journal article·2016-08-12

Compound Doppler ultrasound signal simulation for pulsatile carotid arteries with a stenosis

Lian Gao, Yufeng Zhang, Yi Zhou, Xiao Hu, Li Deng, Kexin Zhang, Guanghui Cai, Junhua Zhang

Publisher page

Abstract

BACKGROUND: The simulated Doppler blood flow signals are widely used to assess the performance of the clutter filters for removing wall components while reserving low-velocity signals scattered from physiological blood flow approaching the inner vessel-wall injured by a stenosed lesion. OBJECTIVE: By simultaneously taking into account the natural attributes of the Doppler equipment, blood flow as well as vessel wall of pulsatile carotid arteries with a stenosis, a computer simulation method is presented to produce the compound Doppler ultrasound blood flow signals. METHODS: The in-phase and quadrature (I/Q) axial as well as radial blood flow signals are simulated by superposing a series of cosine functions regulated by the spectrograms estimated from the axial and radial velocity profiles firstly obtained through the solution of the incompressible Navier-Stokes equations, respectively. Meanwhile, the I/Q Doppler signals echoed from pulsatile near (anterior) and far (posterior) walls are reproduced based on their radial movements during a cardiac cycle. Ultimately, those confirmed quadrature signals are summed to generate the compound Doppler signals including the contribution from both blood flow and stenosed vessel-wall. RESULTS: The compound Doppler ultrasound signals echoed from both axial and radial blood flows as well as vessel walls with obstruction grades of 0% (normal arteries), 10% and 25% are simulated respectively. The real signals from the left carotid artery with an approximately 10% stenosis degree are also collected for further assessing the believability of simulated versions. CONCLUSIONS: The simulated and clinical tests demonstrate that the proposed computer simulation method can produce compound Doppler signals with confirmed qualitative and quantitative characteristics resembled with the clinical versions, which could be used as an theoretical data source for evaluating the performance of the signal separation between pulsatile blood flows and vessel walls with mild stenosed-lesions.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Ultrasound Imaging and Elastography · Cerebrovascular and Carotid Artery Diseases · Coronary Interventions and Diagnostics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electronic Engineering, Information School, Yunnan University, Kunming, Yunnan 650091, China. E-mails: 962245641@qq.com, yfengzhang@yahoo.com, 3002380@qq.com, 1162019872@qq.com, 617674101@qq.com, ghcai@ynu.edu.cn, jhzhang@ynu.edu.cn

Cardiovascular Department, The Second Affiliated Hospital of Kunming Medical College, Kunming, Yunnan 650031, China. E-mail: zhangkexingkm@vip.sina.com

References (30)

Show source-provided references
1. Parameters describing motion in carotid artery plaques from ultrasound examination: A reproducibility study10.1016/j.ultrasmedbio.2004.07.002 ↗
2. The effect of aortic wall and aortic leaflet stiffening on coronary hemodynamic: A fluid-structure interaction study10.1007/s11517-013-1066-1 ↗
3. Noninvasive evaluation of arotid artery stenosis: Indications, strategies, and accuracy10.1016/j.nic.2005.06.005 ↗
4. Viscoelastic deterioration of the carotid artery vascular wall is a possible predictor of coronary artery disease10.5551/jat.24513 ↗
5. The analysis and diagnosis of unstable behavior of the blood vessel wall with an aneurysm based on noise science10.5551/jat.13.163 ↗
6. D.H. Evans and W.N. McDicken, Doppler Ultrasound: Physics, Instrumentation and Signal Processing, Wiley, Chichester, 2000.
7. J.W. Hallett, J.L. Mills, J.J. Earnshaw, J.A. Reekers and T.W. Rooke, Comprehensive Vascular and Endovascular Surgery, Mosby/Elsevier, USA, 2009.
8. A novel ultrasound instrument for investigation of arterial mechanics10.1016/j.ultras.2003.11.008 ↗
9. Clinical validation of common carotid artery wall distension assessment based on multigate Doppler processing10.1016/j.ultrasmedbio.2005.04.001 ↗
10. Flow rate defective boundary conditions in haemodynamics simulations10.1002/fld.843 ↗
11. Ultrasonic observation of blood disturbance in a stenosed tube: Effects of flow acceleration and turbulence downstream10.1016/j.ultrasmedbio.2007.07.009 ↗
12. Computational analysis of nanoparticle adhesion to endothelium: Effects of kinetic rate constants and wall shear rates10.1007/s11517-011-0735-1 ↗
13. Flow in locally constricted tubes at low Reynolds numbers10.1115/1.3408496 ↗
14. Eigen-based clutter filter design for ultrasound color flow imaging: A review10.1109/TUFFC.2010.1521 ↗
15. D.K.H. Cheung, H.C.T. Chiu, L. Zhang, C. Hu, K.K. Shung and A.C.H. Yu, Adaptive clutter filter design for micro-ultrasound color flow imaging of small blood vessels, in: IEEE Ultrasonics Symposium, 2010, pp. 1206–1209.10.1109/ULTSYM.2010.5935686 ↗
16. Single-ensemble-based eigen-processing methods for color flow imaging – Part I. The Hankel-SVD filter10.1109/TUFFC.2008.682 ↗
17. A single-ensemble clutter rejection method based on the analytic geometry for ultrasound color flow imaging10.1016/j.ultrasmedbio.2011.07.005 ↗
18. A clutter removal method for the Doppler ultrasound signal based on a nonlinear diffusion equation10.1088/0957-0233/19/5/055101 ↗
19. Assessment of arterial distension based on continuous wave Doppler ultrasound with an improved Hilbert–Huang processing10.1109/TUFFC.2010.1399 ↗
20. The removal of wall components in Doppler ultrasound signals by using the empirical mode decomposition algorithm10.1109/TBME.2007.891936 ↗
21. Simulating Doppler ultrasound blood flow signals with the pulsation of the vascular wall
22. Time-scale removal of “wall thump” in Doppler ultrasound signals: A simulation study10.1109/TUFFC.2004.1334852 ↗
23. The wall signal removal in Doppler ultrasound systems based on recursive PCA10.1016/j.ultrasmedbio.2003.11.014 ↗
24. Doppler ultrasound signal denoising based on wavelet frames10.1109/58.920698 ↗
25. P.J. Fish, C.A.C. Bastos and F. Vaz, Blood and wall signal simulator for Doppler ultrasound signal analysis algorithm development, in: Proc. 23rd Annual EMBS International Conference, Vol. 1, Istanbul, Turkey, 2001, pp. 135–138.10.1109/IEMBS.2001.1018869 ↗
26. A computer simulation model for Doppler ultrasound signals from pulsatile blood flow in stenosed vessels10.1016/j.compbiomed.2012.07.002 ↗
27. Y. Zhang, L. Gao, K. Shen, K. Zhang, J. Yan, W. Cheng and J. Zhang, A simulator for mixed Doppler ultrasound signals from pulsatile blood flow and vessel wall with mild stenosis, in: Proc. 35rd Annual International Conference of the IEEE EMBS, Osaka, Japan, 2013, pp. 1903–1906.10.1109/EMBC.2013.6609897 ↗
28. Bian · 2000 · 1
29. “Speckle” in continuous wave Doppler ultrasound spectra: A simulation study10.1109/T-UFFC.1986.26891 ↗
30. Field: A program for simulating ultrasound systems