Superficial and Inner Examination of a Microwave-Irradiated Dental Acrylic Resin and Its Metal–Polymer Interface
Source abstract
Abstract
Abstract The aim of this study is to conduct an extended surface and cross-section characterization of a denture base acrylic resin subjected to 500, 650, and 750 W microwave irradiation for 2, 3, and 5 min to assess its morphological modifications. A commercial heat-cured powder was polymerized according to the manufacturer’s specifications and distributed into 20 circular samples. A stainless-steel wire was partially embedded in half of the discs, in order to investigate the metal–polymer interface. High-resolution scanning electron microscopy (SEM) imaging, white light interferometry, roughness measurements and Fourier transform infrared spectrometry were employed for morphological and structural evaluation of the irradiated polymer. Superficial adaptation was discovered after 5 min exposure at 500 W, 650 W, and 750 W, revealing significant roughness correction for 750 W. SEM characterization revealed the inner alteration of the resin for the 750 W protocol and a metal–polymer gap developed regardless of the irradiation conditions. The considerable temperature fluctuations that the samples were subject to during the experiments did not essentially change the poly(methyl-methacrylate) bond structure.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Scientific and Engineering Research Topics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (51)
Show source-provided references
1. 10.1067/mpr.2002.12449010.1067/mpr.2002.124490 ↗
2. 10.1016/j.prosdent.2005.03.01410.1016/j.prosdent.2005.03.014 ↗
3. 10.1111/j.1365-2842.1992.tb01580.x10.1111/j.1365-2842.1992.tb01580.x ↗
4. 10.1002/app.2712010.1002/app.27120 ↗
5. 10.1111/j.1439-0507.2008.01558.x10.1111/j.1439-0507.2008.01558.x ↗
6. 10.14219/jada.archive.1985.025010.14219/jada.archive.1985.0250 ↗
7. The effect of glutaraldehyde and microwave disinfection on some properties of acrylic denture resin
8. 10.1111/j.1532-849X.2004.04002.x10.1111/j.1532-849X.2004.04002.x ↗
9. Phoenix · 2003 · 721
10. 10.1111/j.1532-849X.2007.00264.x10.1111/j.1532-849X.2007.00264.x ↗
11. 10.1590/S0103-6440200500020000610.1590/S0103-64402005000200006 ↗
12. 10.1111/j.1532-849X.2007.00277.x10.1111/j.1532-849X.2007.00277.x ↗
13. Effect of repeated microwave disinfection on surface roughness and baseplate adaptation of denture resins polymerized by different techniques
14. 2012
15. Linear dimensional change in acrylic resin disinfected by microwave energy
16. 10.3390/ma806322110.3390/ma8063221 ↗
17. 10.1016/S0022-3913(09)60200-610.1016/S0022-3913(09)60200-6 ↗
18. Rizzatti-Barbosa · 2011 · 423
19. Rawls · 2012 · 92
20. 10.1016/S0022-3913(09)60120-710.1016/S0022-3913(09)60120-7 ↗
21. 10.1016/S0022-3913(97)70148-310.1016/S0022-3913(97)70148-3 ↗
22. 10.1016/j.prosdent.2005.04.01710.1016/j.prosdent.2005.04.017 ↗
23. Effectiveness of microwave irradiation on the disinfection of complete dentures
24. 10.1016/S0109-5641(03)00084-810.1016/S0109-5641(03)00084-8 ↗
25. 10.1111/j.1532-849X.2011.00770.x10.1111/j.1532-849X.2011.00770.x ↗
26. 10.1111/jopr.1220310.1111/jopr.12203 ↗
27. Craig · 2002 · 18
28. 10.1111/j.1532-849X.2009.00489.x10.1111/j.1532-849X.2009.00489.x ↗
29. The effect of microwave disinfection on surface roughness and hardness of hot, cold acrylic resin and soft liner in different conditions
30. Vergani · 2011 · 63
31. Effect of microwave disinfection on transverse strength and hardness of acrylic resin denture base materials10.33899/rden.2011.45459 ↗
32. 10.1016/S0022-3913(99)70250-710.1016/S0022-3913(99)70250-7 ↗
33. 10.1016/S0022-3913(98)70161-110.1016/S0022-3913(98)70161-1 ↗
34. 10.14219/jada.archive.2012.015210.14219/jada.archive.2012.0152 ↗
35. 10.1016/S0022-3913(05)80061-710.1016/S0022-3913(05)80061-7 ↗
36. Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection
37. 10.1590/S0103-6440200600030000410.1590/S0103-64402006000300004 ↗
38. 10.1002/jbm.b.3102710.1002/jbm.b.31027 ↗
39. Effectiveness of microwave sterilization on three hard chairside reline resins
40. Effect of two microwave disinfection protocols on adaptation of poly (methyl methacrylate) denture bases
41. 10.1080/0001635080216561410.1080/00016350802165614 ↗
42. 10.1016/j.mee.2010.08.02910.1016/j.mee.2010.08.029 ↗
43. 10.1046/j.1365-2842.1998.00266.x10.1046/j.1365-2842.1998.00266.x ↗
44. 10.1590/S0103-6440200600020000710.1590/S0103-64402006000200007 ↗
45. 10.1155/2011/94156110.1155/2011/941561 ↗
46. Biocompatible denture polymers—A review
47. 10.1590/S0103-6440200800040001110.1590/S0103-64402008000400011 ↗
48. 10.1016/j.prosdent.2004.01.00610.1016/j.prosdent.2004.01.006 ↗
49. 10.1016/S0022-3913(07)60058-410.1016/S0022-3913(07)60058-4 ↗
50. Comparative evaluation of surface porosities in conventional heat polymerized acrylic resin cured by water bath and microwave energy with microwavable acrylic resin cured by microwave energy10.4103/0976-237X.114844 ↗
51. Sakaguchi · 2012 · 161