A numerical study on the effect of geometrical parameters and loading profile on the expansion of stent
Source abstract
Abstract
BACKGROUND: Stenting has been proposed as an effective treatment to restore blood flow in obstructed arteries by plaques. Although several modified designs for stents have been suggested, most designs have the risk of disturbing blood flow. OBJECTIVE: The main objective is to propose a stent design to attain a uniform lumen section after stent deployment. METHODS: Mechanical response of five different designs of J & J Palmaz-Schatz stent with the presence of plaque and artery are investigated; four stents have variable strut thickness of different magnitudes and the rest one is a uniform-strut-thickness stent. Nonlinear finite element is employed to simulate the expansion procedure of the intended designs using ABAQUS explicit. RESULTS: The stent design whose first cell thickness linearly increases by 35 percent, exhibits the best performance, that is it has the lowest recoiling and stress induced in the intima for a given lumen gain. It also enjoys the minimal discrepancy between the final at the distal and proximal ends. CONCLUSIONS: A uniform widened artery can be achieved by using the stent design with 35 percent increase in its first cell, which provides the possibility to prevent from disturbing blood flow and consequently post-operation complications.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Coronary Interventions and Diagnostics · Peripheral Artery Disease Management · Elasticity and Material Modeling
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Biomechatronics and Cognitive Engineering Research Lab, School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran. E-mail: b_beigzadeh@iust.ac.ir
Fatigue and Fracture Research Lab, School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran. E-mail: s.alirezamir@hotmail.com
Fatigue and Fracture Research Lab, School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran. E-mail: m.ayat@iust.ac.ir
References (20)
Show source-provided references
1. A. Karimi, M. Navidbakhsh, A. Shojaei, K. Hassani and S. Faghihi, Study of plaque vulnerability in coronary artery using Mooney–Rivlin model: A combination of finite element and experimental method, Biomedical Engineering: Applications, Basis and Communications 26(01) (2014), 1450013.10.4015/S1016237214500136 ↗
2. Mechanical behavior of coronary stents investigated through the finite element method10.1016/S0021-9290(02)00033-7 ↗
3. Analysis of prolapse in cardiovascular stents: A constitutive equation for vascular tissue and finite-element modelling10.1115/1.1613674 ↗
4. Determination of the influence of stent strut thickness using the finite element method: Implications for vascular injury and in-stent restenosis10.1007/s11517-009-0432-5 ↗
5. Effects of varying slotted tube (stent) geometry on its expansion behaviour using finite element method10.1016/j.jmatprotec.2004.04.395 ↗
6. Changes in the mechanical environment of stenotic arteries during interaction with stents: Computational assessment of parametric stent designs10.1115/1.1835362 ↗
7. Influence of stent design on 1-year outcome after coronary stent placement: A randomized comparison of five stent types in 1,147 unselected patients10.1002/1522-726X(200007)50:3<290::AID-CCD5>3.0.CO;2-W ↗
8. Balloon-artery interactions during stent placement a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury10.1161/01.RES.84.4.378 ↗
9. A predictive study of the mechanical behaviour of coronary stents by computer modelling10.1016/j.medengphy.2004.08.012 ↗
10. Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method10.1016/j.jbiomech.2004.11.003 ↗
11. Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion10.1016/j.jmatprotec.2004.04.396 ↗
12. Stent expansion in curved vessel and their interactions: A finite element analysis10.1016/j.jbiomech.2006.11.009 ↗
13. Cardiovascular stent design and vessel stresses: A finite element analysis10.1016/j.jbiomech.2004.07.022 ↗
14. Finite-element analysis of a stenotic artery revascularization through a stent insertion10.1080/10255840108908007 ↗
15. 10.1115/1.402622910.1115/1.4026229 ↗
16. 10.1186/s40759-014-0002-x10.1186/s40759-014-0002-x ↗
17. Hemodynamics analyses of arterial expansions with implications to thrombosis and restenosis10.1016/S1350-4533(00)00006-0 ↗
18. 10.1063/1.489101910.1063/1.4891019 ↗
19. Hemodynamics analyses of arterial expansions with implications to thrombosis and restenosis10.1016/S1350-4533(00)00006-0 ↗
20. Elastic recoil of coronary stents: A comparative analysis10.1002/(SICI)1522-726X(200005)50:1<112::AID-CCD25>3.0.CO;2-X ↗