Pulsed eddy current array design and electromagnetic imaging for defects detection in metallic materials
Source abstract
Abstract
Defects caused by a harsh working environment and cyclic loading may seriously lead to catastrophic industrial accidents. Therefore, an efficient and accurate detection method is needed to quantitatively characterise the multiple defects of large-area metal components. In this paper, a pulsed eddy current (PEC) array is designed by considering mutual electromagnetic influence between the PEC array; the differential peak values at different scan positions are abstracted as feature signals for defect characterisation, and the relationship between defect width and detection signal is discovered; the detection capability of sensor array for adjacent defects is analysed. Subsequently, the electromagnetic imaging is applied to visualise and quantitatively evaluate the multiple defects, and then, the quantitative detection approaches for the localisation and width of multiple defects in metal components are proposed. An experimental setup is built and the proposed approach is validated by experiment. The results show that the proposed method can effectively determine the locations and widths of defects in metal components within the absolute error of 1 scan step.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Welding Techniques and Residual Stresses · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, P. R. China
School of Engineering, Newcastle University, Newcastle upon Tyne, UK
Funding
Nature Science Foundation of Guangdong Province · Fundamental Research Funds for the Central Universities · National Nature Science Foundation of China
References (32)
Show source-provided references
1. 10.1007/s11740-015-0644-510.1007/s11740-015-0644-5 ↗
2. 10.1007/s40534-017-0138-610.1007/s40534-017-0138-6 ↗
3. 10.1080/10589759.2010.52182710.1080/10589759.2010.521827 ↗
4. 10.1080/10589759.2016.124125010.1080/10589759.2016.1241250 ↗
5. 10.1016/j.ndteint.2009.10.01010.1016/j.ndteint.2009.10.010 ↗
6. 10.1016/j.ndteint.2020.10227310.1016/j.ndteint.2020.102273 ↗
7. 10.1016/j.ndteint.2013.07.00210.1016/j.ndteint.2013.07.002 ↗
8. 10.1080/1058975060078490210.1080/10589750600784902 ↗
9. 10.1016/j.ndteint.2007.03.00210.1016/j.ndteint.2007.03.002 ↗
10. 10.1016/j.ndteint.2014.06.00610.1016/j.ndteint.2014.06.006 ↗
11. 10.1080/10589759.2015.109362610.1080/10589759.2015.1093626 ↗
12. 10.1016/j.ndteint.2020.10226310.1016/j.ndteint.2020.102263 ↗
13. Ding TH · J Test Meas Technol · 2006 · 20 · 1
14. 10.1016/j.ndteint.2017.12.00110.1016/j.ndteint.2017.12.001 ↗
15. 10.1016/j.ndteint.2013.09.00410.1016/j.ndteint.2013.09.004 ↗
16. He YB · Transd Microsyst Technol · 2010 · 29 · 80
17. 10.3390/s1809290910.3390/s18092909 ↗
18. 10.1109/JSEN.2004.83912910.1109/JSEN.2004.839129 ↗
19. 10.1016/j.sna.2019.03.02910.1016/j.sna.2019.03.029 ↗
20. Lai S · Nondestr Test · 2011 · 33 · 13
21. Yang BF · J Transduction Technol · 2005 · 18 · 112
22. 10.1109/TIM.2021.311809210.1109/TIM.2021.3118092 ↗
23. Wang HT · Nondestr Test · 2010 · 32 · 560
24. Yu YT · Chin J Sci Instrum · 2007 · 28 · 1045
25. Liu SW · Transd Microsyst Technol · 2015 · 34 · 107
26. Jiao SB · Transd Microsyst Technol · 2013 · 32 · 30
27. 10.1016/j.measurement.2019.04.09110.1016/j.measurement.2019.04.091 ↗
28. 10.1016/j.jmmm.2020.16641210.1016/j.jmmm.2020.166412 ↗
29. Liu S · 2017
30. Yu YT · J BINDT-Insight · 2013 · 55 · 487
31. Yu YT · Sens Actuators A · 2019 · 111739
32. Peng YH · 2017 · 166