Low-Voltage Electron-Probe Microanalysis of Uranium
Source abstract
Abstract
Electron-probe microanalysis of uranium and uranium alloys poses several problems, such as rapid oxidation, large poorly constrained correction factors, and a large number of characteristic x-ray lines. We show that U-metal can grow 10 nm of oxide within ~20 s of air exposure, increasing to 15–20 nm within a few minutes, which can produce a 30% quantification error at 5 kV. A 15 nm carbon coating on the UO2 reference material also produces an ~30% quantification error of the uncoated but surface oxidized U sample at 5 kV. Correcting for both the coating and oxide improved the analysis accuracy to better than ±1% down to 7 kV and ~2% at 5 kV, but the error increases strongly below this. The measurement of C in U identified a previously unreported U N6–O4 line interference on the C Kα peak, which can produce over 1% error in the analysis total. Oxide stoichiometry was demonstrated to have only a small impact on quantification. The measurement of the O Kα and U Mα mass absorption coefficients in U as 9,528 and 798 cm2/g, respectively, shows good agreement with recently published values and also produces small differences in a quantification error.
Source: openalex_inverted_index · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Advanced Materials Characterization Techniques · Radioactive element chemistry and processing
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. 10.1016/S0022-3115(98)00012-910.1016/S0022-3115(98)00012-9 ↗
2. Reed · 1975
3. 10.1006/adnd.1993.101310.1006/adnd.1993.1013 ↗
4. 10.1002/sca.2000010.1002/sca.20000 ↗
5. 10.1246/bcsj.55.230510.1246/bcsj.55.2305 ↗
6. 10.1088/0022-3727/8/7/02010.1088/0022-3727/8/7/020 ↗
7. 10.1007/978-3-7091-6679-6_210.1007/978-3-7091-6679-6_2 ↗
8. 10.1088/0508-3443/15/3/30510.1088/0508-3443/15/3/305 ↗
9. Hakkila, EA , Waterbury, GR & Metz, CF (1964). Electron microprobe examination of delta-stabilized plutonium. Los Alamos Report LA-3125.
10. 10.1007/978-1-4899-2617-3_910.1007/978-1-4899-2617-3_9 ↗
11. 10.1088/1757-899X/55/1/01200910.1088/1757-899X/55/1/012009 ↗
12. 10.1016/0092-640X(88)90044-710.1016/0092-640X(88)90044-7 ↗
13. 10.1016/0022-3115(76)90024-610.1016/0022-3115(76)90024-6 ↗
14. 10.1016/0092-640X(82)90002-X10.1016/0092-640X(82)90002-X ↗
15. 10.1002/sca.495012040710.1002/sca.4950120407 ↗
16. Waldo · 1988 · 310
17. 10.1017/S143192762000128210.1017/S1431927620001282 ↗
18. 10.1016/j.jnucmat.2011.09.00310.1016/j.jnucmat.2011.09.003 ↗
19. 10.1016/0022-3115(61)90196-910.1016/0022-3115(61)90196-9 ↗
20. 10.1016/j.susc.2007.05.03210.1016/j.susc.2007.05.032 ↗
21. Farthing · 1990
22. 10.1111/j.1365-2818.1984.tb00519.x10.1111/j.1365-2818.1984.tb00519.x ↗
23. Quantitative microprobe analysis of uranium minerals
24. The role of carbon film thickness in electron microprobe analysis
25. Pouchou, J-L & Pichoir, F (1988). Determination of mass absorption coefficients for soft x-rays by use of the electron microprobe. In Microbeam Analysis 1988: Proceedings of the 23rd Annual Conference of the Microbeam Analysis Society, Milwaukee, Wisconsin, August 8–12, 1988, Newbury DE (Ed.), pp. 319–324. San Francisco: San Francisco Press.
26. 10.1017/S143192760999040710.1017/S1431927609990407 ↗
27. 10.1017/S143192761800019310.1017/S1431927618000193 ↗
28. Holley, C (1965). Thermodynamics and transport properties of uranium dioxide and related phases. Vienna. Available at: http://www.iaea.org/inis/collection/NCLCollectionStore/_Public/24/071/24071477.pdf.
29. 10.1021/jp062795n10.1021/jp062795n ↗
30. 10.1016/j.jnucmat.2005.04.06010.1016/j.jnucmat.2005.04.060 ↗
31. 10.1002/sca.495011040410.1002/sca.4950110404 ↗
32. 10.1017/S143192761801539810.1017/S1431927618015398 ↗
33. 10.1017/S143192761901471510.1017/S1431927619014715 ↗
34. Heinrich · 1986 · 67
35. 10.1103/RevModPhys.39.7810.1103/RevModPhys.39.78 ↗
36. 10.1016/0022-3115(67)90106-710.1016/0022-3115(67)90106-7 ↗
37. 10.1103/RevModPhys.39.12510.1103/RevModPhys.39.125 ↗
38. 10.1017/S143192761601171510.1017/S1431927616011715 ↗
39. 10.1017/S143192761100399010.1017/S1431927611003990 ↗
40. Matthews, MB (2016). Performance characteristics of WDS and EDS detectors. In 12th EMAS Regional Workshop on Electron Probe Microanalysis of Materials Today, May 8–11, 2016, Podor R (Ed.), pp. 83–114. Bagnols-sur-Cèze: EMAS and CEA Marcoule.
41. Pinard, PT (2016). Electron Probe Microanalysis of Carbon Containing Steels at a High Spatial Resolution. RWTH Aachen University. Available at: http://publications.rwth-aachen.de/record/673259/files/673259.pdf.
42. 10.1088/1757-899X/109/1/01200910.1088/1757-899X/109/1/012009 ↗
43. On x-ray wave-lengths10.1103/PhysRev.6.166 ↗
44. Quantitative analysis of the plutonium-iron system
45. 10.1016/S0022-3115(99)00108-710.1016/S0022-3115(99)00108-7 ↗
46. Merlet, C (1998). Quantification procedures in EPMA. In Electron Probe Microanalysis Today: Practical Aspects. Proceedings 3rd Regional Workshop EMAS, Llovet X, Merlet C & Salvat F (Eds.), pp. 176–191. Barcelona: Universitat de Barcelona.
47. 10.1088/0022-3727/7/15/31910.1088/0022-3727/7/15/319 ↗
48. Busker · 2002
49. Colby · 1963
50. 10.1016/S0022-3115(97)00343-710.1016/S0022-3115(97)00343-7 ↗
51. Colby · 1966 · 95
52. 10.1515/zna-1981-122210.1515/zna-1981-1222 ↗
53. Salvat, F (2015). PENELOPE-2014: A code system for Monte Carlo simulation of electron and photon transport. Available at: http://www.oecd-nea.org/lists/penelope.html.