Cost and Capability Compromises in STEM Instrumentation for Low-Voltage Imaging
Source abstract
Abstract
Abstract Low-voltage transmission electron microscopy (≤80 kV) has many applications in imaging beam-sensitive samples, such as metallic nanoparticles, which may become damaged at higher voltages. To improve resolution, spherical aberration can be corrected for in a scanning transmission electron microscope (STEM); however, chromatic aberration may then dominate, limiting the ultimate resolution of the microscope. Using image simulations, we examine how a chromatic aberration corrector, different objective lenses, and different beam energy spreads each affect the image quality of a gold nanoparticle imaged at low voltages in a spherical aberration-corrected STEM. A quantitative analysis of the simulated examples can inform the choice of instrumentation for low-voltage imaging. We here demonstrate a methodology whereby the optimum energy spread to operate a specific STEM can be deduced. This methodology can then be adapted to the specific sample and instrument of the reader, enabling them to make an informed economical choice as to what would be most beneficial for their STEM in the cost-conscious landscape of scientific infrastructure.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Advanced Electron Microscopy Techniques and Applications · Integrated Circuits and Semiconductor Failure Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Trinity College Dublin School of Physics, , Dublin 2, Ireland
Centre for Research on Adaptive Nanostructures & Nanodevices (CRANN) Advanced Microscopy Laboratory, , Dublin 2, Ireland
Funding
Advanced Materials and Bioengineering Research · Science Foundation Ireland
References (48)
Show source-provided references
1. Imaging defect complexes in scanning transmission electron microscopy: Impact of depth, structural relaxation, and temperature investigated by simulations10.1016/j.ultramic.2019.112884 ↗
2. Radiation damage mechanisms of monolayer-protected nanoparticles via TEM analysis10.1021/acs.jpcc.7b08525 ↗
3. Structure retrieval at atomic resolution in the presence of multiple scattering of the electron probe10.1103/PhysRevLett.121.266102 ↗
4. A new method to detect and correct sample tilt in scanning transmission electron microscopy bright-field imaging10.1016/j.ultramic.2016.11.024 ↗
5. High energy and spatial resolution EELS band gap measurements using a Nion monochromated cold field emission HERMES dedicated STEM10.1017/S1431927614002074 ↗
6. Craven · 2011 · 11110.1002/9781119978848.ch6 ↗
7. Prismatic 2.0 — Simulation software for scanning and high resolution transmission electron microscopy (STEM and HRTEM)10.1016/j.micron.2021.103141 ↗
8. The golden age: Gold nanoparticles for biomedicine10.1039/C1CS15237H ↗
9. Choice of operating voltage for a transmission electron microscope10.1016/j.ultramic.2013.10.019 ↗
10. Radiation damage to organic and inorganic specimens in the TEM10.1016/j.micron.2019.01.005 ↗
11. Atomic-resolution imaging with a sub-50-pm electron probe10.1103/PhysRevLett.102.096101 ↗
12. A technical introduction to transmission electron microscopy for soft-matter: Imaging, possibilities, choices, and technical developments10.1002/smll.201906198 ↗
13. Goodhew · 200010.1201/9781482289343 ↗
14. An introduction to high-resolution EELS in transmission electron microscopy10.1007/s11244-008-9101-4 ↗
15. Exploring the capabilities of monochromated electron energy loss spectroscopy in the infrared regime10.1038/s41598-018-23805-5 ↗
16. Electron microscopy image enhanced10.1038/33823 ↗
17. Noble metals on the nanoscale: Optical and photothermal properties and some applications in imaging, sensing, biology, and medicine10.1021/ar7002804 ↗
18. JEOL Ltd. · 2004
19. Three-dimensional optical transfer functions in the aberration-corrected scanning transmission electron microscope10.1111/jmi.12117 ↗
20. Smart align—A new tool for robust non-rigid registration of scanning microscope data10.1186/s40679-015-0008-4 ↗
21. Software techniques for EELS to realize about 0.3 eV energy resolution using 300kV FEG-TEM10.1046/j.1365-2818.2002.01083.x ↗
22. Detection of single atoms and buried defects in three dimensions by aberration-corrected electron microscope with 0.5-Å information limit10.1017/S1431927608080902 ↗
23. TSEM: A review of scanning electron microscopy in transmission mode and Its applications10.1016/B978-0-12-394297-5.00006-4 ↗
24. Reaching a new resolution standard with electron microscopy10.1103/Physics.2.85 ↗
25. Krivanek · 1997
26. Cryogenic transmission electron microscopy (cryo-TEM) for studying the morphology of colloidal drug delivery systems10.1016/j.ijpharm.2011.02.001 ↗
27. Quantitative atomic resolution scanning transmission electron microscopy10.1103/PhysRevLett.100.206101 ↗
28. High-angle scattering of fast electrons from crystals containing heavy elements: Simulation and experiment10.1103/PhysRevB.79.214110 ↗
29. Chromatic aberration correction for atomic resolution TEM imaging from 20 to 80kV10.1103/PhysRevLett.117.076101 ↗
30. Louis · 201210.1142/p815 ↗
31. Development of a practicable digital pulse read-Out for dark-field STEM10.1017/S1431927620024721 ↗
32. Optimizing the environment for sub-0.2nm scanning transmission electron microscopy
33. Room design for high-performance electron microscopy10.1016/j.ultramic.2006.04.017 ↗
34. CryoEM at 100keV: A demonstration and prospects10.1107/S2052252519012612 ↗
35. Probing the internal atomic charge density distributions in real space10.1021/acsnano.8b03712 ↗
36. Aberration-corrected STEM/TEM imaging at 15kV10.1016/j.ultramic.2014.04.006 ↗
37. Evaluation of probe size in STEM imaging at 30 and 60kV10.1016/j.micron.2011.10.010 ↗
38. Atomic-Resolution STEM Imaging of Graphene at Low Voltage of 30 kV with Resolution Enhancement by Using Large Convergence Angle10.1103/PhysRevLett.114.166102 ↗
39. STEM imaging of 47-pm-separated atomic columns by a spherical aberration-corrected electron microscope with a 300-kV cold field emission gun10.1093/jmicro/dfp030 ↗
40. The theoretical resolution limit of the electron microscope10.1063/1.1698233 ↗
41. Intrinsic instability of aberration-corrected electron microscopes10.1103/PhysRevLett.109.163901 ↗
42. Nanoparticles for bioimaging10.1016/j.cis.2006.05.026 ↗
43. Low voltage TEM: Influences on electron energy loss spectrometry experiments10.1016/j.micron.2010.04.007 ↗
44. Design of an objective lens pole piece for a transmission electron microscope with a resolution less than 0.1nm at 200kV10.1016/S0304-3991(97)00125-3 ↗
45. Control of knock-on damage for 3D atomic scale quantification of nanostructures: Making every electron count in scanning transmission electron microscopy10.1103/PhysRevLett.122.066101 ↗
46. A holographic method to measure the source size broadening in STEM10.1016/j.ultramic.2012.05.007 ↗
47. Williams · 200910.1007/978-0-387-76501-3 ↗
48. Facility implementation and comparative performance evaluation of probe-corrected TEM/STEM with Schottky and cold field emission illumination10.1017/S1431927612014298 ↗