journal article·2008-08

Features of scintillation characteristics of CsI:Na and NaI:Tl crystals as the basis for soft gamma radiation detectors

I.V. Kilimchuk, V.P. Gavrilyuk, B.V. Grinyov, V.A. Tarasov, Yu.T. Viday

Optical Materials· Volume 30· Issue 12
Publisher page

Abstract

Abstract Light collection processes for X-ray and soft gamma radiation detectors were simulated for various detector constructions, reflector types and roughness of detector surfaces. The experimental study of light output and pulse-height resolution of the CsI:Na and NaI:Tl detectors was carried out to check the simulation results and to find out optimal conditions that could maximize scintillation parameters.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Radiation Detection and Scintillator Technologies · Medical Imaging Techniques and Applications · Advanced Semiconductor Detectors and Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (3)

Show source-provided references
1. L.S. Gorn, B.I. Hazanov, Modern Devices for Ionizing Radiation Measurements, Energoatomizdat, Moscow, 1989, p. 232.
2. Averkiev · Instrum. Exp. Tech. · 1990 · 4 · 799
3. Gavrilyuk · Funct. Mater. · 1997 · 4 · 572