Reproducibility analysis of diamond pixel detectors for large ionizing radiation fields
Source abstract
Abstract
This work reports on reproducibility tests performed on 20 high-quality single-crystal chemical vapour deposition (scCVD) diamond samples. By the analysis of the average mobility-lifetime product of the photogenerated carriers, 12 samples were selected and arranged as pixels in a 2.5 × 2.5 cm2 mosaic detector. Measurements carried out under a large (4 cm diameter) X-ray beam show a very high pixel response uniformity (< 1% standard deviation relative to the mean photocurrent value) for a wide range of applied bias voltages (20 ÷ 80 V). Results suggest a very high level of reproducibility, mostly due to the excellent quality of the bulk material, meeting the requirements for monitoring large ionizing radiation fields with no need for individual pixel calibration. Moreover, mobility-lifetime product demonstrated to be the most effective figure of merit for the selection of CVD diamond samples with reproducible detection performance.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced X-ray and CT Imaging · Diamond and Carbon-based Materials Research · Electronic and Structural Properties of Oxides
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Diamond detectors for UV and X-ray source imaging10.1109/LED.2011.2176907 ↗
2. X-ray detection by using CVD single crystal diamond detector10.1109/TNS.2008.2010705 ↗
3. Ultra-thin optical grade scCVD diamond as X-ray beam position monitor10.1107/S1600577514016191 ↗
4. Polycrystalline CVD diamond pixel array detector for nuclear particles monitoring10.1088/1748-0221/8/02/C02043 ↗
5. Super-thin single crystal diamond membrane radiation detectors10.1063/1.4821035 ↗
6. First neutron spectroscopy measurements with pixelated diamond detector at JET10.1063/1.4961557 ↗
7. A diamond based neutron spectrometer for diagnostics of deuterium-tritium fusion plasmas10.1063/1.4885356 ↗
8. Resistant and sensitive single-crystal diamond dosimeters for ionizing radiation10.1016/j.nima.2012.10.095 ↗
9. Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector10.1118/1.4895827 ↗
10. Large single crystal diamond substrates for ionizing radiation detection10.1002/pssa.201600262 ↗
11. A new CVD diamond mosaic-detector for (n, α) cross-section measurements at the n_TOF experiment at CERN10.1016/j.nima.2013.07.040 ↗
12. Mosaic diamond detectors for fast neutrons and large ionizing radiation fields10.1002/pssa.201532191 ↗
13. Reproducibility of CVD diamond detectors for radiotherapy dosimetry10.1016/j.nima.2012.06.034 ↗
14. Zum Mechanismus des lichtelektrischen Primärstromes in isolierenden Kristallen10.1007/BF01338917 ↗
15. Characterisation of single crystal CVD diamond particle detectors for hadron physics experiments10.1002/pssa.200561929 ↗
16. High-voltage single–crystal diamond diodes10.1109/TED.2004.826867 ↗
17. Radiation-assisted Frenkel-Poole transport in single-crystal diamond10.1063/1.4818904 ↗