A fast laser ultrasonic SAFT method with sparse scanning data and F-K based interpolation
Source abstract
Abstract
Laser ultrasonic SAFT can be applied for noncontact testing and imaging of defects in structures. However, due to the large demand for signal data by laser scanning, the time consumption of this method would be relatively long. To address this problem, this paper proposes a fast LU-SAFT method with sparse scanning data and F-K based interpolation. It aims to reduce the inspection time but without decreasing the imaging resolution. First, the method determines the minimum number of scanning sparse points using simulation. Then the F-K interpolation method is utilised to recover the full-field unscanned point signal from the sparse scan data. Finally, the reconstructed signal is used for SAFT image reconstruction of the defect. The experimental results show that, for the same scanning area, the proposed method in this paper reduces the number of scanning points by 87.5% and shortens the scanning time by 86.0% compared to conventional LU-SAFT point-by-point scanning. Additionally, the signal-to-noise ratio of the defective SAFT imaging decreases by only about 7.9%.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Geophysical Methods and Applications · Flow Measurement and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Xi’an Jiaotong University
Funding
National Key Research and Development Program of China · National Natural Science Foundation of China
References (19)
Show source-provided references
1. Li XK. Research on key technology of image detection of surface defects of bridge cables [D]. Chongqing: Chongqing University; 2014.
2. 10.1080/10589759.2024.235115610.1080/10589759.2024.2351156 ↗
3. 10.1088/0964-1726/23/9/09501910.1088/0964-1726/23/9/095019 ↗
4. 10.1016/j.ultras.2008.06.00210.1016/j.ultras.2008.06.002 ↗
5. 10.1364/OE.17.01559210.1364/OE.17.015592 ↗
6. Li HY, Zhi BL, Pan QH, et al. Photoacoustic detection method for depth of surface narrow defects. Acta Optica Sin. 2022;42(2):0212001.
7. Tan H, Chen YX, Jin Y, et al. Laser ultrasonic real-time monitoring method for solidification state of butylated hydroxy lining. Acta Optica Sin. 2022;42(8):0814004.
8. 10.1016/S0041-624X(02)00256-110.1016/S0041-624X(02)00256-1 ↗
9. 10.1080/10589759.2021.199848910.1080/10589759.2021.1998489 ↗
10. 10.1016/j.pacs.2022.10037010.1016/j.pacs.2022.100370 ↗
11. 10.1016/j.apacoust.2021.10795610.1016/j.apacoust.2021.107956 ↗
12. 10.1088/1361-665X/aa742810.1088/1361-665X/aa7428 ↗
13. 10.1016/j.ultras.2022.10683210.1016/j.ultras.2022.106832 ↗
14. 10.1016/j.measurement.2022.11169010.1016/j.measurement.2022.111690 ↗
15. He Z, Ying K, Dai L, et al. Fast laser ultrasonic synthetic aperture focusing technology based on compressed Sensing. Chin J Lasers. 2024;51(2):0201004.
16. 10.1111/j.1365-2478.2006.00580.x10.1111/j.1365-2478.2006.00580.x ↗
17. 10.1190/1.144309610.1190/1.1443096 ↗
18. 10.1109/APSAR46974.2019.904825910.1109/APSAR46974.2019.9048259 ↗
19. 10.1109/TUFFC.2011.190410.1109/TUFFC.2011.1904 ↗