journal article·2020-07-02

Scanning trajectory optimisation using a quantitative Tuybased local quality estimation for robot-based X-ray computed tomography

Gabriel Herl, Jochen Hiller, Andreas Maier

Publisher page

Abstract

Robotic CT systems allow complex scanning trajectories. This work presents a workflow to automatically calculate optimised scanning trajectories for robotic CT systems. In particular, as a local quality estimation, this work introduces a quantitative measure to quantify local reconstruction quality based on the Tuy conditions. The proposed method is tested in two summation experiments using an STL model of a motorcycle. In both experiments, a trajectory is calculated using a quantitative Tuy-based local quality estimation and the reconstruction result is then compared to reconstructions using conventional scanning trajectories. The comparison results indicate that the proposed approach automatically finds trajectories that enable 3D reconstructions with high image quality using much less projection data, which allows a significant reduction of scanning time.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging · Medical Image Segmentation Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department Fraunhofer Application Center CTMT, Fraunhofer Institute for Integrated Circuits IIS, Deggendorf, Germany

Faculty Mechanical Engineering and Mechatronics, Deggendorf Institute of Technology, Deggendorf, Germany

Pattern Recognition Lab, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany

Funding

Bayerisches Staatsministerium für Wissenschaft und Kunst · Bayerisches Wirtschaftsministerium

References (20)

Show source-provided references
1. 10.1007/978-3-319-30050-4_5-110.1007/978-3-319-30050-4_5-1 ↗
2. 10.1118/1.59660710.1118/1.596607 ↗
3. Rehak M · 2nd Int Symp NDT Aerosp · 2010 · 22 · 24
4. 10.1137/014303510.1137/0143035 ↗
5. 10.1016/j.ndteint.2012.05.00210.1016/j.ndteint.2012.05.002 ↗
6. 10.1109/TVCG.2010.21410.1109/TVCG.2010.214 ↗
7. 10.1098/rspa.2017.031910.1098/rspa.2017.0319 ↗
8. 10.1117/12.224056610.1117/12.2240566 ↗
9. 10.1117/1.JMI.6.2.02500210.1117/1.JMI.6.2.025002 ↗
10. 10.1117/1.JMI.6.2.02500410.1117/1.JMI.6.2.025004 ↗
11. Zhao C · Med Imaging 2019 · 2019 · 10948 · 109481L
12. 10.1007/978-3-030-32254-0_210.1007/978-3-030-32254-0_2 ↗
13. 10.1007/978-3-662-46224-9_1010.1007/978-3-662-46224-9_10 ↗
14. 10.1118/1.370017210.1118/1.3700172 ↗
15. Kirillov AA · Doklady Akademii Nauk · 1961 · 137 · 276
16. 10.1088/0266-5611/11/2/00110.1088/0266-5611/11/2/001 ↗
17. Herl G · 2018
18. 10.1007/BF0302433110.1007/BF03024331 ↗
19. Kasperl S · 2014
20. Thingiverse. Mattos A; [cited 2019 Dec 11]. Availabe from: https://www.thingiverse.com/thing:1695883.