journal article·2024-05Open access

Permanent fluidic magnets for liquid bioelectronics

Xun Zhao, Yihao Zhou, Yang Song, Jing Xu, Justin Li, Trinny Tat, Guorui Chen, Song Li, Jun Chen

Nature Materials· Volume 23· Issue 5

Abstract

Brownian motion allows microscopically dispersed nanoparticles to be stable in ferrofluids, as well as causes magnetization relaxation and prohibits permanent magnetism. Here we decoupled the particle Brownian motion from colloidal stability to achieve a permanent fluidic magnet with high magnetization, flowability and reconfigurability. The key to create such permanent fluidic magnets is to maintain a stable magnetic colloidal fluid by using non-Brownian magnetic particles to self-assemble a three-dimensional oriented and ramified magnetic network structure in the carrier fluid. This structure has high coercivity and permanent magnetization, with long-term magnetization stability. We establish a scaling theory model to decipher the permanent fluid magnet formation criteria and formulate a general assembly guideline. Further, we develop injectable and retrievable permanent-fluidic-magnet-based liquid bioelectronics for highly sensitive, self-powered wireless cardiovascular monitoring. Overall, our findings highlight the potential of permanent fluidic magnets as an ultrasoft material for liquid devices and systems, from bioelectronics to robotics.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Micro and Nano Robotics · Characterization and Applications of Magnetic Nanoparticles · Advanced Sensor and Energy Harvesting Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Yu, W. et al. A ferrobotic system for automated microfluidic logistics. Sci. Robot. 5, eaba4411 (2020).10.1126/scirobotics.aba4411 ↗
2. Zhang, J. et al. Wetting ridge assisted programmed magnetic actuation of droplets on ferrofluid-infused surface. Nat. Commun. 12, 7136 (2021).10.1038/s41467-021-27503-1 ↗
3. Liu, X. et al. Reconfigurable ferromagnetic liquid droplets. Science 365, 264–267 (2019).10.1126/science.aaw8719 ↗
4. Lee, J. H. et al. Exchange-coupled magnetic nanoparticles for efficient heat induction. Nat. Nanotechnol. 6, 418–422 (2011).10.1038/nnano.2011.95 ↗
5. Kim, C. et al. Gravitational stability of suspensions of attractive colloidal particles. Phys. Rev. Lett. 99, 028303 (2007).10.1103/PhysRevLett.99.028303 ↗
6. Buscall, R. The sedimentation of concentrated colloidal suspensions. Colloids Surf. 43, 33–53 (1990).10.1016/0166-6622(90)80002-L ↗
7. Manoharan Vinothan, N. Colloidal matter: packing, geometry, and entropy. Science 349, 1253751 (2015).10.1126/science.1253751 ↗
8. Perrin, J. Atoms. Authorised translation by D.L. Hammick (Constable, 1916).
9. Wang, C. et al. Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays. Nat. Biomed. Eng. 5, 749–758 (2021).10.1038/s41551-021-00763-4 ↗
10. Boutry, C. M. et al. Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow. Nat. Biomed. Eng. 3, 47–57 (2019).10.1038/s41551-018-0336-5 ↗
11. Kim, Y. et al. Chip-less wireless electronic skins by remote epitaxial freestanding compound semiconductors. Science 377, 859–864 (2022).10.1126/science.abn7325 ↗
12. Weitz, D. A. Soft materials evolution and revolution. Nat. Mater. 21, 986–988 (2022).10.1038/s41563-022-01356-5 ↗
13. Yan, Z. et al. Highly stretchable van der Waals thin films for adaptable and breathable electronic membranes. Science 375, 852–859 (2022).10.1126/science.abl8941 ↗
14. Wang, C. et al. Bioadhesive ultrasound for long-term continuous imaging of diverse organs. Science 377, 517–523 (2022).10.1126/science.abo2542 ↗
15. Kim, D. H. et al. Biofunctionalized magnetic-vortex microdiscs for targeted cancer-cell destruction. Nat. Mater. 9, 165–171 (2010).10.1038/nmat2591 ↗
16. Fan, X., Dong, X., Karacakol, A. C., Xie, H. & Sitti, M. Reconfigurable multifunctional ferrofluid droplet robots. Proc. Natl Acad. Sci. USA 117, 27916–27926 (2020).10.1073/pnas.2016388117 ↗
17. Mertelj, A., Lisjak, D., Drofenik, M. & Copic, M. Ferromagnetism in suspensions of magnetic platelets in liquid crystal. Nature 504, 237–241 (2013).10.1038/nature12863 ↗
18. Zhou, Y. et al. Giant magnetoelastic effect in soft systems for bioelectronics. Nat. Mater. 20, 1670–1676 (2021).10.1038/s41563-021-01093-1 ↗
19. Vecchio, D. A., Mahler, S. H., Hammig, M. D. & Kotov, N. A. Structural analysis of nanoscale network materials using graph theory. ACS Nano 15, 12847–12859 (2021).10.1021/acsnano.1c04711 ↗
20. Viveros, R. D. et al. Advanced one- and two-dimensional mesh designs for injectable electronics. Nano Lett. 19, 4180–4187 (2019).10.1021/acs.nanolett.9b01727 ↗
21. Hong, G. et al. Syringe injectable electronics: precise targeted delivery with quantitative input/output connectivity. Nano Lett. 15, 6979–6984 (2015).10.1021/acs.nanolett.5b02987 ↗
22. Liu, J. et al. Syringe-injectable electronics. Nat. Nanotechnol. 10, 629–636 (2015).10.1038/nnano.2015.115 ↗
23. Liu, Z. et al. Transcatheter self-powered ultrasensitive endocardial pressure sensor. Adv. Funct. Mater. 29, 1807560 (2019).10.1002/adfm.201807560 ↗
24. Hwang, J. C. et al. In situ diagnosis and simultaneous treatment of cardiac diseases using a single-device platform. Sci. Adv. 8, eabq0897 (2022).10.1126/sciadv.abq0897 ↗
25. About Multiple Cause of Death, 1999–2020 (National Center for Health Statistics, Centers for Disease Control and Prevention, 2022).
26. Fernández-Ruiz, I. Atrial fibrillation induces functional remodelling of the left ventricle. Nat. Rev. Cardiol. 19, 285 (2022).10.1038/s41569-022-00689-7 ↗
27. Witkowski, F. X. et al. Spatiotemporal evolution of ventricular fibrillation. Nature 392, 78–82 (1998).10.1038/32170 ↗
28. Schiavone, G. & Lacour Stéphanie, P. Conformable bioelectronic interfaces: mapping the road ahead. Sci. Transl. Med. 11, eaaw5858 (2019).10.1126/scitranslmed.aaw5858 ↗
29. Fernández-Ruiz, I. A robotic heart sleeve to keep the beat. Nat. Rev. Cardiol. 14, 129 (2017).10.1038/nrcardio.2017.14 ↗
30. Bannerman, D., Pascual-Gil, S. & Radisic, M. An optimal gel patch for the injured heart. Nat. Biomed. Eng. 3, 592–593 (2019).10.1038/s41551-019-0440-1 ↗
31. Implants that vanish. Nat. Biomed. Eng. 3, 585 (2019).10.1038/s41551-019-0449-5 ↗
32. Deng, J. et al. Electrical bioadhesive interface for bioelectronics. Nat. Mater. 20, 229–236 (2021).10.1038/s41563-020-00814-2 ↗
33. Dagdeviren, C. et al. Conformal piezoelectric systems for clinical and experimental characterization of soft tissue biomechanics. Nat. Mater. 14, 728–736 (2015).10.1038/nmat4289 ↗
34. Ryu, H. et al. Self-rechargeable cardiac pacemaker system with triboelectric nanogenerators. Nat. Commun. 12, 4374 (2021).10.1038/s41467-021-24417-w ↗
35. Choi, Y. S. et al. Fully implantable and bioresorbable cardiac pacemakers without leads or batteries. Nat. Biotechnol. 39, 1228–1238 (2021).10.1038/s41587-021-00948-x ↗
36. Wu, X. et al. Ferromagnetic liquid droplets with adjustable magnetic properties. Proc. Natl Acad. Sci. USA 118, e2017355118 (2021).10.1073/pnas.2017355118 ↗
37. Durable miniaturized bioelectronics. Nat. Biomed. Eng. 1, 0053 (2017).10.1038/s41551-017-0053 ↗