journal article·2012-10

Three-Dimensional Morphology of Microdamage in Peri-Screw Bone: A Scanning Electron Microscopy of Methylmethacrylate Cast Replica

Lei Wang, Jin Shao, Tingjun Ye, Lianfu Deng, Shijing Qiu

Microscopy and Microanalysis· Volume 18· Issue 5
Publisher page

Abstract

Abstract Screw implantation inevitably causes microdamage in surrounding bone. However, little is known about the detailed characteristics of microdamage in peri-screw bone. In this study, we developed a method to construct microdamage cast with methylmethacrylate (MMA) and observed the cast using scanning electron microscopy (SEM). In basic fuchsin stained bone sections observed by bright-field and fluorescence microscopy, diffuse damage, cross-hatched damage, and linear cracks were all presented in peri-screw bone. Using MMA casting/SEM method, we found numerous densely packed microcracks in the areas with diffuse damage. The osteocyte canaliculi and the microcracks consisting of diffuse damage had a similar diameter (or width), usually <0.5 μm, but their morphology was largely different. In the area with cross-hatched damage, the orientation of microcracks was similar to that in diffuse damage, but the number was significantly decreased. Many microcracks were thicker than 1 μm and associated with a rough surface. Large linear cracks (∼10 μm in diameter) occurred in different areas. Plenty of microcracks were present on the surface of some linear cracks. In conclusion, the MMA casting/SEM method can demonstrate the three-dimensional morphology of different types of microdamage, particularly the microcracks in diffuse damage, which are unable to be shown by light microscopy.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. 10.1093/humrep/der45810.1093/humrep/der458 ↗
2. 10.1111/j.1600-0501.2004.01081.x10.1111/j.1600-0501.2004.01081.x ↗
3. 10.1385/MB:16:2:12710.1385/MB:16:2:127 ↗
4. 10.1016/8756-3282(94)90271-210.1016/8756-3282(94)90271-2 ↗
5. 10.1016/S0940-9602(98)80126-X10.1016/S0940-9602(98)80126-X ↗
6. 10.1016/j.ijfatigue.2006.09.01010.1016/j.ijfatigue.2006.09.010 ↗
7. 10.1046/j.1469-7580.1998.19320179.x10.1046/j.1469-7580.1998.19320179.x ↗
8. 10.1046/j.1469-7580.2000.19730413.x10.1046/j.1469-7580.2000.19730413.x ↗
9. 10.1016/S0021-9290(00)00090-710.1016/S0021-9290(00)00090-7 ↗
10. 10.1016/S8756-3282(98)00111-210.1016/S8756-3282(98)00111-2 ↗
11. 10.1097/00008505-199500440-0000210.1097/00008505-199500440-00002 ↗
12. The vascular system of human fetal long bones: A scanning electron microscope study of corrosion casts
13. 10.1097/BOT.0b013e318176191f10.1097/BOT.0b013e318176191f ↗
14. 10.1016/S8756-3282(95)00241-310.1016/S8756-3282(95)00241-3 ↗
15. 10.1115/1.140782810.1115/1.1407828 ↗
16. 10.1902/jop.2002.73.3.32210.1902/jop.2002.73.3.322 ↗
17. 10.1046/j.1469-7580.2003.00211.x10.1046/j.1469-7580.2003.00211.x ↗
18. SEM of micro-corrosion casts
19. 10.1016/S8756-3282(99)00151-910.1016/S8756-3282(99)00151-9 ↗
20. 10.1007/s00198-003-1476-210.1007/s00198-003-1476-2 ↗
21. 10.1111/j.1600-0501.2010.02024.x10.1111/j.1600-0501.2010.02024.x ↗
22. 10.1017/S143192761000009710.1017/S1431927610000097 ↗
23. 10.1016/S0021-9290(99)00047-010.1016/S0021-9290(99)00047-0 ↗
24. 10.1111/j.1600-0501.2009.01808.x10.1111/j.1600-0501.2009.01808.x ↗
25. 10.1002/jemt.2026310.1002/jemt.20263 ↗
26. 10.1016/S0021-9290(03)00066-610.1016/S0021-9290(03)00066-6 ↗
27. 10.1364/OL.10.00005310.1364/OL.10.000053 ↗
28. 10.1016/j.bone.2006.09.02710.1016/j.bone.2006.09.027 ↗
29. 10.1016/j.bone.2010.07.00610.1016/j.bone.2010.07.006 ↗
30. 10.1016/j.micron.2005.07.00610.1016/j.micron.2005.07.006 ↗
31. 10.1016/S8756-3282(99)00253-710.1016/S8756-3282(99)00253-7 ↗
32. 10.1002/ar.109212040310.1002/ar.1092120403 ↗
33. 10.1046/j.1469-7580.1997.19120259.x10.1046/j.1469-7580.1997.19120259.x ↗
34. Why bones bend but don't break
35. 10.1111/j.1365-2818.1978.tb00085.x10.1111/j.1365-2818.1978.tb00085.x ↗
36. 10.1016/8756-3282(95)00370-310.1016/8756-3282(95)00370-3 ↗
37. 10.1046/j.1365-2818.1999.00478.x10.1046/j.1365-2818.1999.00478.x ↗
38. Effect of thread design on microdamage creation in cortical bone. In
39. 10.1016/j.bone.2005.01.02310.1016/j.bone.2005.01.023 ↗
40. 10.1007/s11914-005-0002-110.1007/s11914-005-0002-1 ↗
41. 10.1016/8756-3282(90)90087-F10.1016/8756-3282(90)90087-F ↗
42. 10.1359/jbmr.1997.12.1.610.1359/jbmr.1997.12.1.6 ↗
43. 10.1016/S0021-9290(98)00016-510.1016/S0021-9290(98)00016-5 ↗
44. 10.1016/S0021-9290(98)00007-410.1016/S0021-9290(98)00007-4 ↗
45. Presence of microscopic cracks in vivo in bone
46. Hoshaw · 1994 · 735
47. 10.1023/A:101791680042110.1023/A:1017916800421 ↗
48. 10.1017/S143192760102003710.1017/S1431927601020037 ↗
49. 10.1016/1350-4533(94)90039-610.1016/1350-4533(94)90039-6 ↗
50. 10.1016/j.bone.2005.09.00210.1016/j.bone.2005.09.002 ↗
51. 10.1302/0301-620X.84B8.1375210.1302/0301-620X.84B8.13752 ↗