Reduced fibrous capsule elastic fibers from biologic ECM-enveloped CIEDs in minipigs, supported with a novel compression mechanics model
Source abstract
Abstract
BACKGROUND: Fibrous capsules (Fb) in response to cardiovascular implantable electronic devices (CIEDs), including a pacemaker (P) system, can produce patient discomfort and difficulties in revision surgery due partially to their increased compressive strength, previously linked to elevated tissue fibers. OBJECTIVE: A preliminary study to quantify structural proteins, determine if biologic extracellular matrix-enveloped CIEDs (PECM) caused differential Fb properties, and to implement a realistic mechanical model. METHODS: Retrieved Fb (-P and -PECM) from minipigs were subjected to biomechanical (shear oscillation and uniaxial compression) and histological (collagen I and elastin) analyses. RESULTS: Fb-PECM showed significant decreases compared to Fb-P in: low strain-loss modulus (390 vs. 541 Pa) across angular frequencies, high strain-compressive elastic modulus (1043 vs. 2042 kPa), and elastic fiber content (1.92 vs. 3.15 μg/mg tissue). Decreases in elastin were particularly noted closer to the implant’s surface (Fb-PECM = 71% vs. Fb-P = 143% relative to dermal elastin at mid-tangential sections) and verified with a solid mechanics hyperelasticity with direction-dependent fiber viscoelasticity compression simulation (r2 ≥ 98.9%). CONCLUSIONS: The biologic envelope composed of decellularized porcine small intestine submucosa ECM for CIEDs promoted fibrous tissues with less elastic fibers. Novel compression modeling analyses directly correlated this singular reduction to more desirable subcutaneous tissue mechanics.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Tissue Engineering and Regenerative Medicine · Elasticity and Material Modeling · Bariatric Surgery and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
, Hofstra University, , , USA
Aziyo Biologics, Inc., , , USA
References (56)
Show source-provided references
1. The pathology of the foreign body reaction against biomaterials10.1002/jbm.a.35958 ↗
2. Foreign body response to subcutaneous implants in diabetic rats10.1371/journal.pone.0110945 ↗
3. Key players in the immune response to biomaterial scaffolds for regenerative medicine10.1016/j.addr.2017.07.006 ↗
4. Domesticating the foreign body response: Recent advances and applications10.1016/j.addr.2019.08.010 ↗
5. Cardiac implantable electronic device therapy: Permanent pacemakers, implantable cardioverter defibrillators, and cardiac resynchronization devices10.1016/j.mcna.2019.04.005 ↗
6. Antifibrotic strategies for medical devices10.1016/j.addr.2020.06.008 ↗
7. Biomaterials-based modulation of the immune system10.1155/2013/732182 ↗
8. Effect of tissue microenvironment on fibrous capsule formation to biomaterial-coated implants10.1016/j.biomaterials.2021.120806 ↗
9. Wagner · 2020
10. Type I collagen-based fibrous capsule enhances integration of tissue-engineered cartilage with native articular cartilage10.1007/s10439-013-0958-4 ↗
11. Collagen organization in an oriented fibrous capsule10.1016/0141-8130(94)90007-8 ↗
12. Quantitative characterization of collagen in the fibrotic capsule surrounding implanted polymeric microparticles through second harmonic generation imaging10.1371/journal.pone.0130386 ↗
13. Non-linear optical microscopy and histological analysis of collagen, elastin and lysyl oxidase expression in breast capsular contracture10.1186/s40001-018-0322-0 ↗
14. Tissue reaction induced by implanted venous access ports in adult patients after infection of the implantation site10.3233/CH-141881 ↗
15. Elastin architecture10.1016/j.matbio.2019.07.005 ↗
16. Elastin10.1016/S0065-3233(05)70013-9 ↗
17. Clinical relevance of elastin in the structure and function of skin10.1093/asjof/ojab019 ↗
18. A rare entity-percutaneous lead extraction in a very late onset pacemaker endocarditis: Case report and review of literature10.3390/diagnostics11010096 ↗
19. Microengineered biosynthesized cellulose as anti-fibrotic in vivo protection for cardiac implantable electronic devices10.1016/j.biomaterials.2019.119583 ↗
20. Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads10.1002/jbm.10306 ↗
21. A technique for the prevention of automatic implantable cardioverter defibrillator generator migration10.1111/j.1540-8159.1990.tb02132.x ↗
22. HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction10.1016/j.hrthm.2017.09.001 ↗
23. Recurrent implantable cardioverter-defibrillator replacement is associated with an increasing risk of pocket-related complications
24. Generator pocket adhesions of cardiac leads: Classification and correlation with transvenous lead extraction results10.1111/pace.12184 ↗
25. Device pocket scar predicts transvenous lead extraction difficulty10.19102/icrm.2015.061101 ↗
26. Neointimal fibrotic lead encapsulation - Clinical challenges and demands for implantable cardiac electronic devices10.1016/j.jjcc.2017.01.011 ↗
27. Characterization of the capsule surrounding smooth and textured tissue expanders and correlation with contracture10.1097/GOX.0000000000001403 ↗
28. Antibiotic-eluting envelopes to prevent cardiac-implantable electronic device infection: Past, present, and future
29. Patient profiles in the utilization of the CanGaroo(R) envelope
30. Vascular endothelial growth factor in porcine-derived extracellular matrix10.3109/10623320109063154 ↗
31. Extracellular matrix as an inductive scaffold for functional tissue reconstruction10.1016/j.trsl.2013.11.003 ↗
32. Decellularized allogeneic and xenogeneic tissue as a bioscaffold for regenerative medicine: Factors that influence the host response10.1007/s10439-013-0963-7 ↗
33. ECM-based materials in cardiovascular applications: Inherent healing potential and augmentation of native regenerative processes10.3390/ijms10104375 ↗
34. Identification of extractable growth factors from small intestinal submucosa10.1002/(SICI)1097-4644(19971215)67:4<478::AID-JCB6>3.0.CO;2-P ↗
35. Replicates and repeats10.1186/s12915-016-0254-5 ↗
36. Compressive strengths of PEG gels with glycerol and bioglass particles10.1557/jmr.2019.45 ↗
37. Chapra · 2018
38. Elastin purification and solubilization10.1016/bs.mcb.2017.08.012 ↗
39. Mechanical and biological properties of keratose biomaterials10.1016/j.biomaterials.2011.07.054 ↗
40. The elastin network: Its relationship with collagen and cells in articular cartilage as visualized by multiphoton microscopy10.1111/j.1469-7580.2009.01149.x ↗
41. Changes in elastin, elastin binding protein and versican in alveoli in chronic obstructive pulmonary disease10.1186/1465-9921-9-41 ↗
42. A comparison of human and porcine skin in laser-assisted drug delivery of chemotherapeutics10.1002/lsm.23344 ↗
43. Isotropic incompressible hyperelastic models for modelling the mechanical behaviour of biological tissues: A review10.1515/bmt-2014-0146 ↗
44. A story of fibers and stress: Matrix-embedded signals for fibroblast activation in the skin10.1111/wrr.12950 ↗
45. CARD29: An Acellular Biologic Extracellular Matrix (ECM) envelope for cardiovascular implantable electronic devices: preclinical evaluation10.1097/01.mat.0000841052.84245.36 ↗
46. Fibrous capsule formation after subcutaneous implanation of synthetic materials in experimental animals10.1097/00006534-197408000-00010 ↗
47. Transmural variation in elastin fiber orientation distribution in the arterial wall10.1016/j.jmbbm.2017.08.002 ↗
48. The mechanical properties of human adipose tissues and their relationships to the structure and composition of the extracellular matrix10.1152/ajpendo.00111.2013 ↗
49. End-stage renal disease predicts complications in pacemaker and ICD implants10.1111/j.1540-8167.2011.02066.x ↗
50. Risk factors influencing complications of cardiac implantable electronic device implantation: Infection, pneumothorax and heart perforation: a nationwide population-based cohort study10.1097/MD.0000000000000213 ↗
51. Incidence and predictors of perioperative complications with transvenous lead extractions: Real-world experience with national cardiovascular data registry10.1161/CIRCEP.116.004768 ↗
52. Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: Results from the REPLACE registry10.1161/CIRCULATIONAHA.110.976076 ↗
53. Mechanical properties of arterial elastin with water loss10.1115/1.4038887 ↗
54. Aging in skin of color: Disruption to elastic fiber organization is detrimental to skin’s biomechanical function10.1016/j.jid.2018.10.026 ↗
55. Elastic fiber pattern in regressing melanoma: A histochemical and immunohistochemical study10.1111/j.1600-0560.2010.01531.x ↗
56. Elastic fiber pattern in scleroderma/morphea10.1111/j.1600-0560.2009.01201.x ↗