journal article·2025-11-02

Image fusion of ultrasonic and thermography for delamination detection of CFRP based on data post-processing methods

Xiaoying Cheng, Tengkai Wang, Xiaolong Zhang, Kehong Zheng, Zhenyu Wu

Publisher page

Abstract

Delamination is crucial damage in carbon fibre reinforced polymer (CFRP) composites. Various non-destructive testing methods could detect the delamination with different merits. Ultrasonic can penetrate CFRP but has the dead zone effect, whereas thermography can reveal shallow defect but is insensitive to deep delamination. Therefore, in this work, the results of ultrasonic C-scan and locked-in thermography were fused to inspect the delamination. The ultrasonic C-scan images were processed by 6 dB drop criteria to quantify defect area. Principal component thermography, thermographic signal reconstruction and phase extraction were implemented on the thermographic images. C-scan images and thermographic images were fused using the proposed fusion algorithm that combines the evidence theory and minimum values. The performances of fused images were evaluated by the index of signal-to-noise ratio. The results show that the C-scan image fused with the thermographic phase image can significantly improve the signal-to-noise ratio of shallow defect detection and reduce the error with the actual defect area.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Thermography and Photoacoustic Techniques · Ultrasonics and Acoustic Wave Propagation · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Zhejiang Sci-Tech University

Zhejiang Provincial Innovation Center of Advanced Textile Technology

Key Laboratory of Modern Textile Machinery Technology of Zhejiang Province

Funding

National Natural Science Foundation of China · “Pioneer” and “Leading Goose” R&D Program of Zhejiang · Textile Vision Basic Research Program

References (45)

Show source-provided references
1. 10.1016/j.matpr.2018.10.06310.1016/j.matpr.2018.10.063 ↗
2. 10.2991/iwmecs-15.2015.1110.2991/iwmecs-15.2015.11 ↗
3. 10.1155/2020/881321310.1155/2020/8813213 ↗
4. 10.3390/s1605074310.3390/s16050743 ↗
5. 10.1155/2012/40843710.1155/2012/408437 ↗
6. 10.1016/j.ndteint.2018.11.01010.1016/j.ndteint.2018.11.010 ↗
7. Tigkos K, Hassler U, Holub W, et al. Regularization approach for tomosynthesis X-Ray inspection. 10th International Conference on Barkhausen and Micro-Magnetics (ICBM); Baltimore, MD. Amer Inst Physics; 2013. p. 1793–1799.
8. 10.1016/j.chemolab.2017.01.00810.1016/j.chemolab.2017.01.008 ↗
9. 10.1016/j.ndteint.2022.10265810.1016/j.ndteint.2022.102658 ↗
10. 10.1007/s10921-019-0569-610.1007/s10921-019-0569-6 ↗
11. Huo Y, Li HJ, Zhao YJ, et al. Study on the detectivity of the pulsed infrared thermograph. 5th international symposium on advanced optical manufacturing and testing technologies - optoelectronic materials and devices for detector, imager, display, and energy conversion technology. Dalian (PE)OPLES R CHINA: Spie-Int Soc Optical Engineering; 2010.
12. 10.3390/s2015411310.3390/s20154113 ↗
13. 10.1016/j.compstruct.2020.11240510.1016/j.compstruct.2020.112405 ↗
14. 10.1016/j.ndteint.2020.10224610.1016/j.ndteint.2020.102246 ↗
15. 10.1109/TIM.2020.299287310.1109/TIM.2020.2992873 ↗
16. 10.1080/10589759.2023.223454810.1080/10589759.2023.2234548 ↗
17. 10.1016/j.infrared.2020.10328910.1016/j.infrared.2020.103289 ↗
18. 10.3390/s2108259810.3390/s21082598 ↗
19. 10.1016/j.compstruct.2019.11179110.1016/j.compstruct.2019.111791 ↗
20. 10.3390/app1304273210.3390/app13042732 ↗
21. 10.1016/j.compositesa.2019.04.02210.1016/j.compositesa.2019.04.022 ↗
22. 10.1016/j.compscitech.2013.04.01310.1016/j.compscitech.2013.04.013 ↗
23. 10.3390/aerospace904018310.3390/aerospace9040183 ↗
24. 10.1109/TIM.2007.90813910.1109/TIM.2007.908139 ↗
25. 10.1002/stc.285710.1002/stc.2857 ↗
26. 10.1080/10589759.2023.227399910.1080/10589759.2023.2273999 ↗
27. 10.1080/10589759.2022.206328510.1080/10589759.2022.2063285 ↗
28. 10.1080/10589759.2024.232370310.1080/10589759.2024.2323703 ↗
29. 10.1080/10589759.2023.221428910.1080/10589759.2023.2214289 ↗
30. 10.1016/j.infrared.2018.08.02710.1016/j.infrared.2018.08.027 ↗
31. 10.1016/j.compscitech.2022.10952610.1016/j.compscitech.2022.109526 ↗
32. 10.1016/j.infrared.2019.01.02610.1016/j.infrared.2019.01.026 ↗
33. 10.1007/s10921-022-00883-010.1007/s10921-022-00883-0 ↗
34. 10.1016/j.ndteint.2017.04.00410.1016/j.ndteint.2017.04.004 ↗
35. 10.1016/j.ndteint.2020.10221510.1016/j.ndteint.2020.102215 ↗
36. 10.1016/j.polymertesting.2015.06.01610.1016/j.polymertesting.2015.06.016 ↗
37. 10.3390/app11241216810.3390/app112412168 ↗
38. 10.1007/s10921-021-00838-x10.1007/s10921-021-00838-x ↗
39. Li MJ, Wang XL, Dong YB. Research and development of multi-scale to pixel-level image fusion. International Conference on Renewable Energy and Environmental Technology (REET 2013); Jilin, Peoples R China. Trans Tech Publications Ltd; 2013. p. 3625–3628.
40. Singh R, Srivastava R, Prakash O, et al. Mixed scheme based multimodal medical image fusion using Daubechies complex wavelet transform. In: IEEE/OSA/IAPR International Conference on Informatics, Electronics and Vision (ICIEV); Dhaka, Bangladesh 2012. Univ Dhaka. p. 304–309.
41. 10.1016/j.measurement.2020.10844510.1016/j.measurement.2020.108445 ↗
42. 10.3390/ma1317384010.3390/ma13173840 ↗
43. 10.3390/s2002055910.3390/s20020559 ↗
44. 10.1109/TIM.2023.327799610.1109/TIM.2023.3277996 ↗
45. 10.1117/12.88740310.1117/12.887403 ↗