An Optimization Method for an Active Multi-Unit Prosthetic Socket with Dynamic Adaptability in Multi-Task Scenarios
Source abstract
Abstract
As a core functional component of the prosthetic system, the prosthetic socket’s adaptability to the residual limb is directly correlated with the prosthetic’s performance, comfort level, and safety profile. Although traditional sockets can satisfy basic suspension requirements, they commonly suffer from inherent drawbacks in practical applications, including uneven pressure distribution, poor air permeability, and inadequate adaptability to the morphological variations of individual residual limbs. To enhance socket adaptability across multi-task scenarios, this study proposes an intelligent physiological adaptation-based optimal design method for active upper-limb prosthetic sockets. Specifically, this method first employs a dynamic force optimization algorithm for multi-contact units oriented to prosthetic manipulation tasks, which real-timely optimizes the output force of each unit under varying external loads to achieve stable socket suspension with minimal interface pressure. Second, biomechanical experiments are conducted to obtain the pain threshold distribution characteristics of forearm soft tissues under compressive loads, thereby providing a physiological basis for the spatial layout of the contact units. Furthermore, the mechanical performance of different socket structures is evaluated under various representative task scenarios, with peak normal force, mean normal force, and force distribution variance adopted as the key comfort evaluation indices. The results demonstrate that the proposed active multi-unit socket, particularly the double-layered eight-unit symmetric radial staggered configuration, enables a robust balance between comfort and stability across diverse task scenarios, thereby establishing an effective and scalable design paradigm for long-term adaptive upper-limb prosthetic sockets.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies · Soft Robotics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150008, China
Beijing Institute of Space Launch Technology, Beijing 100076, China
Funding
National Natural Science Foundation of China · National Natural Science Foundation of China under the Basic Science Center Program for “Space Robot Intelligent Manipulation” · State Key Laboratory of Robotics and Systems
References (34)
Show source-provided references
1. Multidimensional Treatment of Periprosthetic Joint Infection Using Fusion Peptide-Grafted Chitosan Coated Porous Tantalum Scaffold
2. Toward Higher-Performance Bionic Limbs for Wider Clinical Use10.1038/s41551-021-00732-x ↗
3. Osseointegration for Amputees: Current Implants, Techniques, and Future Directions10.2106/JBJS.RVW.19.00043 ↗
4. Femoral Fracture Risk in Transfemoral Amputees with Bone-Anchored Prosthetic Limbs during Activities of Daily Living10.1186/s13018-025-06311-z ↗
5. Preliminary Characterization of Rectification for Transradial Prosthetic Sockets10.1038/s41598-024-56333-6 ↗
6. Advances in the Measurement of Prosthetic Socket Interface Mechanics: A Review of Technology, Techniques, and a 20-Year Update10.1080/17434440.2023.2244418 ↗
7. Soft Transfemoral Prosthetic Socket With Sensing and Augmenting Feedback: A Case Study10.1109/TMRB.2024.3381378 ↗
8. An Adaptive Prosthetic Socket for People with Transtibial Amputation10.1038/s41598-024-61234-9 ↗
9. The Northwestern University Supracondylar Suspension Technique for Below-Elbow Amputations
10. Cordella, F., Ciancio, A.L., Sacchetti, R., Davalli, A., Cutti, A.G., Guglielmelli, E., and Zollo, L. (2016). Literature Review on Needs of Upper Limb Prosthesis Users. Front. Neurosci., 10.10.3389/fnins.2016.00209 ↗
11. Design of Lower Limb Prosthetic Sockets: A Review10.1080/17434440.2022.2020094 ↗
12. Biomechanical Design Considerations for Transradial Prosthetic Interface: A Review10.1177/0954411915624452 ↗
13. The Evolution of Upper Limb Prosthetic Socket Design10.1097/JPO.0b013e31817d2f08 ↗
14. A 3-Quarter Type Below-Elbow Socket for Myoelectric Prostheses10.3109/03093648609164504 ↗
15. A High-Performance, Variable-Suspension, Transradial (Below-Elbow) Prosthesis10.1097/00008526-199500720-00007 ↗
16. Design of a Novel Prosthetic Socket: Assessment of the Thermal Performance10.1016/j.jbiomech.2015.02.048 ↗
17. Systematic Review of Effects of Current Transtibial Prosthetic Socket Designs-Part 1: Qualitative Outcomes10.1682/JRRD.2014.08.0183 ↗
18. Sockets for Limb Prostheses: A Review of Existing Technologies and Open Challenges10.1109/TBME.2017.2775100 ↗
19. Dynamically Adaptive Soft Metamaterial for Wearable Human–Machine Interfaces10.1038/s41467-025-57634-8 ↗
20. Polizzotto, M.G., Zaidi, A.Z., Paternò, L., and Menciassi, A. (2024, January 1–4). Self-Adaptive Upper Limb Prosthetic Socket. Proceedings of the 2024 10th IEEE RAS/EMBS International Conference for Biomedical Robotics and Biomechatronics (BioRob), Heidelberg, Germany.10.1109/BioRob60516.2024.10719804 ↗
21. A Pneumatic Reconfigurable Socket for Transtibial Amputees10.1002/cnm.3801 ↗
22. Automatic Control of Prosthetic Socket Size for People WithTranstibial Amputation: Implementation and Evaluation10.1109/TBME.2020.2992739 ↗
23. Toward the Development of User-Centered Neurointegrated Lower Limb Prostheses10.1109/RBME.2023.3309328 ↗
24. Ibrahim, M.T., Hashim, N.A., Abd Razak, N.A., Abu Osman, N.A., Gholizadeh, H., and Astuti, S.D. (2024). Techniques for Measuring the Fluctuation of Residual Lower Limb Volume in Clinical Practices: A Systematic Review of the Past Four Decades. Appl. Sci., 14.10.3390/app14062594 ↗
25. Residual Limb Fluid Volume Change and Volume Accommodation: Relationships to Activity and Self-Report Outcomes in People with Trans-Tibial Amputation10.1177/0309364617752983 ↗
26. Schofield, J.S., Schoepp, K.R., Williams, H.E., Carey, J.P., Marasco, P.D., and Hebert, J.S. (2017). Characterization of Interfacial Socket Pressure in Transhumeral Prostheses: A Case Series. PLoS ONE, 12.10.1371/journal.pone.0178517 ↗
27. Effect of Prosthetic Socks on the Frictional Properties of Residual Limb Skin10.1016/j.wear.2011.05.032 ↗
28. In Vivo Friction Properties of Human Skin10.3109/03093649909071625 ↗
29. Real-Time Force Optimization Algorithm for Multi-Finger Grasping10.3901/JME.2007.12.144 ↗
30. Comparison of Ischial Containment and Subischial Sockets Effect on Gait Biomechanics in People with Transfemoral Amputation: A Randomized Crossover Trial10.1016/j.apmr.2022.02.013 ↗
31. Dextrous Hand Grasping Force Optimization10.1109/70.499823 ↗
32. Yao, S., Luan, Y., Ceccarelli, M., and Carbone, G. (2023). Optimization Method of the Clamping Force for Large Cabin Parts. Appl. Sci., 13.10.21203/rs.3.rs-2913930/v1 ↗
33. Perception of Surface Pressure Applied to the Hand10.1080/001401399184947 ↗
34. Analyzing Soft Tissue Stiffness of Human Upper Arms during Physical Dynamic and Quasi-Static Impacts in Human–Machine Interaction10.1002/hfm.20983 ↗