Polycyanurate Nanorod Arrays for Optical-Waveguide-Based Biosensing
Source abstract
Abstract
We demonstrate high-sensitivity biosensing by optical waveguide spectroscopy (OWS) at visible wavelengths using aligned polycyanurate thermoset nanorods (PCNs) arranged in extended arrays as waveguides. The PCNs formed by thermal polymerization of a cyanate ester monomer in self-ordered nanoporous alumina templates were 60 nm in diameter and 650 nm in length. Subtle refractive index changes of the medium surrounding the nanorods could be detected by monitoring the angular shifts of waveguiding modes. The sensing figure of merit thus achieved amounted to 196 reciprocal refractive index units and is, therefore, higher than that of other sensors based on angular modulation, while the configuration used here is eligible for further surface functionalization. Kinetics of the binding of taurine to the surface cyanate groups of the PCNs was monitored by OWS. Thus, modified PCNs bearing sulfonic acid groups at their surfaces were obtained. PCN arrays may represent a versatile platform for the design of biosensors.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Anodic Oxide Films and Nanostructures · Analytical Chemistry and Sensors · Acoustic Wave Resonator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Austrian Institute of Technology GmbH—AIT, Nano Systems, Donau-City-Strasse 1, 1220 Vienna, Austria
Max-Planck Institut für Polymerforschung, 55128 Mainz, Germany
Universtät Osnabrück, Institut für Chemie, 49069 Osnabrück, Germany
References (32)
Show source-provided references
1. Martin C. R. · Science · 1994 · 266 · 196110.1126/science.266.5193.1961 ↗
2. Steinhart M. · Adv. Polym. Sci. · 2008 · 220 · 123
3. Masuda H. · Science · 1995 · 268 · 146610.1126/science.268.5216.1466 ↗
4. Masuda H. · J. Electrochem. Soc. · 1997 · 144 · L12710.1149/1.1837634 ↗
5. Nielsch K. · Nano Lett. · 2002 · 2 · 67710.1021/nl025537k ↗
6. Lau K. H. A. · J. Phys. Chem. B · 2004 · 108 · 1081210.1021/jp0498567 ↗
7. Awazu K. · Opt. Express · 2007 · 15 · 259210.1364/OE.15.002592 ↗
8. Fujimaki M. · Microelectron. Eng. · 2007 · 84 · 168510.1016/j.mee.2007.01.264 ↗
9. Cameron P. J. · J. Mater. Chem. · 2008 · 18 · 430410.1039/b805733h ↗
10. Lau K. H. A. · J. Phys. Chem. B · 2009 · 113 · 317910.1021/jp809593d ↗
11. Kabashin A. V. · Nat. Mater. · 2009 · 8 · 86710.1038/nmat2546 ↗
12. Grimm S. · Nano Lett. · 2008 · 8 · 195410.1021/nl080842c ↗
13. Aust E. · Trends Polym. Sci. · 1994 · 2 · 313
14. Knoll W. · Annu. Rev. Phys. Chem. · 1998 · 49 · 56910.1146/annurev.physchem.49.1.569 ↗
15. Yameen B. · Macromol. Chem. Phys. · 2008 · 209 · 167310.1002/macp.200800155 ↗
16. Choy T. C. · 1999
17. Aspnes D. E. · Thin Solid Films · 1982 · 89 · 24910.1016/0040-6090(82)90590-9 ↗
18. Giordano S. · J. Electrostat. · 2003 · 58 · 5910.1016/S0304-3886(02)00199-7 ↗
19. Skryabin I. L. · Appl. Phys. Lett. · 1997 · 222110.1063/1.118821 ↗
20. Hornyak G. J. · Nanostruct. Mater. · 1997 · 9 · 57110.1016/S0965-9773(97)00127-X ↗
21. Yimit A. · Talanta · 2005 · 65 · 110210.1016/j.talanta.2004.06.045 ↗
22. Homola J. · Sens. Actuators, B · 1999 · 54 · 1610.1016/S0925-4005(98)00322-0 ↗
23. Dostalek J. · Plasmonics · 2007 · 2 · 9710.1007/s11468-007-9037-8 ↗
24. Axen R. · Nature · 1967 · 214 · 130210.1038/2141302a0 ↗
25. Wang T. · Int. J. Pharm. · 2005 · 306 · 13210.1016/j.ijpharm.2005.09.011 ↗
26. Mattern K. J. · Carbohyd. Res. · 2007 · 342 · 219210.1016/j.carres.2007.06.007 ↗
27. Schuller-Levis G. B. · FEMS Microbiol. Lett. · 2003 · 226 · 19510.1016/S0378-1097(03)00611-6 ↗
28. Kim D.-H. · Small · 2005 · 1 · 9910.1002/smll.200400024 ↗
29. Feng C. L. · Small · 2008 · 4 · 56610.1002/smll.200700453 ↗
30. Decher G. · Macromol. Chem. Macromol. Symp. · 1991 · 46 · 32110.1002/masy.19910460145 ↗
31. Beukes J. A. · Phys. Chem. Chem. Phys. · 2007 · 9 · 470910.1039/b703000b ↗
32. XPS measurements were carried out on a Physical Electronics 5600 A instrument using a Mg Kα (1253.6 eV) X-ray source operated at 300 W. The XPS scans were analyzed using the software MultiPack 5.0.