Automatic Biological Cell Counting Using a Modified Gradient Hough Transform
Source abstract
Abstract
Abstract We present a computational method for pseudo-circular object detection and quantitative characterization in digital images, using the gradient accumulation matrix as a basic tool. This Gradient Accumulation Transform (GAT) was first introduced in 1992 by Kierkegaard and recently used by Kaytanli & Valentine. In the present article, we modify the approach by using the phase coding studied by Cicconet, and by adding a “local contributor list” (LCL) as well as a “used contributor matrix” (UCM), which allow for accurate peak detection and exploitation. These changes help make the GAT algorithm a robust and precise method to automatically detect pseudo-circular objects in a microscopic image. We then present an application of the method to cell counting in microbiological images.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Cell Image Analysis Techniques · Image and Object Detection Techniques · Digital Imaging for Blood Diseases
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Rad A. A. , Faez K. & Qaragozlou N. (2003). Fast Circle Detection Using Gradient Pair Vectors. In Dicta, pp. 879–888.
2. Tao Z. , Junjie G. & Enxiu S. (2008). An algorithm for fast circular object detection based on discrete evolute distribution. In ISISE’08 International Symposium on Information Science and Engineering, 2008. IEEE, Vol. 1, pp. 321–324.
3. Kumagai S. & Hotta K. (2012). Counting and radius estimation of lipid droplet in intracellular images. In 2012 IEEE International Conference on Systems, Man, and Cybernetics (SMC), IEEE, pp. 67–71.10.1109/ICSMC.2012.6377678 ↗
4. Davies · 2004
5. Cicconet M. , Geiger D. & Werman M. (2015). Complex-valued hough transforms for circles. In 2015 IEEE International Conference on Image Processing (ICIP), IEEE , pp. 2801–2804.10.1109/ICIP.2015.7351313 ↗
6. Asimov · 1954
7. Lehmussola A. , Selinummi J. , Ruusuvuori P. , Niemisto A. & Yli-Harja O. (2006). Simulating fluorescent microscope images of cell populations. In IEEE-EMBS 2005. 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE , pp. 3153–3156.
8. 10.1109/34.100023610.1109/34.1000236 ↗
9. 10.1111/jmi.1200410.1111/jmi.12004 ↗
10. Study on algorithms of graphic element recognition for precise vectorization of industrial computed tomographic image
11. 10.1017/S143192761500066510.1017/S1431927615000665 ↗
12. 10.1147/sj.41.002510.1147/sj.41.0025 ↗
13. Timm F. & Barth E. (2011). Accurate, fast, and robust centre localisation for images of semiconductor components. In IS&T/SPIE Electronic Imaging, International Society for Optics and Photonics, pp. 787705–787705–10.10.1117/12.872386 ↗
14. 10.1007/BF0121271410.1007/BF01212714 ↗
15. A threshold selection method from gray-level histograms
16. Variations of box plots10.1080/00031305.1978.10479236 ↗
17. 10.3109/09553002.2011.62203310.3109/09553002.2011.622033 ↗