Glassy carbon electrode modified by gold nanofibers decorated iron metal–organic framework nanocomposite for voltammetric determination of acetaminophen
Source abstract
Abstract
In this work, a nanocomposite containing gold (Au) nanofibers decorated iron-metal–organic framework (Fe-MOF) was successfully synthesized for electrochemical detection of acetaminophen (AAP). The as-synthesized Au@Fe-MOF nanocomposite was confirmed by various characterization techniques. Morphological analysis showed that the Au nanofibers with an average size of less than 10 nm were dispersed on the Fe-MOF. Cyclic voltammetric analysis showed that the Au@Fe-MOF nanocomposite showed well-defined redox peaks with higher current than that of GCE and Fe-MOF. The Au@Fe-MOF/GCE exhibited a linear range, sensitivity, and detection limit of 0.5–18 µM, 4.95 µM/µA/cm2, and 0.12 µM, respectively. The Au@Fe-MOF/GCE showed a very low response for the interference materials. The real sample analysis revealed that the Au@Fe-MOF/GCE showed good recovery towards the AAP in urine and paracetamol. Therefore, the developed sensor can be used for quality control of AAP.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Analytical Methods in Pharmaceuticals · Electrochemical Analysis and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Kushwaha CS, Shukla SK (2020) Electrochemical sensing of paracetamol using iron oxide encapsulated in chitosan-grafted-polyaniline. ACS Appl Polym Mater 2:2252–225910.1021/acsapm.0c00239 ↗
2. Montaseri H, Forbes PBC (2018) Analytical techniques for the determination of acetaminophen—a review. TrAC Trends Anal Chem 108:122–13410.1016/j.trac.2018.08.023 ↗
3. Demir N, Atacan K, Ozmen M, Bas SZ (2020) Design of a new electrochemical sensing system based on MoS2-TiO2/reduced graphene oxide nanocomposite for the detection of paracetamol. New J Chem 44:11759–1176710.1039/D0NJ02298E ↗
4. Mahmoud BG, Khairy M, Rashwan FA, Banks CE (2017) Simultaneous voltammetric determination of acetaminophen and isoniazid (hepatotoxicity-related drugs) utilizing bismuth oxide nanorod modified screen-printed electrochemical sensing platforms. Anal Chem 89:2170–217810.1021/acs.analchem.6b05130 ↗
5. Cernat A, Tertis M, SăndulescuR BF, Cristea A, Cristea C (2015) Electrochemical sensors based on carbon nanomaterials for acetaminophen detection—a review. Anal Chim Acta 886:16–2810.1016/j.aca.2015.05.044 ↗
6. Thi N, Thu A, Duc H, Van DH, Phong NH, Cuong ND, Thi N, Hoan V, Khieu DQ (2018) Electrochemical determination of paracetamol using Fe3O4/reduced graphene-oxide-based electrode. J Nanomater 2018:7619419
7. Verma SK, Das AK, Gantait S, Panwar Y, Kumar V, Brestic M (2022) Green synthesis of carbon-based nanomaterials and their applications in various sectors: a topical review. Carbon Lett 32:365–39310.1007/s42823-021-00294-7 ↗
8. Medetalibeyoğlu H (2021) An investigation on development of a molecular imprinted sensor with graphitic carbon nitride (g-C3N4) quantum dots for detection of acetaminophen. Carbon Lett 31:1237–124810.1007/s42823-021-00247-0 ↗
9. Hudari FF, Duarte EH, Pereira AC, Dall’Antonia LH, Kubota LT, Tarley CRT (2013) Voltammetric method optimized by multi-response assays for the simultaneous measurements of uric acid and acetaminophen in urine in the presence of surfactant using MWCNT paste electrode. J Electroanal Chem 696:52–5810.1016/j.jelechem.2013.01.033 ↗
10. Annadurai K, Sudha V, Murugadoss G, Thangamuthu R (2021) Electrochemical sensor based on hydrothermally prepared nickel oxide for the determination of 4-acetaminophen in paracetamol tablets and human blood serum samples. J Alloy Compd 852:15691110.1016/j.jallcom.2020.156911 ↗
11. Abdelwahab AA, Naggar AH, Abdelmotaleb M, Emran MY (2020) Ruthenium nanoparticles uniformly designed chemically treated graphene oxide nanosheets for simultaneous voltammetric determination of dopamine and acetaminophen. Electroanalysis 32:2156–216510.1002/elan.202060126 ↗
12. Martínez-Sánchez C, Montiel-González F, Rodríguez-González V (2019) Electrochemical sensing of acetaminophen using a practical carbon paste electrode modified with a graphene oxide-Y2O3 nanocomposite. J Taiwan Inst Chem Eng 96:382–38910.1016/j.jtice.2018.12.004 ↗
13. Tang J, Hui ZZ, Hu T, Cheng X, Guo JH, Li ZR, Yu H (2022) A sensitive acetaminophen sensor based on Co metal-organic framework (ZIF-67) and macroporous carbon composite. Rare Met 41:189–19810.1007/s12598-021-01709-0 ↗
14. Cao F, Dong Q, Li C, Chen J, Ma X, Huang Y, Song D, Ji C, Lei Y (2018) Electrochemical sensor for detecting pain reliever/fever reducer drug acetaminophen based on electrospun CeBiOx nanofibers modified screen-printed electrode. Sens Actuators B Chem 256:143–15010.1016/j.snb.2017.09.204 ↗
15. Jin Y, Zhao C, Sun Z, Lin Y, Chen L, Wang D, Shen C (2016) Facile synthesis of Fe-MOF/RGO and its application as a high performance anode in lithium-ion batteries. RSC Adv 6:30763–3076810.1039/C6RA01645F ↗
16. Liu X, Zhou Y, Zhang J, Tang L, Luo L, Zeng G (2017) Iron-containing metal-organic frameworks: structure, synthesis, and applications in environmental remediation. ACS Appl Mater Interfaces 9:20255–2027510.1021/acsami.7b02563 ↗
17. Mahmoud IA, Jiang X, Tan J, Cai Z, Lou X, Wang J, Li Z (2022) Dye-sensitized Fe-MOF nanosheets as visible-light driven photocatalyst for high efficient photocatalytic CO2 reduction. J Colloid Interface Sci 607:1180–118810.1016/j.jcis.2021.09.014 ↗
18. Soni S, Bajpai PK, Arora C (2018) A review on metal-organic framework: synthesis, properties and application. Charact Appl Nanomater 2:1–2010.24294/can.v2i2.551 ↗
19. Yang LM, Fang GY, Ma J, Ganz E, Han SS (2014) Bandgap engineering of paradigm MOF-5. Crys Grow Design 14:2532–254110.1021/cg500243s ↗
20. Pattappan D, Kavya KV, Vargheese S, Rajendra Kumar RT, Haldorai Y (2022) Graphitic carbon nitride/NH2-MIL-101(Fe) composite for environmental remediation: visible light-assisted photocatalytic degradation of acetaminophen and reduction of hexavalent chromium. Chemosphere 286:13187510.1016/j.chemosphere.2021.131875 ↗
21. Barbosa ADS, Julião D, Fernandes DM, Peixoto AF, Freire C, de Castro B, Granadeiro CM, Balula SS, Cunha-Silva L (2017) Catalytic performance and electrochemical behaviour of metal-organic frameworks: MIL-101(Fe) versus NH2-MIL-101(Fe). Polyhedron 127:464–47010.1016/j.poly.2016.10.032 ↗
22. Rengaraj A, Haldorai Y, Hwang SK, Lee E, Oh M-W, Jeon T-J, Han Y-K, Huh YS (2019) A protamine-conjugated gold decorated graphene oxide composite as an electrochemical platform for heparin detection. Bioelectrochem 128:211–21710.1016/j.bioelechem.2019.04.002 ↗
23. Araya T, Jia M, Yang J, Zhao P, Cai K, Ma W, Huang Y (2017) Resin modified MIL-53 (Fe) MOF for improvement of photocatalytic performance. Appl Catal B Environ 203:768–77710.1016/j.apcatb.2016.10.072 ↗
24. Pattappan D, Vargheese S, Kavya KV, Rajendra Kumar RT, Haldorai Y (2022) Metal-organic frameworks with different oxidation states of metal nodes and aminoterephthalic acid ligand for degradation of rhodamine B under solar light. Chemosphere 286:13172610.1016/j.chemosphere.2021.131726 ↗
25. Bajpai VK, Haldorai Y, Khan I, Sonwal S, Singh MP, Yadav S, Paray BA, Jan BL, Kang S-M, Huh YS, Han Y-K, Shukla S (2021) Au@Zr-based metal-organic framework composite as an immunosensing platform for determination of hepatitis B virus surface antigen. Microchim Acta 188:36510.1007/s00604-021-05022-6 ↗
26. Dinesh M, Muthumalai K, Haldorai Y, Thangavelu Rajendra Kumar R (2020) MoS2 nanosheets decorated multi-walled carbon nanotube composite electrocatalyst for 4-nitrophenol detection and hydrogen evolution reaction. Electroanalysis 32:2571–258010.1002/elan.202060351 ↗
27. LiZY GDY, Wu ZY, Zhao S (2020) Simultaneous electrochemical detection of levodapa, paracetamol and l-tyrosine-based on multi-walled carbon nanotubes. RSC Adv 10:14218–1422410.1039/D0RA00290A ↗
28. Pereira SAC, Silva ND, Porto S, Pereira CA (2020) development of electrochemical biosensor based on nanostructured carbon materials for paracetamol determination. Electroanalysis 32:1905–191310.1002/elan.201900117 ↗
29. Shi L, Wang Z, Wu N, Chen X, Yang G, Liu W (2020) Reduced graphene/polydopamine-supported Au@Pt/Au nanoparticles for electrochemical detection of acetaminophen. Int J Electrochem Sci 15:3922–393410.20964/2020.05.78 ↗
30. Emran MY, Talat E, El-Safty SA, Shenashen MA, Saad EM (2021) Influence of hollow sphere surface heterogeneity and geometry of N-doped carbon on sensitive monitoring of acetaminophen in human fluids and pharmaceutical products. New J Chem 45:5452–546210.1039/D0NJ05442A ↗
31. Duraisamy V, Sudha V, Annadurai K, Senthil Kumar SM, Thangamuthu R (2021) Ultrasensitive simultaneous detection of ascorbic acid, dopamine, uric acid and acetaminophen on a graphitized porous carbon-modified electrode. New J Chem 45:1863–187510.1039/D0NJ04806B ↗
32. Camargo JR, Andreotti IAA, Kalinke C, Henrique JM, Bonacin JA, Janegitz BC (2020) Waterproof paper as a new substrate to construct a disposable sensor for the electrochemical determination of paracetamol and melatonin. Talanta 208:12045810.1016/j.talanta.2019.120458 ↗
33. Yadav M, Ganesan V, Maiti B, Gupta R, Sonkar PK, Yadav DK, Walcarius A (2019) sensitive determination of acetaminophen in the presence of dopamine and pyridoxine facilitated by their extent of interaction with single-walled carbon nanotubes. Electroanalysis 31:2472–247910.1002/elan.201900178 ↗