journal article·2021-09

The effect of the grain size distribution (GSD) on the light emission performance of phosphor-based X-ray detectors

P. Liaparinos, C. Michail, I. Valais, A. Karabotsos, A. Bakas, I. Kandarakis

Optical Materials· Volume 119
Publisher page

Abstract

Abstract The light emission performance of indirect, phosphor-based, X-ray detectors has significantly affected image quality and diagnostic validity of the medical imaging examinations. This issue has been investigated by examining and further understanding the optical anisotropy in optical diffusion mechanisms. One crucial parameter of phosphor's structural properties that remarkably changes light distribution is the size of the phosphor particles. Up to now, the vast majority of studies have been carried out considering phosphor materials consisted of grains of equal size. In the present article an attempt is made to investigate the influence of grain size distribution (GSD) on light emitting characteristics and compare it with the condition of mean values assumptions. Our investigation was based on LIGHTAWE Monte Carlo simulation code with purpose to examine the Gd2O2S:Tb phosphor layer extracted from a mammographic Kodak Min-R 2 Cassette. The GSD was determined via scanning electron microscopy (SEM). Three cases of mean values were taken into account: (i) 1.48 μm obtained calculations of the aforementioned GSD, (ii) 2.50 μm and 7.00 μm taken from previous articles and manufacturer datasheets. Light emission was performed under different irradiation conditions (i. e., light quanta are produced by light source or an X-ray beam) and in terms of light amount and distribution. Our investigation showed that the optical distribution in real GSD was found: (a) sharper than the calculated mean value of the GSD and (b) broader than the mean value taken from the manufacturer datasheet. In particular, the deviation of GSD was found significantly high compared to 7.00 μm mean value. Examining the spatial resolution properties of both conditions, the deviation was around 16.5%, 18.2%, 14.8% assuming that the light source is situated within the phosphor mass, an X-ray beam of 20 keV and X-ray beam of 30 keV, respectively.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Digital Radiography and Breast Imaging · Advanced X-ray and CT Imaging · Radiation Dose and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Radiation detector materials: an overview10.1557/JMR.2008.0319 ↗
2. Scintillator-based flat-panel x-ray imaging detectors10.1889/JSID17.6.535 ↗
3. Developments in electronic portal imaging systems10.1259/bjr/21517185 ↗
4. Modeling the performance characteristics of computed radiography (CR) systems10.1109/TMI.2009.2036995 ↗
5. Light wavelength effects in submicrometer phosphor materials using Mie scattering and Monte Carlo simulation10.1118/1.4821089 ↗
6. Investigating the particle packing of powder phosphors for imaging instrumentation technology: an examination of Gd2O2S:Tb phosphor
7. Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens10.1118/1.596583 ↗
8. A simple model for estimating the particle size dependence of absolute efficiency of fluorescent screens10.1088/0031-9155/44/5/319 ↗
9. Modeling quantum and structure noise of phosphors used in medical x-ray imaging detectors10.1016/S0168-9002(02)01088-4 ↗
10. Analytical and Monte Carlo comparisons on the optical transport mechanisms of powder phosphors10.1016/j.optmat.2018.12.006 ↗
11. Experimental assessment of a phosphor model for estimating the relativeextrinsic efficiency in radioluminescent detectors10.1016/j.ejmp.2020.07.009 ↗
12. Modeling granular phosphor screens by Monte Carlo methods10.1118/1.2372217 ↗
13. Optical diffusion performance of nanophosphor-based materials for use in medical imaging10.1117/1.JBO.17.12.126013 ↗
14. Optical absorption characteristics in the assessment of powder phosphor-based X-ray detectors: from nano to micro scale10.1088/0031-9155/60/22/8885 ↗
15. Optical photon transport in powdered-phosphor scintillators. Part 1. Multiple-scattering and validity of the Boltzmann transport equation
16. Optical photon transport in powdered-phosphor scintillators. Part II. Calculation of single-scattering transport parameters
17. Extension of the GATE Monte-Carlo simulation package to model bioluminescence and fluorescence imaging
18. Rapid Monte Carlo simulation of detector DQE (f)10.1118/1.4865761 ↗
19. Lightawe – case studies of LIGHT spread in powder materials: a Monte Carlo simulation tool for research and educational purposes
20. Diagnostic quality of 50 and 100 μm computed radiography compared with screen-film mammography in operative breast specimens10.1259/bjr/74825285 ↗
21. Luminescence efficiency of calcium tungstate (CaWO4) under X-ray radiation: comparison with Gd2O2S:Tb10.1016/j.measurement.2018.02.027 ↗
22. Role of the activator in the performance of scintillators used in X-ray imaging10.1016/S0720-048X(98)00109-0 ↗
23. Lubberts effect in columnar phosphors10.1118/1.1796151 ↗
24. On the determination of the temperature distribution within the color conversion elements of phosphor converted LEDs10.1038/s41598-017-10114-6 ↗
25. Light emission efficiency and imaging performance of Gd2O2S:Eu powder scintillator under x-ray radiography conditions10.1118/1.3451113 ↗