Micro-manufacturing for XCT spatial resolution verification objects
Source abstract
Abstract
X-ray Computed Tomography (XCT) is an often used non-destructive inspection tool. To identify small features and determine whether they are real or an image artefact, it is important to know the spatial resolution of the dataset. The typical rule-of-thumb for spatial resolution of a CT scan suggests a feature must be three voxels wide to be observed, but this is strongly dependent on scan quality. For a broad range of applications this estimate is sufficient but when working at the limits of the system capabilities numerical verification of the spatial resolution per scan would be preferred. Currently the most used verification method for spatial resolution is the JIMA chart but this is a 2D radiographic method that does not directly translate to the 3D reconstructed volume. This research identifies micro-manufacturing methods that can be used to make 3D spatial resolution verification objects, overcoming the limitations of macro manufacturing with small defined features but a large volume. Two different designs have been explored: intrusions and extrusions to represent both internal features such as pores and external features respectively. For simplicity, both are based on equidistant line pairs as per their 2D counterparts. For the intrusions PFIB was used to etch the features, while for the extrusions two photon polymerisation (2PP) and an electro chemical printing method were used. The research showed that while manufacturing volume and small features is still challenging, it is possible to make an object with walls in both a metal and a polymer with stable feature sizes down to 5 μ m . The 2PP method is particularly promising with aspect ratios down to 1:10, the relatively low cost and ease of access. The objects manufactured in this study can simply be replicated by other XCT users to verify the 3D spatial resolution in their scans, and can further be tailored for their sample.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · CCD and CMOS Imaging Sensors · Particle Detector Development and Performance
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. X-ray computed tomography10.1038/s43586-021-00015-4 ↗
2. Amplitude-wavelength maps for X-ray computed tomography systems10.1016/j.precisioneng.2020.03.005 ↗
3. Review of high-speed imaging with lab-based X-ray computed tomography10.1088/1361-6501/ac354a ↗
4. High-resolution X-ray computed tomography in geosciences: A review of the current technology and applications10.1016/j.earscirev.2013.04.003 ↗
5. Determining the spatial resolution in computed tomography-comparison of MTF and line-pair structures
6. BSI BS EN 16016-3:2011 · 2011
7. Über die abgrenzung von auflösungskonzepten in der industriellen computertomografie10.1515/teme-2022-0065 ↗
8. Determination of the image quality in computed tomography and its standardisation10.1007/s10921-025-01266-x ↗
9. ISO 19232-1:2004 · 2004
10. Reference object for evaluating the accuracy of porosity measurements by X-ray computed tomography10.1016/j.csndt.2016.05.003 ↗
11. Measurement of voids in composites by X-ray computed tomography10.1016/j.compscitech.2013.09.019 ↗
12. Tawfik A, Bills P, Blunt L, Racasan R. Development of an artefact to detect unfused powder in additive manufactured components using X-ray CT. In: 8th conference on industrial computed tomography. 2018.
13. A direct silicon bonded reference object for performance assessment of computed tomography systems10.1016/j.precisioneng.2019.04.017 ↗
14. Cost-effective micro-CT system for non-destructive testing of titanium 3D printed medical components10.1371/journal.pone.0275732 ↗
15. Bar and point test patterns generated by dry-etching for measurement of high spatial resolution in micro-CT
16. Aletheia. https://web.archive.org/web/20250501234911/https://aletheia-solutions.com/targets/. [Accessed May 2025].
17. Large volume serial section tomography by xe plasma FIB dual beam microscopy10.1016/j.ultramic.2015.11.001 ↗
18. White · 2020
19. Two-photon fabrication10.1038/nphoton.2009.131 ↗
20. Three-dimensional microfabrication with two-photon-absorbed photopolymerization10.1364/OL.22.000132 ↗
21. Obaton A-F, Klingaa CG, Rivet C, Mohaghegh K, Baier S, Andreasen JL, Carli L, De Chiffre L. Reference standards for XCT measurements of additively manufactured parts. In: 10th conference on industrial computed tomography. 2020.
22. Toward traceable XCT measurement of AM lattice structures: Uncertainty in calibrated reference object measurement10.1016/j.precisioneng.2022.05.010 ↗