Direct Observation of Acoustic Oscillations in InAs Nanowires
Source abstract
Abstract
Time-resolved X-ray diffraction and optical reflectivity are used to directly measure three different acoustic oscillations of InAs nanowires. The oscillations are excited by a femtosecond laser pulse and evolve at three different time scales. We measure the absolute scale of the initial radial expansion of the fundamental breathing eigenmode and determine the frequency by transient optical reflectivity. For the extensional eigenmode we measure the oscillations of the average radial and axial lattice constants and determine the amplitude of oscillations and the average extension. Finally we observe a bending motion of the nanowires. The frequencies of the eigenmodes are in good agreements with predictions made by continuum elasticity theory and we find no difference in the speed of sound between the wurtzite nanowires and cubic bulk crystals, but the measured strain is influenced by the interaction between different modes. The wurtzite crystal structure of the nanowires however has an anisotropic thermal expansion.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Mechanical and Optical Resonators · Nanowire Synthesis and Applications · Thermal properties of materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Centre for Molecular Movies
European Synchrotron Radiation Facility, Grenoble Cedex 38043, France
Nano-Science Center
References (31)
Show source-provided references
1. Ekinci K. L. · Rev. Sci. Instrum. · 2005 · 76 · 06110110.1063/1.1927327 ↗
2. Yan R. · Nat. Photonics · 2009 · 3 · 56910.1038/nphoton.2009.184 ↗
3. Hochbaum A. I. · Chem. Rev. · 2010 · 110 · 52710.1021/cr900075v ↗
4. Xia Y. · Adv. Mater. · 2003 · 15 · 35310.1002/adma.200390087 ↗
5. Lange H. · Nano Lett. · 2008 · 8 · 461410.1021/nl803134t ↗
6. Hu M. · J. Am. Chem. Soc. · 2003 · 125 · 1492510.1021/ja037443y ↗
7. Nam C.-Y. · Nano Lett. · 2006 · 6 · 15310.1021/nl051860m ↗
8. Smith D. A. · J. Phys. Chem. C · 2008 · 112 · 1072510.1021/jp8010487 ↗
9. Wong E. W. · Science · 1997 · 277 · 197110.1126/science.277.5334.1971 ↗
10. Chen C. Q. · Phys. Rev. Lett. · 2006 · 96 · 07550510.1103/PhysRevLett.96.075505 ↗
11. Flannigan D. J. · Nano Lett. · 2009 · 9 · 87510.1021/nl803770e ↗
12. Zijlstra P. · Nano Lett. · 2008 · 8 · 349310.1021/nl802480q ↗
13. Owrutsky J. C. · J. Phys. Chem. C · 2009 · 113 · 1094710.1021/jp902398p ↗
14. Kolomenskii A. A. · J. Appl. Phys. · 2008 · 104 · 103110.1610.1063/1.3021101 ↗
15. Chen C. Q. · Phys. Rev. Lett. · 2006 · 96 · 07550510.1103/PhysRevLett.96.075505 ↗
16. Yu P. · J.Phys.Chem.C · 2008 · 112 · 1713310.1021/jp806498y ↗
17. Nichol J. M. · Appl. Phys. Lett. · 2008 · 93 · 19311010.1063/1.3025305 ↗
18. Belov M. · J. Appl. Phys. · 2008 · 103 · 07430410.1063/1.2891002 ↗
19. Nilsson S. G. · Appl. Phys. Lett. · 2004 · 85 · 355510.1063/1.1807945 ↗
20. Bargheer M. · Science · 2004 · 306 · 177110.1126/science.1104739 ↗
21. Landau, L. D.; Pitaevskii, L. P.; Lifshitz, E. M.; Kosevich, A. M.Theory of Elasticity,3rded.Butterworth-Heinemann:Oxford and New York, 1986.
22. There appears to be an error in formula 3 in ref6, where sin and cos have been interchanged.
23. Mariager S. O. · J. Appl. Crystallogr. · 2009 · 42 · 36910.1107/S0021889809009145 ↗
24. Cammarata M. · Rev. Sci. Instrum. · 2009 · 80 · 01510110.1063/1.3036983 ↗
25. Thomsen C. · Phys. Rev. B · 1986 · 34 · 412910.1103/PhysRevB.34.4129 ↗
26. Bucksbaum P. H. · Science · 2004 · 306 · 169310.1126/science.1106755 ↗
27. Burenkov Y. A. · Sov. Phys. Solid State · 1975 · 17 · 1446
28. Zhang J.-M. · J. Phys. Chem. Solids · 2007 · 68 · 50310.1016/j.jpcs.2007.01.025 ↗
29. Zubrilov, A.InProperties of Advanced SemiconductorMaterials GaN, AlN, InN, BN, SiC, SiGe;Levinshtein, M. E.; Rumyantsev, S. L.; Shur, M. S., Eds.John Wiley & Sons:New York, 2001; pp49−66.
30. Hartland G. V. · J. Chem. Phys. · 2002 · 116 · 804810.1063/1.1469021 ↗
31. We did not determine the damage threshold, but a laser power of 199 mW reduced the X-ray signal by 50% in 1 s and visibly damaged the sample.