Abstract
Abstract All clinically-approved and many novel gadolinium (Gd)-based contrast agents used to enhance signal intensity in magnetic resonance imaging (MRI) are optically silent. To verify MRI results, a “gold standard” that can map and quantify Gd down to the parts per million (ppm) levels is required. Nuclear microscopy is a relatively new technique that has this capability and is composed of a combination of three ion beam techniques: scanning transmission ion microscopy, Rutherford backscattering spectrometry, and particle induced X-ray emission used in conjunction with a high energy proton microprobe. In this proof-of-concept study, we show that in diseased aortic vessel walls obtained at 2 and 4 h after intravenous injection of the myeloperoxidase-senstitive MRI agent, bis-5-hydroxytryptamide-diethylenetriamine-pentaacetate gadolinium, there was a time-dependant Gd clearance (2 h = 18.86 ppm, 4 h = 8.65 ppm). As expected, the control animal, injected with the clinically-approved conventional agent diethylenetriamine-pentaacetate gadolinium and sacrificed 1 week after injection, revealed no significant residual Gd in the tissue. Similar to known in vivo Gd pharmacokinetics, we found that Gd concentration dropped by a factor of 2 in vessel wall tissue in 1.64 h. Further high-resolution studies revealed that Gd was relatively uniformly distributed, consistent with random agent diffusion. We conclude that nuclear microscopy is potentially very useful for validation studies involving Gd-based magnetic resonance contrast agents.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Lanthanide and Transition Metal Complexes · Advanced MRI Techniques and Applications · MRI in cancer diagnosis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. 10.1016/S0168-583X(03)01003-610.1016/S0168-583X(03)01003-6 ↗
2. 10.3349/ymj.2000.41.6.74010.3349/ymj.2000.41.6.740 ↗
3. 10.1021/ac070662810.1021/ac0706628 ↗
4. 10.1021/ol050208v10.1021/ol050208v ↗
5. 10.1039/b601540a10.1039/b601540a ↗
6. Mayer M. (1997). Simnra Users' Guide. Technical Report IPP 9/113, Max-Planck Institut for Plasmaphysik, Garching, Germany.
7. 10.1016/0168-583X(89)90042-610.1016/0168-583X(89)90042-6 ↗
8. Johansson · 1995
9. 10.1161/01.ATV.14.1.9510.1161/01.ATV.14.1.95 ↗
10. 10.1016/S0014-5793(00)02227-410.1016/S0014-5793(00)02227-4 ↗
11. 10.1016/j.ejrad.2006.06.02110.1016/j.ejrad.2006.06.021 ↗
12. 10.1097/01.rli.0000124455.11402.5210.1097/01.rli.0000124455.11402.52 ↗
13. 10.1161/CIRCULATIONAHA.107.75651010.1161/CIRCULATIONAHA.107.756510 ↗
14. 10.1073/pnas.080394510510.1073/pnas.0803945105 ↗
15. 10.1002/cmmi.13710.1002/cmmi.137 ↗
16. 10.2174/18715200778061813510.2174/187152007780618135 ↗
17. 10.1148/radiol.240205099410.1148/radiol.2402050994 ↗
18. 10.1002/jmri.108210.1002/jmri.1082 ↗
19. 10.1002/jmri.2022810.1002/jmri.20228 ↗
20. 10.1161/01.ATV.14.1.10510.1161/01.ATV.14.1.105 ↗
21. 10.1002/jmri.2111310.1002/jmri.21113 ↗
22. 10.1148/radiology.183.1.154965310.1148/radiology.183.1.1549653 ↗
23. 10.1111/j.1472-8206.2006.00447.x10.1111/j.1472-8206.2006.00447.x ↗
24. 10.1016/j.nimb.2006.03.07310.1016/j.nimb.2006.03.073 ↗