journal article·2019-02

The f-Ratio Quantification Method for X-ray Microanalysis Applied to Mg–Al–Zn Alloys

Chaoyi Teng, Hendrix Demers, Xin Chu, Raynald Gauvin

Microscopy and Microanalysis· Volume 25· Issue 1
Publisher page

Abstract

Abstract The f-ratio quantitative X-ray microanalysis method has been recently developed for binary systems based on a scanning electron microscope/energy dispersive spectroscopy (SEM/EDS) system. This method incorporates traditional EDS experiments and Monte Carlo simulations, and calibration factors are calculated with standard samples to evaluate the differences between them. In this work, the f-ratio method was extended to Mg–Al–Zn multi-element systems using a cold field emission SEM and a tungsten emission SEM. Results show that the stability of the beam current does not influence the f-ratio quantification accuracy. Thus, the f-ratio method is suitable for quantitative X-ray mapping with a long-time acquisition or even an unstable beam current. Comparing with other quantitative techniques including the routine standardless analysis and the standard-based k-ratio method, the f-ratio method is a simple and accurate quantification method.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Advanced Materials Characterization Techniques · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. 10.1103/PhysRev.67.32110.1103/PhysRev.67.321 ↗
2. 10.1063/1.55597410.1063/1.555974 ↗
3. 10.1002/sca.495011040410.1002/sca.4950110404 ↗
4. 10.1017/S143192761009401810.1017/S1431927610094018 ↗
5. Goldstein · 1981
6. 10.1017/S155192951000132X10.1017/S155192951000132X ↗
7. Henoc · 1976 · 61
8. 10.1007/s10853-014-8685-210.1007/s10853-014-8685-2 ↗
9. 10.1021/ac00107a01710.1021/ac00107a017 ↗
10. 10.1016/j.jallcom.2015.09.20110.1016/j.jallcom.2015.09.201 ↗
11. 10.1107/S0365110X5700080810.1107/S0365110X57000808 ↗
12. 10.1063/1.132105510.1063/1.1321055 ↗
13. Horny P (2006). Development of a quantification method for X-ray microanalysis with an electron microscope . Ph.D. Thesis. McGill University, Montreal, QC, Canada.
14. 10.1017/S143192761201048310.1017/S1431927612010483 ↗
15. The multiple scattering of electrons
16. 10.1016/S1359-6454(01)00162-810.1016/S1359-6454(01)00162-8 ↗
17. 10.1063/1.35766910.1063/1.357669 ↗
18. 10.1088/0022-3700/15/1/02210.1088/0022-3700/15/1/022 ↗
19. 10.1016/j.micron.2006.11.00410.1016/j.micron.2006.11.004 ↗
20. 10.1063/1.34640010.1063/1.346400 ↗
21. 10.1016/j.scriptamat.2006.10.03510.1016/j.scriptamat.2006.10.035 ↗
22. 10.1017/S143192760909242310.1017/S1431927609092423 ↗
23. 10.1002/sca.2104110.1002/sca.21041 ↗
24. 10.1017/S155192951100085X10.1017/S155192951100085X ↗
25. 10.1017/S143192761200110910.1017/S1431927612001109 ↗
26. 10.1017/S143192761800041710.1017/S1431927618000417 ↗
27. 10.1111/j.1365-2818.1975.tb03895.x10.1111/j.1365-2818.1975.tb03895.x ↗
28. Prospects for higher spatial resolution quantitative X-ray analysis using transition element L-lines
29. 10.6028/jres.107.04910.6028/jres.107.049 ↗
30. 10.1002/sca.2000010.1002/sca.20000 ↗
31. Castaing R (1951). Application of electron probes to local chemical and crystallographic analysis . Ph.D. Thesis. University of Paris. California Institute of Technology, Pasadena, California, USA.