journal article·2024-01-04Open access

Analysis of transjugular intrahepatic portosystemic shunt by hemodynamic simulation

Junjie Cao, Zhichao Yao, Guijun Huo, Zhanao Liu, Yao Tang, Jian Huang, Minxin Chen, Rui Ding, Liming Shen, Dayong Zhou

Abstract

BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPS), which artificially creates a portocaval shunt to reduce portal venous pressure, has gradually become the primary treatment for portal hypertension (PH). However, there is no prefect shunting scheme in TIPS to balance the occurrence of postoperative complications and effective haemostasis. OBJECTIVE: To construct cirrhotic PH models and compare different shunting schemes in TIPS. METHODS: Three cases of cirrhotic PH with different liver volumes were selected for enhanced computed tomography scanning. The models for different shunting schemes were created using Mimics software, and following FLUENT calculation, all the models were imported into the software computational fluid dynamic-post for processing. In each shunting scheme, the differences in portal vein pressure, hepatic blood perfusion and blood flow from the superior mesenteric vein in the shunt tract were compared. The coefficient G was adapted to evaluate the advantages and disadvantages. RESULTS: (1) Concerning the precise location of the shunt tract, the wider the diameter of the shunt tract, the lower the pressure of the portal vein and the lesser the hepatic blood perfusion. Meanwhile, the pressure drop objective was not achieved with the 6 mm-diameter shunting scheme. (2) The 8 mm-diameter shunting scheme through the left portal vein (LPV) had the highest coefficient G. CONCLUSION: The 8 mm-diameter shunting scheme through the LPV may demonstrate a superior effect and prognosis in TIPS procedures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Liver Disease and Transplantation · Liver Disease Diagnosis and Treatment · Organ Transplantation Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

, Gusu School of Nanjing Medical University, , , , China

, Soochow University, , China

References (31)

Show source-provided references
1. Portal hypertension and related complications: Diagnosis and management10.1016/j.mayocp.2018.12.020 ↗
2. Study of liver cirrhosis over ten consecutive years in Southern China10.3748/wjg.v20.i37.13546 ↗
3. Predictors of in-hospital mortality among patients presenting with variceal gastrointestinal bleeding10.4103/1319-3767.151226 ↗
4. UK guidelines on the management of variceal haemorrhage in cirrhotic patients10.1136/gutjnl-2015-309262 ↗
5. Effectiveness of combined pharmacologic and ligation therapy in high-risk patients with acute esophageal variceal bleeding10.1038/ajg.2011.173 ↗
6. Regression of portal hypertension: Underlying mechanisms and therapeutic strategies10.1007/s12072-021-10135-4 ↗
7. Surgical portosystemic shunts versus transjugular intrahepatic portosystemic shunt for variceal haemorrhage in people with cirrhosis
8. Creation of an intrahepatic portosystemic shunt with a Grüntzig balloon catheter
9. Transjugular intrahepatic portosystemic stent-shunt in the management of portal hypertension10.1136/gutjnl-2019-320221 ↗
10. Microbiome therapeutics for hepatic encephalopathy10.1016/j.jhep.2021.08.004 ↗
11. Relationship between hemodynamic parameters and portal venous pressure in cirrhosis patients with portal hypertension10.1515/biol-2020-0101 ↗
12. Simulation of portal hemodynamic changes in a donor after right hepatectomy10.1115/1.4000957 ↗
13. Hemodynamic investigation of the liver using magnetic resonance imaging and computational fluid dynamics
14. Mechanotransduction and endothelial cell homeostasis: The wisdom of the cell10.1152/ajpheart.01047.2006 ↗
15. Hemodynamics in normal and diseased livers: Application of image-based computational models10.1007/s13239-014-0195-5 ↗
16. Hemodynamic analysis for transjugular intrahepatic portosystemic shunt (TIPS) in the liver based on a CT-image10.1109/TMI.2012.2219882 ↗
17. Comparative study of Newtonian and non-Newtonian simulations of drug transport in a model drug-eluting stent10.3233/BIR-2012-0607 ↗
18. Vascular corrosion casting: Analyzing wall shear stress in the portal vein and vascular abnormalities in portal hypertensive and cirrhotic rodents10.1038/labinvest.2010.138 ↗
19. Virtual hepatic venous pressure gradient with CT angiography (CHESS 1601): A prospective multicenter study for the noninvasive diagnosis of portal hypertension10.1148/radiol.2018180425 ↗
20. Prediction of overt hepatic encephalopathy after transjugular intrahepatic portosystemic shunt treatment: A cohort study10.1007/s12072-021-10188-5 ↗
21. Hepatic encephalopathy in chronic liver disease: 2014 practice guideline by AASLD and EASL10.1002/hep.27210 ↗
22. Percutaneous transhepatic intrahepatic portosystemic shunt for variceal bleeding: A series of six cases and literature review10.1016/j.jimed.2020.10.007 ↗
23. Hepatic encephalopathy: Etiology, pathogenesis, and clinical signs
24. Hyperammonemia in hepatic encephalopathy10.1016/j.jceh.2018.06.007 ↗
25. A model of blood-ammonia homeostasis based on a quantitative analysis of nitrogen metabolism in the multiple organs involved in the production, catabolism, and excretion of ammonia in humans10.2147/CEG.S160921 ↗
26. Smaller-diameter covered transjugular intrahepatic portosystemic shunt stents are associated with increased survival10.1016/j.cgh.2019.03.042 ↗
27. Transjugular intrahepatic portosystemic shunts in patients with cirrhosis with refractory ascites: Comparison of clinical outcomes by using 8-and 10-mm PTFE-covered stents10.1148/radiol.2017161644 ↗
28. Transjugular intrahepatic portosystemic shunt in cirrhosis: An exhaustive critical update10.3748/wjg.v26.i37.5561 ↗
29. How much reduction in portal pressure is necessary to prevent variceal rebleeding? A longitudinal study in 225 patients with transjugular intrahepatic portosystemic shunts10.1016/S0002-9270(01)03902-8 ↗
30. Transjugular intrahepatic portosystemic shunt using the new gore viatorr controlled expansion endoprosthesis: Prospective, single-center, preliminary experience10.1007/s00270-018-2040-y ↗
31. North American practice-based recommendations for transjugular intrahepatic portosystemic shunts in portal hypertension10.1016/j.cgh.2021.07.018 ↗