Rapid-Acquisition Fluctuation Electron Microscopy: Decoherence and the Dominant Role of Noise
Source abstract
Abstract
Abstract We investigate how data acquisition rate affects the decoherence of diffraction speckles in fluctuation electron microscopy (FEM) experiments on amorphous silicon at 80 kV. Surprisingly, reducing acquisition time from 256 ms to 1 ms does not significantly enhance the intensity variance peaks related to medium-range order. This suggests that decoherence processes operate at timescales faster than 1 ms. At the highest acquisition rates, noise complicates the variance background estimation. A significant source of non-Poisson noise is the spread of electron signals across adjacent detector pixels. We mostly restore the discrete pulse counting needed to mitigate Poisson noise by rounding pixel intensity to the nearest integer-electron value. However, a residual negative-variance offset grows as the acquisition rate increases. Efficient electron pulse counting in detectors is crucial for processing Poisson noise in FEM, especially with weak signals.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Electron Microscopy Techniques and Applications · Electron and X-Ray Spectroscopy Techniques · Surface and Thin Film Phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Physics, Arizona State University , Tempe, AZ 85287 ,
Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Forschungszentrum Jülich , Jülich 52425 ,
Mechanical Engineering, FAMU-FSU College of Engineering , 2525 Pottsdamer Street, Tallahassee, FL 32303 ,
Characterization Sciences Department, Corning Inc. , 184 Science Center Drive, Painted Post, NY 14870 ,
Funding
NSF
References (40)
Show source-provided references
1. Medium-range order in amorphous silicon investigated by constrained structural relaxation of two-body and four-body electron diffraction data10.1016/j.actamat.2011.09.039 ↗
2. Born · 2013
3. The study of nanovolumes of amorphous materials using electron scattering10.1146/matsci.2007.37.issue-1 ↗
4. Electron diffraction analysis of polycrystalline and amorphous thin films10.1107/S0108767388004957 ↗
5. Dainty · 1975 · 255
6. Nanobeam diffraction fluctuation electron microscopy technique for structural characterization of disordered materials–application to AL88-xY7Fe5Tix metallic glasses10.1016/j.ultramic.2010.05.010 ↗
7. Gibson · 1979
8. Beam transit effects in single molecule coherent diffraction10.1103/PhysRevB.78.245401 ↗
9. Probability density function of the sum of n partially correlated speckle patterns10.1016/0030-4018(75)90091-7 ↗
10. Goodman · 1975 · 60
11. Momentum transfer resolved electron correlation microscopy10.1016/j.ultramic.2023.113886 ↗
12. Electron beam damage in oxides: A review10.1088/0034-4885/79/1/016501 ↗
13. Beam damage by the induced electric field in transmission electron microscopy10.1016/j.micron.2016.02.007 ↗
14. Electron irradiation effects in transmission electron microscopy: Random displacements and collective migrations10.1016/j.micron.2023.103482 ↗
15. Local chemical and topological order in AL–TB and its role in controlling nanocrystal formation10.1016/j.actamat.2011.11.008 ↗
16. Analysis of spatial point patterns in electron-counting images10.1093/jmicro/dfac006 ↗
17. Electron dose dependence of signal-to-noise ratio, atom contrast and resolution in transmission electron microscope images10.1016/j.ultramic.2014.01.010 ↗
18. Direct detectors and their applications in electron microscopy for materials science10.1088/2515-7639/ac0ff9 ↗
19. FEMSIM + HRMC: Simulation of and structural refinement using fluctuation electron microscopy for amorphous materials10.1016/j.cpc.2016.12.006 ↗
20. Resolution beyond the “information limit” in transmission electron microscopy10.1038/374630a0 ↗
21. Four-dimensional scanning transmission electron microscopy (4D-stem): From scanning nanodiffraction to ptychography and beyond10.1017/S1431927619000497 ↗
22. Press · 1992
23. Fluctuation electron microscopy on silicon amorphized at varying self ion-implantation conditions10.1063/1.5107494 ↗
24. Treating knock-on displacements in fluctuation electron microscopy experiments10.1017/S1431927622012417 ↗
25. Speckle suppression by decoherence in fluctuation electron microscopy10.1017/S1431927615015135 ↗
26. Quantitative characterization of electron detectors for transmission electron microscopy10.1016/j.jsb.2013.10.016 ↗
27. Charge accumulation in electron cryomicroscopy10.1016/j.ultramic.2018.01.009 ↗
28. NIH image to imageJ: 25 years of image analysis10.1038/nmeth.2089 ↗
29. High dynamic range pixel array detector for scanning transmission electron microscopy10.1017/S1431927615015664 ↗
30. Treacy · 201210.1002/9783527641864.ch12 ↗
31. The local structure of amorphous silicon10.1126/science.1214780 ↗
32. Variable coherence microscopy: A rich source of structural information from disordered materials10.1107/S0108767395012876 ↗
33. Treacy · 1998 · 433
34. Examination of a polycrystalline thin-film model to explore the relation between probe size and structural correlation length in fluctuation electron microscopy10.1017/S1431927611012517 ↗
35. Fluctuation microscopy: A probe of medium range order10.1088/0034-4885/68/12/R06 ↗
36. Paracrystallites found in evaporated amorphous tetrahedral semiconductors10.1016/S0022-3093(98)00371-8 ↗
37. Beam effects on atomic dynamics in metallic glasses studied with electron correlation microscopy10.1093/micmic/ozad110 ↗
38. Computer generation of structural models of amorphous Si and Ge10.1103/PhysRevLett.54.1392 ↗
39. Effect of sample thickness, energy filtering, and probe coherence on fluctuation electron microscopy experiments10.1016/j.ultramic.2011.05.004 ↗
40. Estimating illumination coherence width from focused-probe intensity profiles10.1017/S1431927621002981 ↗