journal article·2024-08-23

Cobalt-Doped ZIF-8 Nanoparticle-Decorated Fiber Optic Sensor for Copper Ion Detection

Swetha Menon, Sourav Dutta, Narayanan Madaboosi, V. V. R. Sai

ACS Applied Nano Materials· Volume 7· Issue 16
Publisher page

Abstract

Copper is a toxic water contaminant; its quantification below the maximum contaminant level (MCL) of 1.3 ppm by a sensitive, field-deployable sensor becomes critical. Here, the cobalt-doped zeolitic-imidazolate framework (Co/ZIF-8) nanomaterial was developed as a novel, highly selective, sensitive, and stable chemoreceptor as an alternative to ZIF-8 for Cu(II) ion detection. A dip-type optical absorption Cu(II) ion sensor was realized by an in situ deposition of Co/ZIF-8 nanoparticles over a highly sensitive U-bent fiber optic sensor (FOS) probe with a remarkable high evanescent wave-based absorption (EWA) sensitivity. The Co/ZIF-8 coated FOS works on the principle of attenuation of the light passing through the FOS by the Co/ZIF-8 nanoparticles due to EWA at 400 nm wavelength upon interaction with Cu(II) ions and increases proportional to the Cu(II) ions concentrations. The interaction of Cu(II) ions with Co/ZIF-8 nanoparticles was extensively characterized with the help of UV–visible absorption, scanning electron microscopy and EDAX analysis, X-ray diffraction, and FTIR absorption spectral analysis. Cu(II) ions were found to replace Zn(II) in the Co/ZIF-8, forming Cu-imidazole complexes over and off the nanoparticles, leaving the surface rich with Co- and Cu-imidazole complexes and thereby altering the optical and morphological properties of the Co/ZIF-8. The sensor demonstrated an excellent dynamic range of 0.05–100 ppm with an experimental LoD of 50 ppb using a simple LED-photodetector-based setup, selectivity for Cu(II) against 12 other potential interfering metal ions, and a shelf life of at least 3 months. The facile and scalable Co/ZIF-8 deposition process, simpler instrumentation, excellent sensor parameters, and good recovery rates with field water samples make this strategy highly promising for on-site environmental monitoring.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Molecular Sensors and Ion Detection · Advanced Nanomaterials in Catalysis · Advanced biosensing and bioanalysis techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (57)

Show source-provided references
1. 10.1016/j.snb.2023.13348710.1016/j.snb.2023.133487 ↗
2. 10.1007/978-981-10-8022-7_10310.1007/978-981-10-8022-7_103 ↗
3. 10.1007/s00204-014-1355-y10.1007/s00204-014-1355-y ↗
4. WHO (World Health Organization). Copper in Drinking-Water Background Document for Development of WHO Guidelines for Drinking-Water Quality; World Health Organization, 1997; Vol. 68.10.1111/1467-8292.00035 (accessed November 8, 2023).10.1111/1467-8292.00035 ↗
5. United States Environmental Protection Agency. National Primary Drinking Water Guidelines; United States Environmental Protection Agency, 2009; Vol. 1. https://www.epa.gov/sites/default/files/2016-06/documents/npwdr_complete_table.pdf (accessed November 8, 2023).
6. Bureau of Indian Standards. Tolerance and Classification; Bureau of Indian Standards: New Delhi, 1982. http://cgwb.gov.in/Documents/WQ-standards.pdf (accessed November 8, 2023).
7. Geneva: World Health Organization · 2021
8. NT Sensors. Modular ION_Mini 2.5 NT Sensors. https://www.ntsensors.com/parameters/copper-ion-selective-electrode (accessed November 8, 2023).
9. ECD Analyzers. Model CA-6 Copper Analyzer - Compact Online Colorimeter for the Automatic Measurement of Copper in Water; ECD Analyzers, 2015. https://ecdi.com/wp-content/uploads/2015/05/CA6-Copper-Analyzer.pdf (accessed November 8, 2023).
10. Libelium. Libelium Waspmote Smart Water; Libelium, 2020. https://www.libelium.com/wp-content/uploads/2020/06/Water-Quality-Sensors-Overview_Libelium.pdf (accessed November 8, 2023).
11. 10.3390/s2104110910.3390/s21041109 ↗
12. 10.1016/j.snb.2017.11.01310.1016/j.snb.2017.11.013 ↗
13. 10.1016/j.aca.2015.09.00210.1016/j.aca.2015.09.002 ↗
14. 10.1557/jmr.2014.14510.1557/jmr.2014.145 ↗
15. 10.1021/acs.cgd.8b0022410.1021/acs.cgd.8b00224 ↗
16. 10.1016/j.bios.2016.05.00710.1016/j.bios.2016.05.007 ↗
17. 10.1016/j.saa.2014.08.13510.1016/j.saa.2014.08.135 ↗
18. 10.1016/j.matchemphys.2018.06.00310.1016/j.matchemphys.2018.06.003 ↗
19. 10.1039/C5AY02047F10.1039/C5AY02047F ↗
20. 10.5772/intechopen.8629010.5772/intechopen.86290 ↗
21. 10.3390/molecules2424460510.3390/molecules24244605 ↗
22. 10.1016/j.jhazmat.2019.12166710.1016/j.jhazmat.2019.121667 ↗
23. 10.1080/10408347.2022.210654310.1080/10408347.2022.2106543 ↗
24. 10.1021/acssensors.2c0217010.1021/acssensors.2c02170 ↗
25. 10.1021/acsami.1c2319910.1021/acsami.1c23199 ↗
26. 10.1007/s00216-019-02353-510.1007/s00216-019-02353-5 ↗
27. 10.1039/C9RA10695B10.1039/C9RA10695B ↗
28. 10.1016/j.cej.2022.13632010.1016/j.cej.2022.136320 ↗
29. 10.1039/D2EN00601D10.1039/D2EN00601D ↗
30. 10.1016/j.cej.2019.03.23610.1016/j.cej.2019.03.236 ↗
31. 10.1002/adma.20220822410.1002/adma.202208224 ↗
32. 10.1039/C3TA15058E10.1039/C3TA15058E ↗
33. 10.3390/s1923524610.3390/s19235246 ↗
34. 10.1016/j.bios.2018.03.04010.1016/j.bios.2018.03.040 ↗
35. 10.3390/mi909047110.3390/mi9090471 ↗
36. 10.1016/j.snb.2020.12848010.1016/j.snb.2020.128480 ↗
37. 10.1016/j.snb.2020.12846310.1016/j.snb.2020.128463 ↗
38. 10.1016/j.bios.2009.02.00710.1016/j.bios.2009.02.007 ↗
39. 10.1109/JLT.2019.295804410.1109/JLT.2019.2958044 ↗
40. 10.1007/BF0033105310.1007/BF00331053 ↗
41. Sai, R. V.; Swamy, L. V. Apparatus to Fabricate Fiber Optic Sensor Probes and Method of Fabrication Thereof. Patent no: WO2021/095060A1, 2021.
42. 10.1021/acs.cgd.6b0109010.1021/acs.cgd.6b01090 ↗
43. 10.1016/j.cej.2012.08.06510.1016/j.cej.2012.08.065 ↗
44. 10.1039/c3dt50351h10.1039/c3dt50351h ↗
45. 10.1039/C6DT01827K10.1039/C6DT01827K ↗
46. 10.1021/acsami.7b0051210.1021/acsami.7b00512 ↗
47. 10.3390/nano1009163610.3390/nano10091636 ↗
48. 10.1038/s41598-018-28015-710.1038/s41598-018-28015-7 ↗
49. 10.1016/j.chempr.2019.03.02510.1016/j.chempr.2019.03.025 ↗
50. 10.1016/j.dyepig.2019.10770710.1016/j.dyepig.2019.107707 ↗
51. 10.1021/ac501515f10.1021/ac501515f ↗
52. 10.1039/C9RA10174H10.1039/C9RA10174H ↗
53. 10.1007/978-3-319-20790-210.1007/978-3-319-20790-2 ↗
54. 10.9734/BJMMR/2014/687510.9734/BJMMR/2014/6875 ↗
55. 10.1088/1361-6528/aab4c410.1088/1361-6528/aab4c4 ↗
56. 10.1039/b920783j10.1039/b920783j ↗
57. 10.1155/2019/738104610.1155/2019/7381046 ↗