Multiple Double Cross-Section Transmission Electron Microscope Sample Preparation of Specific Sub-10 nm Diameter Si Nanowire Devices
Source abstract
Abstract
Abstract The ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Materials Characterization Techniques · Semiconductor materials and interfaces · Integrated Circuits and Semiconductor Failure Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. McIlwrath · 2004 · 320
2. 10.1016/S0304-3991(00)00096-610.1016/S0304-3991(00)00096-6 ↗
3. 10.1557/mrs2007.6310.1557/mrs2007.63 ↗
4. 10.1016/S0026-2714(01)00174-310.1016/S0026-2714(01)00174-3 ↗
5. 10.1093/jmicro/dfh08910.1093/jmicro/dfh089 ↗
6. 10.1017/S143192760909615910.1017/S1431927609096159 ↗
7. Bangsaruntip · 2009 · 1
8. Application of 3-D transmission electron microscopy in semiconductor device analysis
9. 10.1016/j.apsusc.2004.09.09210.1016/j.apsusc.2004.09.092 ↗
10. Bangsaruntip · 2010 · 21
11. 10.1017/S155192950005381510.1017/S1551929500053815 ↗
12. Transmission electron microscope sample preparation using a focused ion beam
13. A FIB micro-sampling technique and a site-specific TEM sample preparation method for precision materials characterization10.1557/PROC-636-D9.35.1 ↗
14. 10.1017/S155192950005082310.1017/S1551929500050823 ↗
15. 10.1116/1.58179510.1116/1.581795 ↗
16. 10.1063/1.243663310.1063/1.2436633 ↗
17. Wang · 2002 · 765
18. 10.1017/S143192760707084510.1017/S1431927607070845 ↗
19. 10.1016/S0304-3991(99)00055-810.1016/S0304-3991(99)00055-8 ↗