journal article·2026-01-02

A new type of neutron computed laminography scanning method and centre of rotation calibration algorithm for plate-like components

Qiang Lin, Zeming Ma, Xiangfeng Zhang, Linfeng He, Wenjian Wang, Haohao Ding, Shuyue Zhang, Min Yang

Publisher page

Abstract

Neutron computed laminography (CL) is a special neutron tomographic imaging technology for plate-like components. The neutron beam is considered to be parallel, and the projection image has geometric unsharpness artefact, which reduces the spatial resolution of reconstructed image. It is an effective measure to improve the spatial resolution by making sample close to the imaging plane under the CL scanning mode. Therefore, a new type of neutron CL (NTNCL) scanning mode was designed: the imaging plane was adjusted to be parallel to the sample carrying disc, so that the sample was close to the imaging plane during CL scanning. For the NTNCL scanning mode, the FBP (filtered back-projection) reconstruction algorithm and the accurate calibration algorithm of centre of rotation (COR) were designed. Based on the China Advanced Research Reactor (CARR), a NTNCL tomography experiment of a plate-like copper foam sample with glue inside was carried out. Computer simulation results showed that the NTNCL scanning mode, the proposed reconstruction algorithm and the COR calibration algorithm could effectively improve the reconstructed image resolution of plate-like components. Moreover, the experimental results further verified the sensitivity and effectiveness of neutron CL imaging for detection of viscose material.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Nuclear Physics and Applications · Advanced X-ray Imaging Techniques · Medical Imaging Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Southwest Jiaotong University

Shougang Mining Corporation

China Institute of Atomic Energy

Beihang University

Funding

National Natural Science Foundation of China · Natural Science Foundation of Sichuan Province · National Key R&D Program of China · China Postdoctoral Science Foundation

References (46)

Show source-provided references
1. 10.1080/10589759.2022.208654710.1080/10589759.2022.2086547 ↗
2. 10.2138/rmg.2006.63.1710.2138/rmg.2006.63.17 ↗
3. 10.1080/10589759.2022.209113310.1080/10589759.2022.2091133 ↗
4. 10.1080/10589759.2022.207586410.1080/10589759.2022.2075864 ↗
5. 10.1080/10589759.2020.177457910.1080/10589759.2020.1774579 ↗
6. 10.1038/s41467-019-13943-310.1038/s41467-019-13943-3 ↗
7. 10.1080/1058975029001354110.1080/10589750290013541 ↗
8. 10.1080/10589759.2021.199028410.1080/10589759.2021.1990284 ↗
9. 10.1016/j.nima.2011.01.11410.1016/j.nima.2011.01.114 ↗
10. 10.1016/j.ndteint.2014.02.00410.1016/j.ndteint.2014.02.004 ↗
11. Gondrom S, Schropfer S. Digital computed laminography and tomosynthesis-functional principles and industrial applications. J Nondestr Test Ultrason. 1999;7(2):15–17.
12. 10.1063/1.359656610.1063/1.3596566 ↗
13. 10.1039/c4ay02014f10.1039/c4ay02014f ↗
14. 10.1109/acssc.2017.833568610.1109/acssc.2017.8335686 ↗
15. 10.7566/jpscp.33.01106510.7566/jpscp.33.011065 ↗
16. 10.5104/jiepeng.15.e21-013-110.5104/jiepeng.15.e21-013-1 ↗
17. 10.1007/s11104-021-05120-710.1007/s11104-021-05120-7 ↗
18. 10.1007/978-1-4613-0817-110.1007/978-1-4613-0817-1 ↗
19. 10.1088/1361-6501/aafcae10.1088/1361-6501/aafcae ↗
20. 10.1016/j.net.2020.11.02110.1016/j.net.2020.11.021 ↗
21. 10.1016/j.ndteint.2020.10222210.1016/j.ndteint.2020.102222 ↗
22. 10.1117/1.343062910.1117/1.3430629 ↗
23. 10.1007/s11431-010-4012-610.1007/s11431-010-4012-6 ↗
24. 10.1109/tns.2021.311799310.1109/tns.2021.3117993 ↗
25. 10.1016/j.ndteint.2022.10271210.1016/j.ndteint.2022.102712 ↗
26. 10.1166/jmihi.2014.127910.1166/jmihi.2014.1279 ↗
27. 10.1088/1674-1137/36/8/01710.1088/1674-1137/36/8/017 ↗
28. 10.1364/OE.22.01774510.1364/OE.22.017745 ↗
29. Cho S, Park M, Cho G, et al. Noncircular scanning trajectory for sparse-view computed laminography. In: 6th Conference on Industrial Computed Tomography (iCT 2016); Wels, Austria; 2016.
30. Park M, Lee M, Kim K, et al. Scanning parameter optimization for inspection of welding defects in X-ray linear laminography. In: 7th Conference on Industrial Computed Tomography (iCT 2017); Leuven, Belgium; 2017.
31. 10.1109/ICTAI50040.2020.0009910.1109/ICTAI50040.2020.00099 ↗
32. 10.1109/ICCEIC64099.2024.1077552910.1109/ICCEIC64099.2024.10775529 ↗
33. 10.1117/1.JEI.23.5.05301810.1117/1.JEI.23.5.053018 ↗
34. 10.1016/j.ndteint.2012.08.00510.1016/j.ndteint.2012.08.005 ↗
35. 10.1117/12.56044010.1117/12.560440 ↗
36. 10.1117/1.221471710.1117/1.2214717 ↗
37. 10.1016/j.neucom.2012.08.06610.1016/j.neucom.2012.08.066 ↗
38. 10.1109/23.5586610.1109/23.55866 ↗
39. 10.1016/j.phpro.2017.06.04110.1016/j.phpro.2017.06.041 ↗
40. 10.1016/j.nima.2023.16850510.1016/j.nima.2023.168505 ↗
41. 10.1364/JOSAA.1.00061210.1364/JOSAA.1.000612 ↗
42. 10.1109/TSMC.1979.431007610.1109/TSMC.1979.4310076 ↗
43. 10.1088/2057-1976/2/5/05501010.1088/2057-1976/2/5/055010 ↗
44. 10.1016/j.ijheatmasstransfer.2019.11872610.1016/j.ijheatmasstransfer.2019.118726 ↗
45. 10.3389/fmats.2021.66521910.3389/fmats.2021.665219 ↗
46. 10.1016/j.rinp.2020.10365510.1016/j.rinp.2020.103655 ↗