journal article·2014-12-10

Frequency-Encoded MRI-CEST Agents Based on Paramagnetic Liposomes/RBC Aggregates

Giuseppe Ferrauto, Enza Di Gregorio, Simona Baroni, Silvio Aime

Nano Letters· Volume 14· Issue 12
Publisher page

Abstract

Paramagnetic liposomes containing Dy-HPDO3A in their inner water compartment and carrying a residual positive charge on their outer surface have been electrostatically bound to the membrane of red blood cells (RBCs). These aggregates yield two chemical exchange saturation transfer (CEST) pools represented by liposomal water protons (LipoCEST) and cytoplasmatic water protons (ErythroCEST), respectively. The absorption frequencies of the two pools fall at the negative and positive side of the solvent water resonance as expected from the dipolar (LipoCEST) and BMS (bulk magnetic susceptibility) (ErythroCEST) origin of the paramagnetic induced shift of their water protons resonances, respectively. In vivo magnetic resonance imaging (MRI) shows that the liposomes/RBC aggregates report about the vascular volume whereas the residual LipoCEST effect informs about the presence of released liposomes in the region of interest (ROI). Besides being an innovative blood cell labeling for MRI, the LipoCEST/RBC aggregates provide a route to improve the circulation lifetime of the liposomes and the CEST procedure allows assessing the deassembly of the aggregates and accumulation of the liposomes in the ROI.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Lanthanide and Transition Metal Complexes · Advanced MRI Techniques and Applications · Electron Spin Resonance Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Molecular Imaging Center, Department of Molecular Biotechnologies & Health Sciences, University of Torino, Torino, Italy

Institute for Advanced Study, Technische Universitat Munchen, Munich, Germany

Funding

European Cooperation in Science and Technology · Consorzio Interuniversitario di Ricerca in Chimica dei Metalli nei Sistemi Biologici

References (23)

Show source-provided references
1. Ward K. M. · J. Magn. Reson. · 2000 · 143 · 7910.1006/jmre.1999.1956 ↗
2. Sherry A. D. · Annu. Rev. Biomed. Eng. · 2008 · 10 · 39110.1146/annurev.bioeng.9.060906.151929 ↗
3. Langereis S. · J. Am. Chem. Soc. · 2009 · 131 · 138010.1021/ja8087532 ↗
4. Burdinski D. · Angew. Chem., Int. Ed. · 2010 · 49 · 222710.1002/anie.200905731 ↗
5. Terreno E. · Contrast Media Mol. Imaging · 2010 · 5 · 7810.1002/cmmi.369 ↗
6. Zhang S. · Acc. Chem. Res. · 2003 · 36 · 78310.1021/ar020228m ↗
7. van Zijl P. C. · Magn. Reson. Med. · 2011 · 65 · 92710.1002/mrm.22761 ↗
8. Ferrauto G. · Magn. Reson. Med. · 2013 · 69 · 170310.1002/mrm.24411 ↗
9. Aime S. · Angew.Chem., Int. Ed. · 2005 · 44 · 181310.1002/anie.200462566 ↗
10. McMahon M. T. · Magn. Reson. Med. · 2008 · 60 · 80310.1002/mrm.21683 ↗
11. De Leon-Rodriguez L. M. · Acc. Chem. Res. · 2009 · 42 · 94810.1021/ar800237f ↗
12. Delli Castelli D. · Magn. Reson. Med. · 2014 · 71 · 32610.1002/mrm.24664 ↗
13. 10.1002/mrm.2476310.1002/mrm.24763 ↗
14. 10.1002/mrm.2505310.1002/mrm.25053 ↗
15. Terreno E. · Chemistry · 2009 · 15 · 144010.1002/chem.200801766 ↗
16. Aime S. · Methods Enzymol. · 2009 · 464 · 19310.1016/S0076-6879(09)64010-6 ↗
17. Terreno E. · Angew. Chem., Int. Ed. · 2007 · 46 · 96610.1002/anie.200604027 ↗
18. Peters J. A. · Prog. Nucl. Magn. Reson. Spectrosc. · 1996 · 28 · 28310.1016/0079-6565(95)01026-2 ↗
19. Ferrauto G. · J. Am. Chem. Soc. · 2014 · 136 · 63810.1021/ja411793u ↗
20. Di Gregorio E. · Contrast Media Mol. Imaging · 2013 · 8 · 47510.1002/cmmi.1574 ↗
21. Di Gregorio E. · Anal. Chem. · 2013 · 85 · 562710.1021/ac400973q ↗
22. Caravan P. · Chem. Rev. · 1999 · 99 · 229310.1021/cr980440x ↗
23. Vinogradov E. · J. Magn. Reson. · 2013 · 229 · 15510.1016/j.jmr.2012.11.024 ↗