journal article·2022-12-01Open access

Treating Knock-On Displacements in Fluctuation Electron Microscopy Experiments

Dražen Radić, Martin Peterlechner, Matthias Posselt, Hartmut Bracht

Microscopy and Microanalysis· Volume 28· Issue 6

Abstract

Abstract This work investigates how knock-on displacements influence fluctuation electron microscopy (FEM) experiments. FEM experiments were conducted on amorphous silicon, formed by self-ion implantation, in a transmission electron microscope at 300 kV and 60 kV at various electron doses, two different binnings and with two different cameras, a CCD and a CMOS one. Furthermore, energy filtering has been utilized in one case. Energy filtering greatly enhances the FEM data by removing the inelastic background intensity, leading to an improved speckle contrast. The CMOS camera yields a slightly larger normalized variance than the CCD at an identical electron dose and appears more prone to noise at low electron counts. Beam-induced atomic displacements affect the 300 kV FEM data, leading to a continuous suppression of the normalized variance with increasing electron dose. Such displacements are considerably reduced for 60 kV experiments since the primary electron's maximum energy transfer to an atom is less than the displacement threshold energy of amorphous silicon. The results show that the variance suppression due to knock-on displacements can be controlled in two ways: Either by minimizing the electron dose to the sample or by conducting the experiment at a lower acceleration voltage.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Semiconductor materials and devices · Silicon Nanostructures and Photoluminescence · Semiconductor materials and interfaces

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

University of Münster Institute of Materials Physics, , 48149 Münster, Germany

Helmholtz-Zentrum Dresden-Rossendorf , 01328 Dresden, Germany

Funding

Deutsche Forschungsgemeinschaft

References (33)

Show source-provided references
1. Irradiation damage in germanium and silicon due to electrons and gamma rays10.1063/1.1735310 ↗
2. Density of amorphous Si10.1063/1.111121 ↗
3. Nanobeam diffraction fluctuation electron microscopy technique for structural characterization of disordered materials—application to Al88−xY7Fe5Tix metallic glasses10.1016/j.ultramic.2010.05.010 ↗
4. Medium range order of bulk metallic glasses determined by variable resolution fluctuation electron microscopy10.1016/j.micron.2012.02.006 ↗
5. Radiation damage in the TEM and SEM10.1016/j.micron.2004.02.003 ↗
6. Fluctuation X-ray microscopy: A novel approach for the structural study of disordered materials10.1111/j.1365-2818.2007.01714.x ↗
7. Atom pair persistence in disordered materials from fluctuation microscopy10.1016/S0304-3991(00)00013-9 ↗
8. Diminished medium-range order observed in annealed amorphous germanium10.1103/PhysRevLett.78.1074 ↗
9. Atomic displacements in solids by nuclear radiation10.1146/annurev.ns.12.120162.001331 ↗
10. Electron correlation microscopy: A new technique for studying local atom dynamics applied to a supercooled liquid10.1017/S1431927615000641 ↗
11. Threshold defect production in silicon determined by density functional theory molecular dynamics simulations10.1103/PhysRevB.78.045202 ↗
12. Nanoscale structure and structural relaxation in Zr50Cu45A5 bulk metallic glass10.1103/PhysRevLett.108.195505 ↗
13. Variable resolution fluctuation electron microscopy on Cu-Zr metallic glass using a wide range of coherent STEM probe size10.1017/S1431927610094109 ↗
14. The displacement of atoms in solids by radiation10.1088/0034-4885/18/1/301 ↗
15. Self-diffusion in amorphous silicon by local bond rearrangements10.1103/PhysRevLett.120.225902 ↗
16. Using fluctuation microscopy to characterize structural order in metallic glasses10.1017/S1431927603030459 ↗
17. Quantitative fluctuation electron microscopy in the STEM: Methods to identify, avoid, and correct for artifacts10.1017/S1431927614012756 ↗
18. EELS log-ratio technique for specimen-thickness measurement in the TEM10.1002/jemt.1060080206 ↗
19. The coulomb scattering of relativistic electrons by nuclei10.1103/PhysRev.74.1759 ↗
20. Probe current determination in analytical TEM/STEM and its application to the characterization of large area EDS detectors10.1002/jemt.22551 ↗
21. The scattering of fast electrons by atomic nuclei10.1098/rspa.1929.0127 ↗
22. Comparison of experimental STEM conditions for fluctuation electron microscopy10.1017/S143192762002440X ↗
23. Speckle suppression by decoherence in fluctuation electron microscopy10.1017/S1431927615015135 ↗
24. Seitz · 1956
25. Examination of a polycrystalline thin-film model to explore the relation between probe size and structural correlation length in fluctuation electron microscopy10.1017/S1431927611012517 ↗
26. Paracrystallites found in evaporated amorphous tetrahedral semiconductors10.1016/S0022-3093(98)00371-8 ↗
27. Variable coherence microscopy: A rich source of structural information from disordered materials10.1107/S0108767395012876 ↗
28. Fluctuation microscopy: A probe of medium range order10.1088/0034-4885/68/12/R06 ↗
29. Fluctuation microscopy in the STEM10.1016/S0304-3991(02)00155-9 ↗
30. Fluctuation microscopy: A probe of atomic correlations in disordered materials10.1093/oxfordjournals.jmicro.a023805 ↗
31. Flexible formation of coherent probes on an aberration-corrected STEM with three condensers10.1093/jmicro/dfq052 ↗
32. Effect of sample thickness, energy filtering, and probe coherence on fluctuation electron microscopy experiments10.1016/j.ultramic.2011.05.004 ↗
33. Analytical and computational modeling of fluctuation electron microscopy from a nanocrystal/amorphous composite10.1016/j.ultramic.2012.07.022 ↗