Alternative Forward Models for Imaging Thick Specimens in Transmission Electron Microscopy
Source abstract
Abstract
Abstract I have investigated two different forward models for image formation in transmission electron microscopy of thick specimens, the 3DCtf model, which introduces a defocus gradient in the linear approximation, and the multislice model. An important result is that the 3DCtf model does not seem to be compatible with the multislice image formation model. A second very useful finding is that the exit wave in the multislice model has an imaginary part, which, in first-order approximation, is a pure projection of the specimen and is not affected by the defocus gradient. The defocus gradient only comes into play in real valued and higher-order imaginary terms. If the multislice model is closer to reality than the 3DCtf-model, then the best way to retrieve the specimen projection for thicker specimens should be a procedure for retrieving the exit wave's imaginary term, for example using images recorded at different defocus values.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Electron Microscopy Techniques and Applications · Advanced X-ray Imaging Techniques · Electron and X-Ray Spectroscopy Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Engineering Sciences in Chemistry, Biotechnology and Health, Royal Institute of Technology , Hälsovägen 11 C, 14152 Huddinge , Sweden
References (12)
Show source-provided references
1. Cowley · 1995
2. Frank · 200610.1093/acprof:oso/9780195182187.001.0001 ↗
3. SimulaTEM: Multislice simulations for general objects10.1016/j.ultramic.2009.09.010 ↗
4. Defocus-gradient corrected back-projection10.1016/S0304-3991(00)00005-X ↗
5. Limitations of the linear and the projection approximations in three-dimensional transmission electron microscopy of fully hydrated proteins10.1111/jmi.12253 ↗
6. The Khoros software development environment for image and signal processing10.1109/83.287018 ↗
7. On the validity of the weak-phase and other approximations in the analysis of electron microscope images10.1088/0022-3727/9/13/006 ↗
8. Comparison of phase contrast transmission electron microscopy with optimized scanning transmission annular dark field imaging for protein imaging10.1016/S0304-3991(02)00436-9 ↗
9. Hydration-layer models for cryo-EM image simulation10.1016/j.jsb.2012.04.021 ↗
10. Electron holography of biological samples10.1016/j.micron.2006.11.012 ↗
11. A fast algorithm for computing and correcting the CTF for tilted, thick specimens in TEM10.1016/j.ultramic.2011.03.001 ↗
12. Image formation modeling in cryo-electron microscopy10.1016/j.jsb.2013.05.008 ↗