Fatigue Life of Cast Titanium Alloys Under Simulated Denture Framework Displacements
Source abstract
Abstract
The objective of the study was to evaluate the hypothesis that the mechanical properties and fatigue behavior of removable partial dentures (RPD) made from cast titanium alloys can be improved by alloying with low-cost, low-melting elements such as Cu, Al, and Fe using commercially pure Ti (CP-Ti) and Ti-6Al-4V as controls. RPD specimens in the form of rest-shaped, clasp, rectangular-shaped specimens and round-bar tensile specimens were cast using an experimental Ti-5Al-5Cu alloy, Ti-5Al-1Fe, and Ti-1Fe in an Al2O3-based investment with a centrifugal-casting machine. The mechanical properties of the alloys were determined by performing tensile tests under a controlled displacement rate. The fatigue life of the RPD specimens was tested by the three-point bending in an MTS testing machine under a cyclic displacement of 0.5 mm. Fatigue tests were performed at 10 Hz at ambient temperature until the specimens failed into two pieces. The tensile data were statistically analyzed using one-way ANOVA (α = 0.05) and the fatigue life data were analyzed using the Kaplan-Meier survival analysis (α = 0.05). The experimental Ti-5Al-5Cu alloy showed a significantly higher average fatigue life than that of either CP-Ti or Ti-5Al-1Fe alloy (p < 0.05). SEM fractography showed that the fatigue cracks initiated from surface grains, surface pores, or hard particles in surface grains instead of the internal casting pores. Among the alloys tested, the Ti-5Al-5Cu alloy exhibited favorable results in fabricating dental appliances with an excellent fatigue behavior compared with other commercial alloys.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Dental materials and restorations · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. G.W. Thompson and P.S. Kreisel: J. Prosthet. Dent., 1998, vol. 79, pp. 56–59.10.1016/S0022-3913(98)70194-5 ↗
2. M. Niinomi: Recent Biocompatible Metallic Materials. Structural Biomaterials for the 21st Century, M. Niinomi, T. Okabe, et al., eds., TMS, Warrendale, PA, 2001, pp. 3–14.
3. M. Könönen, J. Rintanen, A. Waltimo, and P. Kempainen: J. Prosthet. Dent., 1995, vol. 73, pp. 4–7.10.1016/S0022-3913(05)80264-1 ↗
4. M. Koike: J. Jpn. Prosthodont. Soc., 2005, vol. 49, pp. 498–501 (in Japanese).
5. M. Kotake: J. Jpn. Prosthodont. Soc., 2007, vol. 51, pp. 604–07 (in Japanese).
6. T. Okabe and H. Herø: Cells Mater., 1995, vol. 5, pp. 211–30.
7. S.G. Steinemann: Evaluation of Biomaterials, Wiley, New York, 1980, pp. 1–34.
8. H. Shimizu, T. Habu, Y. Takada, K. Watanabe, O. Okuno, and T. Okabe: Biomaterials, 2002, vol. 23, pp. 2275–81.10.1016/S0142-9612(01)00357-X ↗
9. M. Koike, P.E. Lockwood, J.C. Wataha, H. Fujii, and T. Okabe: J. Biomed. Mater. Res., 2007, vol. 83B, pp. 327–31.10.1002/jbm.b.30799 ↗
10. M. Koike, K.S. Chan, and T. Okabe: in Innovation in Titanium Technology, M.H. Gungor, M.A. Imam, and F.H. Froes, eds., TMS, Warrendale, PA, 2007, pp. 199–208.
11. M. Koike, A. Krysiak, K.S. Chan, L. Guo, and T. Okabe: J. Mater. Proc. Technol., 2011, vol. 211, pp. 560–65.10.1016/j.jmatprotec.2010.10.022 ↗
12. M. Koike, M. Ito, O. Okuno, K. Kimura, O. Takeda, T.H. Okabe, and T. Okabe: J. Mater. Eng. Perform., 2005, vol. 14, pp. 778–83.10.1361/105994905X75600 ↗
13. C. Leyens and M. Peters: Titanium and Titanium Alloys: Fundamentals and Applications, Wiley VCH GmbH & Co KGaA, Weinheim, Germany, 2003.10.1002/3527602119 ↗
14. M. Koike, C. Ohkubo, H. Sato, H. Fujii, and T. Okabe: Mater. Sci. Eng. C, 2005, vol. 25, pp. 349–56.10.1016/j.msec.2005.04.002 ↗
15. R.G. Craig and J.M. Power: Restorative Dental Materials, 11th ed., Mosby, St. Louis, MO, 2002.
16. J.M. Powers and R.I. Sakaguchi: Craig’s Restorative Dental Materials, 13th ed., Elsevier/Mosby, Philadelphia, PA, 2012.
17. J.T. Bridgeman, V.A. Marker, S.K. Hummel, B.W. Benson, and L.L. Pace: J. Prosthet. Dent., 1997, vol. 78, pp. 187–93.10.1016/S0022-3913(97)70124-0 ↗
18. A.H.B.M. Vermeulen, H.M.A.M. Keltjens, M.A. Van’t Hof, and A.F. Kayser: J. Prosthet. Dent., 1996, vol. 76, pp. 267–72.10.1016/S0022-3913(96)90170-5 ↗
19. Y. Hochberg and A.C. Tamhane: Multiple Comparison Procedures, John Wiley & Sons, New York, NY, 1987.10.1002/9780470316672 ↗
20. E.L. Kaplan and P. Meier: J. Am. Stat. Assoc., 1958, vol. 53, pp. 457–81.10.1080/01621459.1958.10501452 ↗
21. S.Y. Sung and Y.-J. Kim: Mater. Sci. Eng. A, 2005, vol. 405, pp. 173–77.10.1016/j.msea.2005.05.092 ↗
22. K.S. Chan, M. Koike, B.W. Johnson, and T. Okabe: Metall. Mater. Trans. A, 2008, vol. 39A, pp. 171–80.10.1007/s11661-007-9406-0 ↗
23. M. Koike and T. Okabe: Proceedings of the Materials & Processes for Medical Devices Conference 2007. ASM International, Materials Park, OH, 2008, pp. 109–13.
24. D.J. Jones and L.T. Garcia: Removable Partial Dentures: A Clinician’s Guide, John Wiley & Sons, Inc., Hoboken, NY, 2009.
25. ASTM B367-09, Standard Specification for Titanium and Titanium Alloy Castings, ASTM International, 2009, West Conshohocken, PA.
26. E.S. Bumps, H.D. Kessler, and M. Hansen: Trans. ASM, 1953, vol. 45, pp. 1008–28.
27. H.R. Ogden and R.I. Jaffee: “The Effects of Carbon, Oxygen, and Nitrogen on the Mechanical Properties of Titanium and Titanium Alloys,” TML Report No. 20, Titanium Metallurgical Laboratory, Battelle Memorial Institute, Columbus, OH, October 19, 1955.10.2172/4370612 ↗
28. W.P. Roe, H.R. Palmer, and W.R. Opie: Trans. ASM, 1960, vol. 52, pp. 191–200.
29. W.J. Boettinger, M.E. Williams, S.R. Coriell, U.R. Kattner, and B.A. Mueller, Metall. Mater. Trans. B, 2000, vol. 31B, pp. 1419–27.10.1007/s11663-000-0026-y ↗
30. R.C. Atwood, P.D. Lee, and R.V. Curtis: Dent. Mater., 2005, vol. 21, pp. 178–86.10.1016/j.dental.2004.02.010 ↗