NONDESTRUCTIVE EVALUATION OF CERAMIC COMPONENTS BY γ-RAY CT
Source abstract
Abstract
Abstract Some results of γ-ray Computed Tomography (CT) examination of ceramic parts in various stages of the manufacturing process are presented in this paper. The ceramic samples were prepared by injection molding and examined in three stages: after injection-molding, after sintering and after HIPing. CT tests were performed at AECL Research, Chalk River Laboratories. The uniformity of the material distribution in ceramic parts was measured by measuring density gradients in CT images, with an accuracy between 0.2% and 0.5% in various scans. The results demonstrate that the CT technique is very useful, particularly for monitoring changes in material distribution during various stages of the fabrication process and for providing comparisons between technologically different processes. KEY WORDS: γ-ray computed tomographyceramicsdensity fluctuations Notes *Shoichi Rokugawa, Shun-ichi Usui and Barbara D. Sawicka carried out the research and prepared this paper on behalf of Atomic Energy of Canada Limited.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications · Radiation Shielding Materials Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. Sawicka B.D. · Journal of Canadian Society for Nondestructive Testing · 1989 · 10 · 24
2. Sawicka B.D. · Nucl. Instr. Methods · 1988 · 263 · 52510.1016/0168-9002(88)90997-7 ↗
3. Sawicka B.D. · 1987 · 6 · 42110.1007/978-1-4613-1893-4_48 ↗
4. Sawicka B.D. · 1988 · 9
5. Sawicka B.D. · Nucl. Instr. Methods · 1990 · 299 · 46810.1016/0168-9002(90)90827-S ↗
6. Taylor T. · Nucl. Instr. Methods · 1986 · 242 · 60310.1016/0168-9002(86)90474-2 ↗
7. Newton T.H. · 1981 · 5