journal article·2018-04-03

Low sidelobe level and high time resolution for metallic ultrasonic testing with linear-chirp-Golay coded excitation

Jiaying Zhang, Tie Gang, Chaofeng Ye, Sen Cong

Publisher page

Abstract

Linear-chirp-Golay (LCG)-coded excitation combined with pulse compression is proposed in this paper to improve the time resolution and suppress sidelobe in ultrasonic testing. The LCG-coded excitation is binary complementary pair Golay signal with linear-chirp signal applied on every sub pulse. Compared with conventional excitation which is a common ultrasonic testing method using a brief narrow pulse as exciting signal, the performances of LCG-coded excitation, in terms of time resolution improvement and sidelobe suppression, are studied via numerical and experimental investigations. The numerical simulations are implemented using Matlab K-wave toolbox. It is seen from the simulation results that time resolution of LCG excitation is 35.5% higher and peak sidelobe level (PSL) is 57.6 dB lower than linear-chirp excitation with 2.4 MHz chirp bandwidth and 3 μs time duration. In the B-scan experiment, time resolution of LCG excitation is higher and PSL is lower than conventional brief pulse excitation and chirp excitation. In terms of time resolution, LCG-coded signal has better performance than chirp signal. Moreover, the impact of chirp bandwidth on LCG-coded signal is less than that on chirp signal. In addition, the sidelobe of LCG-coded signal is lower than that of chirp signal with pulse compression.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Non-Destructive Testing Techniques · Photoacoustic and Ultrasonic Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin, China

Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, USA

Funding

National Natural Science Foundation of China

References (20)

Show source-provided references
1. 10.1016/0041-624X(78)90072-010.1016/0041-624X(78)90072-0 ↗
2. 10.1016/0308-9126(88)90333-110.1016/0308-9126(88)90333-1 ↗
3. 10.1016/S0963-8695(00)00032-310.1016/S0963-8695(00)00032-3 ↗
4. 10.1016/j.ultras.2003.09.00410.1016/j.ultras.2003.09.004 ↗
5. 10.1109/IMTC.2002.100719310.1109/IMTC.2002.1007193 ↗
6. 10.1250/ast.30.42910.1250/ast.30.429 ↗
7. 10.1016/j.ndteint.2004.12.00310.1016/j.ndteint.2004.12.003 ↗
8. 10.1784/insi.2012.54.4.19310.1784/insi.2012.54.4.193 ↗
9. 10.1007/s10921-014-0263-710.1007/s10921-014-0263-7 ↗
10. 10.1007/s10921-015-0281-010.1007/s10921-015-0281-0 ↗
11. 10.1109/TUFFC.2013.285210.1109/TUFFC.2013.2852 ↗
12. Shen C · IEEE Trans Ultrason Ferroelectr Freq Control · 2012 · 59
13. 10.1016/j.ymssp.2012.10.01810.1016/j.ymssp.2012.10.018 ↗
14. 10.1109/TII.2015.250176210.1109/TII.2015.2501762 ↗
15. Mohamed I · Nondestr Test Eval · 2016
16. 10.1080/0934984960940959410.1080/09349849609409594 ↗
17. 10.1016/j.apacoust.2008.10.00510.1016/j.apacoust.2008.10.005 ↗
18. 10.1121/1.473089710.1121/1.4730897 ↗
19. 10.1109/ULTSYM.2014.003710.1109/ULTSYM.2014.0037 ↗
20. 10.1117/1.336030810.1117/1.3360308 ↗