NONDESTRUCTIVE TESTING OF CERAMIC COATINGS ON STEEL BY PHOTOACOUSTIC, PHOTOTHERMAL AND HIGH-FREQUENCY ULTRASOUND TECHNIQUES

D.H. KIM, U. NETZELMANN

Publisher page

Abstract

Abstract Adhesion of tungsten carbide coatings with a thickness of about 300 μm on steel subtrates has been tested by photoacoustic microscopy at 33.8 kHz, by photothermal radiometry at 20-200 Hz and by high-frequency ultrasound measurements at 80 MHz. Delaminated regions of the coating were detected in good agreement with the photoacoustic and the ultrasound technique.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Thermography and Photoacoustic Techniques · Ultrasonics and Acoustic Wave Propagation · Photoacoustic and Ultrasonic Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (8)

Show source-provided references
1. 10.1063/1.32804510.1063/1.328045 ↗
2. 10.1007/BF0131368610.1007/BF01313686 ↗
3. Ringermachcr H.I. · 1990 · 9 · 471
4. Pangraz S. · 1991 · 18
5. 10.1063/1.34332010.1063/1.343320 ↗
6. 10.1063/1.32229610.1063/1.322296 ↗
7. F. Lepoutre , D. Fournier and A.C. Boccara , ‘ Influence of 3-D effects of the contrast in photothermal imaging’, in ‘Nondestructive characterization of materials ’, Vol. 2 , J.F. Bussiere et al. (eds. ) ( Plenum Press , New-York 1987 ), p. 771 .10.1007/978-1-4684-5338-6_80 ↗