Design and testing of hydrophobic core/hydrophilic shell nano/micro particles for drug-eluting stent coating
Source abstract
Abstract
In this study, we designed a novel drug-eluting coating for vascular implants consisting of a core coating of the anti-proliferative drug docetaxel (DTX) and a shell coating of the platelet glycoprotein IIb/IIIa receptor monoclonal antibody SZ-21. The core/shell structure was sprayed onto the surface of 316L stainless steel stents using a coaxial electrospray process with the aim of creating a coating that exhibited a differential release of the two drugs. The prepared stents displayed a uniform coating consisting of nano/micro particles. In vitro drug release experiments were performed, and we demonstrated that a biphasic mathematical model was capable of capturing the data, indicating that the release of the two drugs conformed to a diffusion-controlled release system. We demonstrated that our coating was capable of inhibiting the adhesion and activation of platelets, as well as the proliferation and migration of smooth muscle cells (SMCs), indicating its good biocompatibility and anti-proliferation qualities. In an in vivo porcine coronary artery model, the SZ-21/DTX drug-loaded hydrophobic core/hydrophilic shell particle coating stents were observed to promote re-endothelialization and inhibit neointimal hyperplasia. This core/shell particle-coated stent may serve as part of a new strategy for the differential release of different functional drugs to sequentially target thrombosis and in-stent restenosis during the vascular repair process and ensure rapid re-endothelialization in the field of cardiovascular disease. A cardiovascular stent that releases drugs to prevent artery blockage has been developed by researchers in China, the United Kingdom and Italy. A common treatment for cardiovascular disease, coronary stents ensure blood flow by keeping arteries open. Many of these stents also release drugs to repair the damage that these devices can do to surrounding tissue. Such damage includes the proliferation of smooth muscle cells that build up as scar tissue on the inside of the artery. Guixue Wang and Tieying Yin from the Bioengineering College of Chongqing University, China, and co-workers sprayed stainless-steel stents with particles consisting of a shell of the anti-proliferative drug docetaxel and an antibody core which prevents the formation of blood clots. Tests of their device using a pig coronary artery showed that smooth muscle cell proliferation was inhibited. Hydrophobic core/hydrophilic shell platelet glycoprotein IIb/IIIa receptor monoclonal antibody (SZ-21)/docetaxel (DTX) dual-drug loaded stents exhibiting a uniform coating of nano/micro particles using coaxial electrospray were prepared. Experimental data combined with a biphasic mathematical model indicated the release of the two drugs conformed to a diffusion-controlled release system. The core/shell SZ-21/DTX dual-drug loaded stents showed good blood and cell compatibility, promoted re-endothelialization in vivo and reduced in-stent restenosis in porcine coronary arteries. The coaxial electrospray technique is a one-step and effective technique for stent coating with multiple drugs and has great potential for helping to create the enhanced implants of the future.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrohydrodynamics and Fluid Dynamics · Nanofabrication and Lithography Techniques · Coronary Interventions and Diagnostics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (65)
Show source-provided references
1. O’brien, B. & Carroll, W. The evolution of cardiovascular stent materials and surfaces in response to clinical drivers: a review. Acta Biomater. 5, 945–958 (2009).10.1016/j.actbio.2008.11.012 ↗
2. Bønaa, K. H. et al. Drug-eluting or bare-metal stents for coronary artery disease. New Engl. J. Med. 375, 1242–1252 (2016).10.1056/NEJMoa1607991 ↗
3. Douglas, P. S. et al. Clinical effectiveness of coronary stents in elderly persons: results from 262,700 Medicare patients in the American College of Cardiology-National Cardiovascular Data Registry. J. Am. Coll. Cardiol. 53, 1629–1641 (2009).10.1016/j.jacc.2009.03.005 ↗
4. Erruys, P. W. et al. 5-year clinical outcomes of the ARTS II (Arterial Revascularization Therapies Study II) of the sirolimus-eluting stent in the treatment of patients with multivessel de novo coronary artery lesions. J. Am. Coll. Cardiol. 55, 1093–1101 (2010).10.1016/j.jacc.2009.11.049 ↗
5. Stettler, C. et al. Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis. Lancet 370, 937–948 (2007).10.1016/S0140-6736(07)61444-5 ↗
6. Camenzind, E., Steg, P. G. & Wijns, W. Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern. Circulation 115, 1440–1455 (2007).10.1161/CIRCULATIONAHA.106.666800 ↗
7. Baber, U. et al. Coronary thrombosis and major bleeding after PCI with drug-eluting stents: risk scores from PARIS. J. Am. Coll. Cardiol. 67, 2224–2234 (2016).10.1016/j.jacc.2016.02.064 ↗
8. Inoue, T. et al. Comparison of activation process of platelets and neutrophils after coronary stent implantation versus balloon angioplasty for stable angina pectoris. Am. J. Cardiol. 86, 1057–1062 (2000).10.1016/S0002-9149(00)01159-0 ↗
9. Park, E. S. et al. Inhibitory effects of docetaxel on platelet-derived growth factor (PDGF)-BB-induced proliferation of vascular smooth muscle cells through blocking PDGF-receptor β phosphorylation. J. Pharmacol. Sci. 116, 204–213 (2011).10.1254/jphs.10276FP ↗
10. Yasuda, S. et al. Local delivery of low-dose docetaxel, a novel microtubule polymerizing agent, reduces neointimal hyperplasia in a balloon-injured rabbit iliac artery model. Cardiovasc Res. 53, 481–486 (2002).10.1016/S0008-6363(01)00499-0 ↗
11. Skinner, M. P. Thrombosis and thrombolysis: platelet membrane glycoproteins. Heart Lung Circ. 16, 176–179 (2007).10.1016/j.hlc.2007.03.004 ↗
12. Aggarwal, R. K. et al. Antithrombotic potential of polymer-coated stents eluting platelet glycoprotein IIb/IIIa receptor antibody. Circulation 94, 3311–3317 (1996).10.1161/01.CIR.94.12.3311 ↗
13. Boersma, E. et al. Platelet glycoprotein IIb/IIIa inhibitors in acute coronary syndromes: a meta-analysis of all major randomised clinical trials. Lancet 360, 342–343 (2002).10.1016/S0140-6736(02)09532-6 ↗
14. Lim, K. S. et al. Effect of polymer-free TiO2stent coated with abciximab or alpha lipoic acid in porcine coronary restenosis model. J. Cardiol. 64, 409–418 (2014).10.1016/j.jjcc.2014.02.015 ↗
15. Freiberg, S. & Zhu, X. X. Polymer microspheres for controlled drug release. Int J. Pharm. 282, 1–18 (2004).10.1016/j.ijpharm.2004.04.013 ↗
16. Arsiwala, A., Desai, P. & Patravale, V. Recent advances in micro/nanoscale biomedical implants. J. Control Release 189, 25–45 (2014).10.1016/j.jconrel.2014.06.021 ↗
17. Natarajan, J. V., Nugraha, C., Xu, W. N. & Venkatraman, S. Sustained-release from nanocarriers: a review. J. Control Release 193, 122–138 (2014).10.1016/j.jconrel.2014.05.029 ↗
18. Yang, J. et al. The prevention of restenosis in vivo with a VEGF gene and paclitaxel co-eluting stent. Biomaterials 34, 1635–1643 (2013).10.1016/j.biomaterials.2012.11.006 ↗
19. Kanzer, J. et al. In situ formation of nanoparticles upon dispersion of melt extrudate formulations in aqueous medium assessed by asymmetrical flow field-flow fractionation. J. Pharm. Biomed. 53, 359–365 (2010).10.1016/j.jpba.2010.04.012 ↗
20. Zhang, J., Lv, H., Jiang, K. & Gao, Y. Enhanced bioavailability after oral and pulmonary administration of baicalein nanocrystal. Int J. Pharm. 420, 180–188 (2011).10.1016/j.ijpharm.2011.08.023 ↗
21. Müller, R. H., Mäder, K. & Gohla, S. Solid lipid nanoparticles (SLN) for controlled drug delivery - a review of the state of the art. Eur. J. Pharm. Biopharm. 45, 149–155 (1998).10.1016/S0939-6411(97)00150-1 ↗
22. Danhier, F. et al. Paclitaxel-loaded PEGylated PLGA-based nanoparticles: in vitro and in vivo evaluation. J. Control Release 133, 11–17 (2009).10.1016/j.jconrel.2008.09.086 ↗
23. Thian, E. S. et al. Electrospray deposition of nanohydroxyapatite coatings: a strategy to mimic bone apatite mineral. Thin Solid Films. 519, 2328–2331 (2011).10.1016/j.tsf.2010.11.035 ↗
24. Almería, B., Fahmy, T. M. & Gomez, A. A multiplexed electrospray process for single-step synthesis of stabilized polymer particles for drug delivery. J. Control Release 154, 203–210 (2011).10.1016/j.jconrel.2011.05.018 ↗
25. Dong, M. K. et al. Fabrication and controlled release of electrosprayed ReoPro-loaded metal surface for vascular stent. Macromol. Res. 19, 501–506 (2011).10.1007/s13233-011-0210-8 ↗
26. Zamani, M., Prabhakaran, M. P., Varshosaz, J., Mhaisalkar, P. S. & Ramakrishna, S. Electrosprayed Montelukast/poly (lactic-co-glycolic acid) particle based coating: a new therapeutic approach towards the prevention of in-stent restenosis. Acta Biomater. 42, 316–328 (2016).10.1016/j.actbio.2016.07.007 ↗
27. Sun, D. et al. Coronary drug-eluting stents: from design optimization to newer strategies. J. Biomed. Mater. Res A. 102, 1625–1640 (2014).10.1002/jbm.a.34806 ↗
28. Tan, A., Alavijeh, M. S. & Seifalian, A. M. Next generation stent coatings: convergence of biotechnology and nanotechnology. Trends Biotechnol. 30, 406–409 (2012).10.1016/j.tibtech.2012.05.004 ↗
29. Ding N. US patent 5980972 (1999).
30. Meng, S. et al. The effect of a layer-by-layer chitosan-heparin coating on the re-endothelialization and coagulation properties of a coronary stent system. Biomaterials 30, 2276–2283 (2009).10.1016/j.biomaterials.2008.12.075 ↗
31. Cao, Y., Wang, B. C., Wang, Y. Z. & Lou, D. S. Polymer-controlled core–shell nanoparticles: anovel strategy for sequential drug release. RSC Adv. 4, 30430–30439 (2014).10.1039/C4RA03610G ↗
32. An, G. Y., Dong, N. Z., Shao, B. J., Zhu, M. Q. & Ruan, C. G. Expression and characterization of the ScFv fragment of antiplatelet GPIIIa monoclonal antibody SZ-21. Thromb. Res. 105, 331–337 (2002).10.1016/S0049-3848(02)00033-6 ↗
33. Xi, X. et al. Competitive binding of a monoclonal antibody SZ-21 with anti-PLA1 antibodies and its potential for clinical application. Nouv. Rev. Fr. Hematol. 34, 239–242 (1992).
34. Saylor, D. M., Adidharma, L., Fisher, J. W. & Brown, R. P. A biokinetic model for nickel released from cardiovascular devices. Regul. Toxicol. Pharm. 80, 1–8 (2016).10.1016/j.yrtph.2016.05.019 ↗
35. Wang, H. G. et al. Biofunctionalization of titanium surface with multilayer films modified by heparin-VEGF-fibronectin complex to improve endothelial cell proliferation and blood compatibility. J. Biomed. Mater. Res A. 101, 413–420 (2013).10.1002/jbm.a.34339 ↗
36. Gawaz, M. et al. Changes in membrane glycoproteins of circulating platelets after coronary stent implantation. Heart 76, 166–172 (1996).10.1136/hrt.76.2.166 ↗
37. Ko, T. M., Lin, J. C. & Cooper, S. L. Surface characterization and platelet adhesion studies of plasma-sulphonated polyethylene. Biomaterials 14, 657–664 (1993).10.1016/0142-9612(93)90064-9 ↗
38. Wu, X. et al. Re-Re-endothelialization Study on Endovascular Stents Seeded by Endothelial Cells through Up- or Downregulation of VEGF. ACS Appl. Mater. Interfaces 8, 7578–7589 (2016).10.1021/acsami.6b00152 ↗
39. Garg, S. & Serruys, P. W. Coronary stents: current status. J. Am. Coll. Cardiol. 56, S1–S42 (2010).10.1016/j.jacc.2010.06.007 ↗
40. Lee, J. M. et al. Comparison among drug-eluting balloon, drug-eluting stent, and plain balloon angioplasty for the treatment of in-stent restenosis: a network meta-analysis of 11 randomized, controlled trials. JACC-Cardiovasc Inte 8, 382–394 (2015).10.1016/j.jcin.2014.09.023 ↗
41. Puricel, S. et al. Comparison of everolimus- and biolimus-eluting coronary stents witheverolimus-eluting bioresorbable vascular scaffolds. J. Am. Coll. Cardiol. 65, 791–801 (2015).10.1016/j.jacc.2014.12.017 ↗
42. Wilensky, R. L. et al. Vascular injury, repair, and restenosis after percutaneous transluminal angioplasty in the atherosclerotic rabbit. Circulation 92, 2995–3005 (1995).10.1161/01.CIR.92.10.2995 ↗
43. Wykrzykowska, J. J., Onuma, Y. & Serruys, P. W. Advances in stent drug delivery: the future is in bioabsorbable stents. Expert Opin. Drug Del. 6, 113–126 (2009).10.1517/17425240802668495 ↗
44. Ali, M. T. et al. A novel CX3CR1 antagonist eluting stent reduces stenosis by targeting inflammation. Biomaterials 69, 22–29 (2015).10.1016/j.biomaterials.2015.07.059 ↗
45. Slee, J. B. et al. Enhanced biocompatibility of CD47-functionalized vascular stents. Biomaterials 87, 82–92 (2016).10.1016/j.biomaterials.2016.02.008 ↗
46. Yang, Z. et al. Nitric oxide producing coating mimicking endothelium function for multifunctional vascular stents. Biomaterials 63, 80–92 (2015).10.1016/j.biomaterials.2015.06.016 ↗
47. Zhang, H., Ren, K. F., Chang, H., Wang, J. L. & Ji, J. Surface-mediated transfection of a pDNA vector encoding short hairpin RNA to downregulate TGF-beta1 expression for the prevention of in-stent restenosis. Biomaterials 116, 95–105 (2017).10.1016/j.biomaterials.2016.11.042 ↗
48. Sweeney, C. J. et al. The antiangiogenic property of docetaxel is synergistic with a recombinant humanized monoclonal antibody against vascular endothelial growth factor or 2-methoxyestradiol but antagonized by endothelial growth factors. Cancer Res. 61, 3369–3372 (2001).
49. Nakano, T., Goto, K. & Wakabayashi, I. Docetaxel inhibits cyclooxygenase-2 induction in vascular smooth muscle cells. Eur. J. Pharmacol. 654, 150–154 (2011).10.1016/j.ejphar.2010.12.009 ↗
50. Bierhalz, A. & Moraes, Â. Composite membranes of alginate and chitosan reinforced with cotton or linen fibers incorporating epidermal growth factor. Mat. Sci. Eng. A-Struc. 76, 287–294 (2017).10.1016/j.msec.2017.03.015 ↗
51. Lee, S. et al. Enhanced therapeutic neovascularization by CD31-expressing cells and embryonic stem cell-derived endothelial cells engineered with chitosan hydrogel containing VEGF-releasing microtubes. Biomaterials 63, 158–167 (2015).10.1016/j.biomaterials.2015.06.009 ↗
52. Heldman, A. W. et al. Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis. Circulation 103, 2289–2295 (2001).10.1161/01.CIR.103.18.2289 ↗
53. Pan, C. J., Tang, J. J., Weng, Y. J., Wang, J. & Huang, N. Preparation, characterization and anticoagulation of curcumin-eluting controlled biodegradable coating stents. J. Control Release 116, 42–49 (2006).10.1016/j.jconrel.2006.08.023 ↗
54. Liu, S. J., Chiang, F. J., Hsiao, C. Y., Kau, Y. C. & Liu, K. S. Fabrication of balloon-expandable self-lock drug-eluting polycaprolactone stents using micro-injection molding and spray coating techniques. Ann. Biomed. Eng. 38, 3185–3194 (2010).10.1007/s10439-010-0075-6 ↗
55. Hossfeld, S. et al. Bioactive coronary stent coating based on layer-by-layer technology for sirna release. Acta Biomater. 9, 6741–6752 (2013).10.1016/j.actbio.2013.01.013 ↗
56. Song, C. L. et al. Study of novel coating strategy for coronary stents: simutaneous coating of vegf and anti- CD34 antibody. Rev. Bras. Cir. Cardiovasc. 30, 159–163 (2015).
57. Wang G. X., Du R. L., Yin T. Y., Wang Y. Z. & Rao Q. CN patent 103566414 B (2016).
58. Zamani, M., Prabhakaran, M. P. & Ramakrishna, S. Advances in drug delivery via electrospun and electrosprayed nanomaterials. Int J. Nanomed. 8, 2997–2307 (2013).
59. O’Brien, B., Zafar, H., Ibrahim, A., Zafar, J. & Sharif, F. Coronary stent materials and coatings: a technology and performance update. Ann. Biomed. Eng. 44, 1–13 (2015).
60. Kolandaivelu, K. et al. Ultra-hydrophilic stent platforms promote early vascular healing and minimise late tissue response: a potential alternative to second-generation drug-eluting stents. Eurointervention 12, 17 (2016).
61. Lee, Y. H., Mei, F., Bai, M. Y., Zhao, S. & Chen, D. R. Release profile characteristics of biodegradable-polymer-coated drug particles fabricated by dual-capillary electrospray. J. Control Release 145, 58–65 (2010).10.1016/j.jconrel.2010.03.014 ↗
62. Mcginty, S. & Pontrelli, G. A general model of coupled drug release and tissue absorption for drug delivery devices. J. Control Release 217, 327–336 (2015).10.1016/j.jconrel.2015.09.025 ↗
63. Riegger, J. et al. Histopathological evaluation of thrombus in patients presenting with stent thrombosis. a multicenter european study: a report of the prevention of late stent thrombosis by an interdisciplinary global european effort consortium. Eur. Heart J. 37, 1538–1549 (2015).
64. Jang, S., Lim, K. S., Song, J. E. & Jeong, M. H. Effect of non-polymer titanium dioxide thin film coated stent with heparin in porcine coronary restenosis model. J. Am. Coll. Cardioy 67, 606 (2016).10.1016/S0735-1097(16)30607-6 ↗
65. Ma, X. et al. Delayed re-endothelialization with rapamycin-coated stents is rescued by the addition of a glycogen synthase kinase-3beta inhibitor. Cardiovasc Res 86, 338–345 (2010).10.1093/cvr/cvq047 ↗