journal article·2016-09-28

Interfragmentary motion assessment for three different fixation techniques of femoral neck fractures in young adults

Shabnam Samsami, Sadegh Saberi, Nima Bagheri, Gholamreza Rouhi

Publisher page

Abstract

BACKGROUND: Vertical femoral neck fractures in the youth could be happened in high-energy accidents, and because of dominant shearing forces, this fracture is considered as a troublesome injury with a controversy regarding selection of the best fixation method. OBJECTIVE: The long term goal of this quasi-experimental study was to find the more stable fixation method among cannulated screws (CSs), proximal femoral locking plate (PFLP), and dynamic hip screw with derotational screw (DHS+DS) for this kind of fracture. METHODS: Twelve fresh-frozen cadaveric femurs were assigned to three groups that were matched for mean bone mineral density and stiffness of intact bone. Vertical fractures were artificially mimicked in the specimens and fixed using three different implants, i.e. CSs, PFLP, and DHS+DS. Then, the samples were tested under incremental, cyclic, and failure loading phases. RESULTS: The differences in all biomechanical parameters were statistically significant among tested groups (p<0.05). All biomechanical parameters for the DHS+DS method of fixation are significantly different from those corresponding to CSs (p<0.05). There were no significant differences in failure load and failure energy between the PFLP and CSs techniques (p>0.05). Also, there were no significant differences in relative stiffness and femoral head displacement between the PFLP and DHS+DS groups (p>0.05). CONCLUSIONS: Based on the clinical assumption that restricted weight-bearing regimen is recommended in the postoperative rehabilitation protocol, the results of this study suggest that the priority order of selection for the stable fixation implant of vertical femoral neck fracture in young patients is DHS+DS, then PFLP, and finally CSs.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Hip and Femur Fractures · Orthopaedic implants and arthroplasty · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran 15875-4413, Iran. E-mails: samsami_shabnam@yahoo.com, grouhi@uottawa.ca, grouhi@aut.ac.ir

Department of Orthopaedy, Tehran University of Medical Sciences, Tehran, 14155-6447, Iran. E-mails: sadeghsaberi@yahoo.com, nimab1360@gmail.com

References (21)

Show source-provided references
1. Results of internal fixation of Pauwels type-3 vertical femoral neck fractures10.2106/JBJS.G.01353 ↗
2. Using biomechanics to improve the surgical technique for internal fixation of intracapsular femoral neck fractures10.1142/S0192415X09006801 ↗
3. The management of intracapsular fracture of the femoral neck10.1016/j.mporth.2009.11.001 ↗
4. Operative treatment of femoral neck fractures in patients between the ages of fifteen and fifty years10.2106/00004623-200408000-00015 ↗
5. Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone10.1016/j.clinbiomech.2013.08.007 ↗
6. Vertical shear fractures of the femoral neck: A biomechanical study
7. Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques10.1097/BOT.0b013e31814b822e ↗
8. The effect of moment arm length on high angled femoral neck fractures (Pauwels’ III)10.4236/jbise.2010.35062 ↗
9. Biomechanical analysis of a novel femoral neck locking plate for treatment of vertical shear Pauwel’s type C femoral neck fractures10.1016/j.injury.2011.09.012 ↗
10. Comparison of three fixation methods for femoral neck fracture in young adults: Experimental and numerical investigations10.1007/s40846-015-0085-9 ↗
11. Analysis of fracture gap change: Dynamic and static stability of different stability of different osteosynthetic procedures in the femoral neck10.1016/S0020-1383(02)00328-5 ↗
12. The effect of the degree of screw tension on interfragmentary displacement in stabilized fractures of the femoral neck10.1097/BCO.0b013e3181972894 ↗
13. Comparison of two tools for the measurement of interfragmentary movement in femoral neck fractures stabilised by cannulated screws10.1016/j.rcim.2010.06.014 ↗
14. Laboratory evaluation of hip fracture fixation devices
15. Biomechanical evaluation of a new device for internal fixation of femoral neck fractures10.3109/10731199.2010.538404 ↗
16. Postoperative weight-bearing after a fracture of the femoral neck or an intertrochanteric fracture10.2106/00004623-199803000-00007 ↗
17. Hip contact forces and gait patterns from routine activities10.1016/S0021-9290(01)00040-9 ↗
18. Treatment of femoral neck fractures in young adults
19. A biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model10.1097/TA.0b013e3181efb1d1 ↗
20. A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: The intertan versus cannulated screws or a dynamic hip screw
21. Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: A biomechanical study10.1016/S0020-1383(03)00059-7 ↗