Overcoming the quantification barrier in reverse tip sample scanning spreading resistance microscopy for efficient nanoscale carrier profiling
Source abstract
Abstract
Abstract The quick tip exchange capability of reverse tip sample (RTS) scanning probe microscopy (SPM) provides significant efficiency benefits over conventional SPM, especially in high-force modes like scanning spreading resistance microscopy (SSRM). While prior developments in RTS SSRM have addressed conductive diamond probe chip fabrication, sample preparation for electrical SPM measurements, and qualitative measurement capabilities, the challenge of achieving quantitative carrier profiling remained unresolved, primarily due to focused ion beam (FIB) damage that is introduced during RTS sample preparation. In this work, we present two different FIB-based RTS sample preparation protocols for mounting multiple samples on a single tipless cantilever. The core postulation is that co-mounting the target and calibration samples together ensures that they undergo identical ion beam exposure, thereby enabling accurate SSRM quantification. The first protocol employs sequential mounting of individual samples, while the second involves bonding the samples together, polishing their surfaces, and then, mounting them as a single, unified assembly. It is also worth noting that the latter protocol supports a sample layout that enables quantitative analysis to be done on each individual scanline, which can reduce the impact of measurement artefacts resulting from tip degradation or just unstable tip-sample contact during scanning. Quantitative validation of RTS SSRM for both preparation protocols was accomplished by implementing two different staircase calibration samples, comprised of layers having well-defined carrier concentrations. Finally, mounting a calibration sample alongside an actual device sample confirmed that RTS SSRM delivers results equivalent to those obtained with conventional SSRM, affirming its quantification reliability for practical applications. By establishing quantitative SSRM in RTS configuration, this work addresses a critical gap and further positions RTS SPM as a valuable approach for advancing electrical SPM characterization.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Force Microscopy Techniques and Applications · Near-Field Optical Microscopy · Surface and Thin Film Phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
IMEC
References (20)
Show source-provided references
1. One‐ and two‐dimensional carrier profiling in semiconductors by nanospreading resistance profiling10.1116/1.588478 ↗
2. The enduring legacy of scanning spreading resistance microscopy: overview, advancements, and future directions10.1063/5.0280969 ↗
3. Scanning spreading resistance microscopy (SSRM) 2d carrier profiling for ultra-shallow junction characterization in deep-submicron technologies10.1016/j.mseb.2005.08.049 ↗
4. Quantitative two-dimensional carrier mapping in silicon nanowire-based tunnel-field effect transistors using scanning spreading resistance microscopy10.1557/PROC-1258-P06-02 ↗
5. Quantitative three-dimensional carrier mapping in nanowire-based transistors using scanning spreading resistance microscopy10.1016/j.ultramic.2012.10.008 ↗
6. Two-dimensional profiling of carriers in a buried heterostructure multi-quantum-well laser: calibrated scanning spreading resistance microscopy and scanning capacitance microscopy10.1116/1.1511211 ↗
7. High-resolution and site-specific SSRM on S/D engineering10.1109/IWJT.2010.5474914 ↗
8. Towards routine, quantitative two-dimensional carrier profiling with scanning spreading resistance microscopy10.1063/1.1354465 ↗
9. Crystal data for high-pressure phases of silicon10.1103/PhysRevB.34.4679 ↗
10. Recent insights into the physical modeling of the spreading resistance point contact10.1116/1.588475 ↗
11. Pulsed force-scanning spreading resistance microscopy (PF-SSRM) for high spatial resolution 2D-dopant profiling10.1557/PROC-717-C7.7 ↗
12. Probe chip nanofabrication enabled reverse tip sample scanning probe microscopy concept and measurements10.1088/1361-6528/ad3744 ↗
13. Nanofabrication of sharp conductive diamond tip probe chips and their application in reverse tip sample scanning probe microscopy10.1016/j.mne.2025.100307 ↗
14. Enabling focused ion beam sample preparation for application in reverse tip sample scanning probe microscopy10.1016/j.mne.2024.100247 ↗
15. Leveraging artificial intelligence and reverse tip sample configuration for automation of data processing in quantitative scanning spreading resistance microscopy10.1002/pssa.202400688 ↗
16. Experimental observation of FIB induced lateral damage on silicon samples10.1016/j.mee.2009.01.003 ↗
17. Comprehensive study of focused ion beam induced lateral damage in silicon by scanning probe microscopy techniques10.1116/1.3431085 ↗
18. The impact of focused ion beam induced damage on scanning spreading resistance microscopy measurements10.1038/s41598-020-71826-w ↗
19. On the effects of a pressure induced amorphous silicon layer on consecutive spreading resistance microscopy scans of doped silicon10.1063/1.4923052 ↗
20. Improved 2D charge carrier quantification workflow for scanning spreading resistance microscopy10.1016/j.microrel.2025.115646 ↗