journal article·2019-08Open access

Improvement of Spatial Resolution in Z Direction with Improved Energy Spread Measured using Aberration Corrected STEM with Cold Field Emission Gun

Hiroki Hashiguchi, Ryusuke Sagawa, Noriaki Endo, Eiji Okunishi, Yukihito Kondo

Microscopy and Microanalysis· Volume 25· Issue S2

Abstract

Recently, the spatial resolution of scanning transmission microscope (STEM) has dramatically improved owing to an aberration corrector. The primary benefit of the aberration corrector is a wide flat area of the Ronchigram and a large convergence angle for a STEM probe. In the STEM, the spatial resolution improves as the convergence angle increases, because diffraction limit (d) decreases (d = 0.6/, : wavelength, : convergence angle). In a recent aberration corrector, the allowable convergence angle has become 70 mrad or more, since the fifth order aberration can be corrected As a result, with the corrector, atomic resolution has become realized in both image observation and analysis by EDS and/or EELS. However, the acquired STEM image is basically two-dimensional map. Although it is convenient if it is an ideal sample like mono-atomic layered sample, the practical sample, which we observe and analyze, actually contains many defects and impurities, which distribute three dimensionally. Thus, it is important to characterize the sample three dimensionally. Therefore, the three dimensional spatial resolution is necessary for the observation and analysis. Modern aberration corrector improves depth resolution (dz) further, since larger convergence angle is obtainable due to corrections of higher order geometrical aberrations. This leads that optical slicing of the sample observation may be doable similar to confocal optical microscopy with modern aberration correctors. In this paper, we report dz obtained through various practical experimental tests. The depth resolution [2] is represented by the relation: dz = / 2 -(1). First, we examined this equation. To estimate dz, through-focal series of the STEM images were acquired using a sample of mono-layer graphene. For this experiment, we used a 200-kV aberration corrected microscope (JEOL: NEOARM), equipped with cold field emission gun and electron energy spectrometer (EELS). The acceleration voltage for this experiment was 80 kV and number of images in a series was 40. Then, we calculated the standard deviation (image) of the intensities at the pixels over a STEM image. The image of an image with sharp peaks is larger than that of an image with dull peaks, under the same experimental condition such as probe current and detector. Thus, we evaluate the sharpness of atomic peak in an image with the image. We carried out this calculation for all images of the through focus series. Figure The convergence angle was 37 mrad and the focus was shifted by 0.7 nm step in a through-focus series. The red rhomboids plot the values obtained by experiment, and the black solid line is fitted with a Gaussian function. The full width of half maximum (FWHM) fitted with the Gaussian function was evaluated as the depth resolution. Figure The black solid line plots the calculated values by the equation (1), and red rhomboids plot the values obtained by experiment. As the convergence angle increases, the depth resolution improves. And in the larger convergence angle, the difference between the calculated and experimental values becomes large. We presume that this is mainly due to chromatic aberration, that is, focus variation on different energy of electrons. Thus, we next measured through-focus series on different energy spreads, which were measured with EELS.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Electron Microscopy Techniques and Applications · Integrated Circuits and Semiconductor Failure Analysis · Advanced X-ray Imaging Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (2)

Show source-provided references
1. 10.1016/j.ultramic.2006.04.02010.1016/j.ultramic.2006.04.020 ↗
2. 10.1093/jmicro/dfy00910.1093/jmicro/dfy009 ↗