journal article·2016-05-20

Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery

Remel Alingalan Salmingo, Shigeru Tadano, Yuichiro Abe, Manabu Ito

Publisher page

Abstract

Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Scoliosis diagnosis and treatment · Spinal Fractures and Fixation Techniques · Spine and Intervertebral Disc Pathology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Biomedical Engineering, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads B349, Kongens Lyngby, Denmark 2800

JJ X-Ray A/S, DTU Scion, Science and Technology Park, Technical University of Denmark, Diplomvej B377, Kongens Lyngby, Denmark 2800

Laboratory of Biomechanical Design, Division of Human Mechanical Systems and Design, Faculty of Engineering, Hokkaido University, North 13 West 8 North Ward, Sapporo, Japan 060-8628

Department of Orthopaedic Surgery, Eniwa Hospital, Kogane-cho 2-1-1, Sapporo, Japan 061-1449

Advanced Medicine for Spine and Spinal Cord Disorders, Graduate School of Medicine, Hokkaido University, North 15 West 7 North Ward, Sapporo, Japan 060-8638

References (29)

Show source-provided references
1. Variability of spinal instrumentation configurations in adolescent idiopathic scoliosis10.1007/s00586-006-0063-6 ↗
2. Intra and interobserver variability of preoperative planning for surgical instrumentation in adolescent idiopathic scoliosis10.1007/s00586-007-0431-x ↗
3. Biomechanical basis of optimal scoliosis surgical correction10.1016/0021-9290(88)90001-2 ↗
4. Optimization of skeletal configuration: Studies of scoliosis correction biomechanics10.1016/0021-9290(91)90336-L ↗
5. Intra-operative tracking of the trunk during surgical correction of scoliosis: A feasibility study10.3109/10929080009149851 ↗
6. L. Duong, J. Mac-Thiong and H. Labelle, Real time noninvasive assessment of external trunk geometry during surgical correction of adolescent idiopathic scoliosis, Scoliosis 4 (2009), 5.10.1186/1748-7161-4-5 ↗
7. Intraoperative comparison of two instrumentation techniques for the correction of adolescent idiopathic scoliosis. Rod rotation and translation10.1097/00007632-199910010-00009 ↗
8. Image-guided spinal surgery10.1002/rcs.69 ↗
9. Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging10.1080/10790268.2008.11753648 ↗
10. Minimum 10 years follow-up surgical results of adolescent idiopathic scoliosis patients treated with TSRH instrumentation10.1007/s00586-006-0147-3 ↗
11. Coronal and sagittal plane correction in adolescent idiopathic scoliosis: A comparison between all pedicle screw versus hybrid thoracic hook lumbar screw constructs10.1097/01.brs.0000255030.78293.fd ↗
12. Restoration of thoracic kyphosis by posterior instrumentation in adolescent idiopathic scoliosis: Comparative radiographic analysis of two methods of reduction10.1097/BRS.0b013e31817886be ↗
13. Simultaneous double rod rotation technique in posterior instrumentation surgery for correction of adolescent idiopathic scoliosis10.3171/2009.9.SPINE09377 ↗
14. Analysis of sagittal plane deformity and correction10.1097/BCO.0b013e3181e3dab3 ↗
15. Correction of main thoracic adolescent idiopathic scoliosis using pedicle screw instrumentation: Does higher implant density improve correction?10.1097/BRS.0b013e3181b4af34 ↗
16. Effect of direct vertebral body derotation on the sagittal profile in adolescent idiopathic scoliosis10.1007/s00586-011-1991-3 ↗
17. Influence of implant rodcurvature on sagittal correction of scoliosis deformity10.1016/j.spinee.2013.08.042 ↗
18. R. Salmingo, S. Tadano, K. Fujisaki, Y. Abe and M. Ito, A simple method for in vivo measurement of implant rod three-dimensional geometry during scoliosis surgery, ASME Journal of Biomechanical Engineering 134 (2012), 054502.10.1115/1.4006687 ↗
19. Sagittal spinopelvic balance in normal children and adolescents10.1007/s00586-005-0013-8 ↗
20. Morphometric analysis of the relationships between intervertebral disc and vertebral body heights: An anatomical and radiographic study of the human thoracic spine10.1111/j.1469-7580.2011.01397.x ↗
21. White · 1978 · 91
22. Axial rotation component of thoracic scoliosis10.1002/jor.1100070511 ↗
23. Pre-existent vertebral rotation in the human spine is influenced by body position10.1007/s00586-010-1400-3 ↗
24. Investigating the change in three dimensional deformity for idiopathic scoliosis using axially loaded MRI10.1016/j.clinbiomech.2011.12.004 ↗
25. Preoperative planning simulator for spinal deformity surgeries10.1097/BRS.0b013e31817bd89f ↗
26. Intraoperative three-dimensional correction during rod rotation technique10.1097/BRS.0b013e31819413ec ↗
27. Biomechanical modeling and analysis of a direct incremental segmental translation system for the instrumentation of scoliotic deformities10.1016/j.clinbiomech.2011.01.011 ↗
28. Corrective force analysis for scoliosis from implant rod deformation10.1016/j.clinbiomech.2012.01.004 ↗
29. Relationship of forces acting on implant rods and degree of scoliosis correction10.1016/j.clinbiomech.2012.12.001 ↗