescence properties of Gd2O2S:Pr,Ce,F powder scintillators under X-ray radiation10.1016/j.radmeas.2014.09.008 ↗
6. Image simulation and a model of noise power spectra across a range of mammographic beam qualities10.1118/1.4900819 ↗
7. Lubberts effect in columnar phosphors10.1118/1.1796151 ↗
8. Fast, angle-depended, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems10.1118/1.3397462 ↗
9. An energy-and depth-dependent model for x-ray imaging10.1118/1.1806293 ↗
10. Optical photon transport in powdered-phosphor scintillators. Part 1. Multiple-scattering and validity of the Boltzmann transport equation
11. Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens10.1118/1.596583 ↗
12. Optimal phosphor thickness for portal imaging10.1118/1.598002 ↗
13. Monte Carlo Simulations of the imaging performance of Metal/Plate phosphor screens used in radiotherapy10.1118/1.598727 ↗
14. Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis
15. Semiempirical simulation of x-ray detectors for imaging applications10.1118/1.4767768 ↗
16. Applied linear-systems theory
17. Calculation of modulation transfer functions of X-ray fluorescent screens10.1364/AO.12.001865 ↗
18. Modeling quantum and structure noise of phosphors used in medical x-ray imaging detectors10.1016/S0168-9002(02)01088-4 ↗
19. An evaluation of the Y2O33+ scintillator for application in medical X-ray detectors and image receptors10.1118/1.597769 ↗
20. Modeling the performance characteristics of computed radiography (CR) systems10.1109/TMI.2009.2036995 ↗
21. Light dosimetry in optical phantoms and in tissues: I.Multiple flux and transport theory10.1088/0031-9155/33/4/004 ↗
22. Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging10.1088/1361-6560/aa8b31 ↗
23. Optical diffusion performance of nanophosphor-based materials for use in medical imaging10.1117/1.JBO.17.12.126013 ↗
24. On the response of GdAlO3:Ce scintillators10.1016/j.jlumin.2013.06.041 ↗
25. Evaluation of Gd2O2S:Pr granular phosphor properties for X-ray mammography imaging10.1016/j.jlumin.2015.01.044 ↗
26. Van de Hulst · 1957
27. Bohren · 1983
28. Modeling granular phosphor screens by Monte Carlo methods10.1118/1.2372217 ↗
29. Optical photon transport in powdered-phosphor scintillators. Part II. Calculation of single-scattering transport parameters
30. Kalyvas · 2014
31. Examining phosphor material properties for imaging purposes: the role of the complex refractive index in the optical diffusion performance10.1088/2057-1976/3/1/015006 ↗
32. Nanostructured materials10.1088/0034-4885/64/3/201 ↗
33. Strain effects on the optical parameters of quantum dots nanocrystals employed in biomedical applications10.1016/j.jlumin.2013.09.050 ↗
34. Optical absorption characteristics in the assessment of powder phosphor-based x-ray detectors: from nano- to micro-scale10.1088/0031-9155/60/22/8885 ↗
35. Optical properties of normal and diseased human breast tissues in the visible and near infrared10.1088/0031-9155/35/9/010 ↗
36. Evaluating x-ray detectors for radiographic applications: a comparison of ZnSCdS:Ag with Gd2O2S:Tb and Y2O2S:Tb screens10.1088/0031-9155/42/7/009 ↗
37. Y2O2S:Eu phosphor screen evaluation10.1118/1.597065 ↗
38. The Monte Carlo evaluation of noise and resolution properties of granular phosphor screens10.1088/0031-9155/54/4/003 ↗
39. Monte Carlo performance on the x-ray converter thickness in digital mammography using software breast models10.1118/1.4757919 ↗
40. Prahl · 2009
41. Liaparinos · 2013
42. Evaluation of Gd2O2S:Tb as a phosphor for the input screen of X-ray image intensifier10.1109/TNS.1972.4326777 ↗