Mechanical characterizations of braided composite stents made of helical polyethylene terephthalate strips and NiTi wires
Source abstract
Abstract
Abstract The novel braided composite stent (BCS), woven with both nitinol wires and polyethylene terephthalate (PET) strips, were characterized and compared with the braided nitinol stent in the same weaving pattern. Finite element models simulating the stent compression and bending were developed to quantify its radial strength and longitudinal flexibility. The interaction between the nitinol wires and the PET strips were also delineated. Results showed that the PET strips enforced more constrains on the BCS and thus enhance its radial strength especially at a larger compression load. The longitudinal flexibility of the BCS was less sensitive to the presence of the PET strips. This work suggested that the novel design of the BCS could acquire the advantage of a covered stent without compromising its mechanical performance. The fundamental understanding of the braided composite stent will facilitate a better device design.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Shape Memory Alloy Transformations · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. The advantages of Aorfix for endovascular repair of abdominal aortic aneurysm
2. Comparison of the utility of covered metal stents versus uncovered metal stents in the management of malignant biliary strictures in 749 patients10.1016/j.gie.2013.02.032 ↗
3. Nanomedicine in diagnostics and therapy of cardiovascular diseases: beyond atherosclerotic plaque imaging10.1515/ntrev-2013-0009 ↗
4. Finite element analysis on the cyclic properties of superelastic Nitinol
5. Measurement of radial and axial forces of biliary self-expandable metallic stents10.1016/j.gie.2008.09.032 ↗
6. Predicting iliac limb occlusions after bifurcated aortic stent grafting: anatomic and device-related causes10.1016/S0741-5214(02)00117-9 ↗
7. The impact of wire stent fabrication technique on the performance of stent placement10.1115/1.4005788 ↗
8. Preliminary results of the initial United States experience with the Supera woven nitinol stent in the popliteal artery10.1016/j.jvs.2012.10.093 ↗
9. Endoscopic suture fixation of gastrointestinal stents: proof of biomechanical principles and early clinical experience10.1055/s-0032-1325730 ↗
10. Preliminary results of the initial United States experience with the Supera woven nitinol stent in the popliteal artery10.1016/j.jvs.2012.10.093 ↗
11. Virtual optimization of selfexpandable braided wire stents10.1016/j.medengphy.2008.11.008 ↗
12. Long and short of optimal stent design10.1136/openhrt-2017-000680 ↗
13. Mechanical characteristics of novel polyester/NiTi wires braided composite stent for the medical application10.1016/j.rinp.2016.07.007 ↗
14. Measurement of radial and axial forces of biliary self-expandable metallic stents10.1016/j.gie.2008.09.032 ↗
15. Endoscopic suture fixation of gastrointestinal stents: proof of biomechanical principles and early clinical experience10.1055/s-0032-1325730 ↗
16. Use of the Aorfix stent graft in patients with tortuous iliac anatomy
17. Biomedical application of commercial polymers and novel polyisobutylene-based thermoplastic elastomers for soft tissue replacement10.1021/bm034513k ↗
18. Use of the Aorfix stent graft in patients with tortuous iliac anatomy
19. Virtual optimization of selfexpandable braided wire stents10.1016/j.medengphy.2008.11.008 ↗
20. Nanomedicine in diagnostics and therapy of cardiovascular diseases: beyond atherosclerotic plaque imaging10.1515/ntrev-2013-0009 ↗
21. Coronary perforation and covered stents: an update and review, Heart views: Offic
22. Comparison of the utility of covered metal stents versus uncovered metal stents in the management of malignant biliary strictures in 749 patients10.1016/j.gie.2013.02.032 ↗
23. The advantages of Aorfix for endovascular repair of abdominal aortic aneurysm
24. Mechanical modeling of selfexpandable stent fabricated using braiding technology10.1016/j.jbiomech.2008.08.005 ↗
25. Predicting iliac limb occlusions after bifurcated aortic stent grafting: anatomic and device-related causes10.1016/S0741-5214(02)00117-9 ↗
26. Radial forces of stents used in thoracic endovascular aortic repair and bare self-expanding nitinol stents measured ex vivo–Rapid res cue for obstruction of the innominate artery using bare selfexpanding nitinol stents10.1177/1708538116640131 ↗
27. Radial compressive properties of the biodegradable braided regeneration tubes for peripheral nerve repair10.1177/1528083706064375 ↗
28. The impact of wire stent fabrication technique on the performance of stent placement10.1115/1.4005788 ↗
29. Radial compressive properties of the biodegradable braided regeneration tubes for peripheral nerve repair10.1177/1528083706064375 ↗
30. Comparative Study of the Effect of Structural Parameters on the Flexibility of Endovascular Stent Grafts
31. Radial forces of stents used in thoracic endovascular aortic repair and bare self-expanding nitinol stents measured ex vivo–Rapid res cue for obstruction of the innominate artery using bare selfexpanding nitinol stents10.1177/1708538116640131 ↗
32. Mechanical modeling of selfexpandable stent fabricated using braiding technology10.1016/j.jbiomech.2008.08.005 ↗
33. Finite element analysis on the cyclic properties of superelastic Nitinol
34. Mechanical characteristics of novel polyester/NiTi wires braided composite stent for the medical application10.1016/j.rinp.2016.07.007 ↗
35. Long and short of optimal stent design10.1136/openhrt-2017-000680 ↗
36. Coronary perforation and covered stents: an update and review, Heart views: Offic
37. Radial force measurements in carotid stents: influence of stent design and length of the lesion10.1016/j.jvir.2011.01.450 ↗
38. Radial force measurements in carotid stents: influence of stent design and length of the lesion10.1016/j.jvir.2011.01.450 ↗
39. Comparative Study of the Effect of Structural Parameters on the Flexibility of Endovascular Stent Grafts
40. Biomedical application of commercial polymers and novel polyisobutylene-based thermoplastic elastomers for soft tissue replacement10.1021/bm034513k ↗