A review on pancreatic duct stents: materials and emerging trends
Source abstract
Abstract
Abstract Pancreatic duct strictures, which can arise from trauma, inflammation, or malignancy, often result in complications such as duct obstruction, pancreatic parenchymal hypertension, and ischemia. Endoscopic stenting is an effective therapeutic approach for managing these strictures. However, traditional plastic pancreatic duct stents fail to conform to the physiological curvature of the pancreas, while metal pancreatic duct stents with flared ends reduce migration but are associated with complications such as de novo strictures. Additionally, plastic and metal pancreatic duct stents require surgical removal. Whereas biodegradable pancreatic duct stents present a promising alternative due to their superior biocompatibility and ability to decompose into non-toxic materials, potentially eliminating the need for additional surgeries. Despite these advantages, biodegradable pancreatic duct stents remain in the experiment stage. This review assesses current materials of pancreatic duct stents, and emphasizes recent advancements in biodegradable options and emerging trends in clinical applications.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Pancreatitis Pathology and Treatment · Pancreatic and Hepatic Oncology Research · Pediatric Hepatobiliary Diseases and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. The pancreas-hermit of the abdomen10.1016/S0001-2092(06)61613-X ↗
2. Imaging of chronic pancreatitis (including groove and autoimmune pancreatitis)10.1016/j.rcl.2012.03.005 ↗
3. Treatment of pancreatic strictures10.1007/s11938-007-0035-x ↗
4. Two-step pancreatic duct stenting with endoscopic ultrasonography and balloon-assisted enteroscopy for pancreaticojejunal anastomotic stricture10.1055/a-1959-1416 ↗
5. Top tips for pancreatic duct strictures10.1016/j.gie.2023.01.003 ↗
6. Endoscopic management of chronic pancreatitis10.1111/den.13968 ↗
7. Feasibility of percutaneous pancreatic stent placement in postoperative pancreaticojejunostomy stenosis10.3348/kjr.2023.0459 ↗
8. Short internal pancreatic stent reduces pancreatic fistula in pancreatoduodenectomy10.1007/s00423-020-02036-1 ↗
9. Fully covered self-expandable metal stents to dilate persistent pancreatic strictures in chronic pancreatitis: long-term follow-up from a prospective study10.1016/j.gie.2018.08.019 ↗
10. Long-term outcomes of fully covered self-expandable metal stents versus plastic stents in chronic pancreatitis10.1038/s41598-021-94726-z ↗
11. A biodegradable non-covered self-expandable stent to treat pancreatic duct strictures in chronic pancreatitis: a proof of principle10.1016/j.gie.2017.08.018 ↗
12. New biliary and pancreatic biodegradable stent placement: a single-center, prospective, pilot study (with video)10.1016/j.gie.2020.02.049 ↗
13. Endoscopic treatment of painful chronic pancreatitis: evaluation of a new flexible multiperforated plastic stent10.1016/j.gcb.2008.05.017 ↗
14. 10 Fr S-type plastic pancreatic stents in chronic pancreatitis are effective for the treatment of pancreatic duct strictures and pancreatic stones10.1155/2018/6056379 ↗
15. A novel radiopaque biodegradable stent for pancreatobiliary applications–the first human phase I trial in the pancreas10.1016/j.pan.2012.02.016 ↗
16. Emerging trends in biliary stents: a materials and manufacturing perspective10.1039/D2BM00234E ↗
17. Novel biodegradable internal stent as a mitigation strategy in high-risk pancreaticojejunostomy: technical notes and preliminary results10.1007/s00595-022-02488-6 ↗
18. Research on a new type of ureteral stent material Zn-2Cu-0.5Fe-xMn with controllable degradation rate10.1016/j.heliyon.2024.e37629 ↗
19. Endoscopic cholangiopancreatoplasty: hydrostatic balloon dilation in the bile duct and pancreas10.1016/S0016-5107(83)72540-X ↗
20. Biliary and pancreatic stenting: devices and insertion techniques in therapeutic endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography10.4253/wjge.v8.i3.143 ↗
21. Endoscopic stents for the biliary tree and pancreas10.1007/s11938-017-0139-x ↗
22. Endoscopic management of pancreatic disorders: potential risks of pancreatic prostheses10.1055/s-2007-1010650 ↗
23. Simple modification of a pancreatic duct stent to prevent proximal migration10.1016/S0016-5107(93)70013-9 ↗
24. Efficacy of S-type stents for the treatment of the main pancreatic duct stricture in patients with chronic pancreatitis10.1080/00365520500383597 ↗
25. Initial evaluation of a new plastic pancreatic duct stent for endoscopic ultrasonography-guided placement10.1055/s-0034-1391083 ↗
26. Evaluation of a new stent for EUS-guided pancreatic duct drainage: long-term follow-up outcome10.1055/s-0044-101753 ↗
27. Endoscopic ultrasonography-guided pancreatic duct drainage after failed endoscopic retrograde cholangiopancreatography in patients with malignant and benign pancreatic duct obstructions10.1111/den.12100 ↗
28. The role of pancreatic stenting in obstructive ductal disorders other than pancreas divisum10.1016/S0016-5107(95)70127-3 ↗
29. Endoscopic stent therapy in advanced chronic pancreatitis: relationships between ductal changes, clinical response, and stent patency10.1111/j.1572-0241.2003.07381.x ↗
30. Long-term outcome after pancreatic stenting in severe chronic pancreatitis10.1055/s-2005-860988 ↗
31. Multiple stenting of refractory pancreatic duct strictures in severe chronic pancreatitis: long-term results10.1055/s-2005-921069 ↗
32. Endoscopic ultrasonography-guided drainage for patients with symptomatic obstruction and enlargement of the pancreatic duct10.3748/wjg.v21.i46.13140 ↗
33. Multiple stents are not superior to single stent insertion for pain relief in patients with chronic pancreatitis: a retrospective comparative study10.1055/a-1006-2658 ↗
34. Impact of physiologically shaped pancreatic stent for chronic pancreatitis10.1038/s41598-021-87852-1 ↗
35. Biomaterial applications in cardiovascular tissue repair and regeneration10.1586/erc.12.99 ↗
36. Biomedical applications of polyethylene10.1016/j.eurpolymj.2019.05.037 ↗
37. Pancreatic stents can induce ductal changes consistent with chronic pancreatitis10.1016/S0016-5107(90)70958-3 ↗
38. A review: fabrication of porous polyurethane scaffolds10.1016/j.msec.2014.12.037 ↗
39. Intermolecular interactions and self-assembling of polyurethane with poly(vinyl alcohol) in aqueous solutions10.1016/j.molliq.2018.11.018 ↗
40. Progress of polysaccharide-contained polyurethanes for biomedical applications10.1007/s13770-022-00464-2 ↗
41. Development and characterization of 3D printed ethylene vinyl acetate (EVA) as drug delivery device for the treatment of overactive bladder10.1080/03639045.2024.2311177 ↗
42. Focal pancreatic ductal change induced by 10‐Fr S‐type plastic stent in chronic pancreatitis10.1111/jgh.16052 ↗
43. Development of irreversible pancreatic ductal change triggered by pancreatic duct stenting in chronic pancreatitis10.1111/jgh.16733 ↗
44. Endoscopic treatment of chronic pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) guideline—updated August 201810.1055/a-0822-0832 ↗
45. Stent-induced pancreatic ductal and parenchymal changes: correlation of endoscopic ultrasound with ERCP10.1016/S0016-5107(96)70164-5 ↗
46. Long-term follow-up after multiple plastic stenting for refractory pancreatic duct strictures in chronic pancreatitis10.1055/a-0959-6163 ↗
47. EUS-guided pancreatic drainage for pancreatic strictures after failed ERCP: a multicenter international collaborative study10.1016/j.gie.2016.07.030 ↗
48. Efficacy of the novel guide sheath system for removing a migrated pancreatic duct stent after pancreaticoduodenectomy10.1111/den.14694 ↗
49. Novel method to remove deeply migrated pancreatic duct stent10.1055/a-1792-2469 ↗
50. The “zipline” technique for endoscopic removal of a migrated pancreatic stent10.1055/a-1978-7843 ↗
51. Application of a “retracting flaps” technique using a device delivery system for endoscopic removal of a pancreatic stent with 10 proximal flaps stuck in the pancreatic duct10.1055/a-2025-0342 ↗
52. Modified fully covered self-expandable metal stents with antimigration features for benign pancreatic-duct strictures in advanced chronic pancreatitis, with a focus on the safety profile and reducing migration10.1016/j.gie.2010.01.063 ↗
53. Covered metal stent or multiple plastic stents for refractory pancreatic ductal strictures in chronic pancreatitis: a systematic review10.1016/j.pan.2013.12.005 ↗
54. Expandable metal stents for benign pancreatic duct obstruction10.1016/S1052-5157(18)30197-1 ↗
55. Pancreatic duct stents10.1111/1751-2980.13158 ↗
56. Endoscopic removal of biliary self-expandable metallic stents: a prospective study10.1055/s-2006-944969 ↗
57. Temporary placement of a fully covered self-expandable metal stent in the pancreatic duct for management of symptomatic refractory chronic pancreatitis: preliminary data (with videos)10.1016/j.gie.2008.06.011 ↗
58. Feasibility and safety of a fully covered self-expandable metal stent with antimigration properties for EUS-guided pancreatic duct drainage: early and midterm outcomes (with video)10.1016/j.gie.2015.07.015 ↗
59. Nitinol manufacturing and micromachining: a review of processes and their suitability in processing medical-grade nitinol10.1016/j.jmapro.2019.01.003 ↗
60. Fully covered metal biliary stents: a review of the literature10.3748/wjg.v27.i38.6348 ↗
61. Feasibility and safety of placement of a newly designed, fully covered self-expandable metal stent for refractory benign pancreatic ductal strictures: a pilot study (with video)10.1016/j.gie.2008.07.027 ↗
62. A minimally invasive alternative for managing large pancreatic duct stones using a modified expandable metal mesh stent10.1159/000178881 ↗
63. Prospective pilot study of fully covered self-expandable metal stents for refractory benign pancreatic duct strictures: long-term outcomes10.1055/s-0042-115934 ↗
64. Metal stents placement for refractory pancreatic duct stricture in children10.3748/wjg.v24.i3.408 ↗
65. Pilot study of dumbbell-type covered self-expandable metal stent deployment for benign pancreatic duct stricture (with videos)10.1007/s11605-018-3901-z ↗
66. Preliminary study of a modified, nonflared, short, fully covered metal stent for refractory benign pancreatic duct strictures (with videos)10.1016/j.gie.2019.11.011 ↗
67. A prospective study of fully covered self-expandable metal stents for refractory benign pancreatic duct strictures10.5946/ce.2021.211 ↗
68. Self-expanding metallic stent for refractory pancreatic duct stricture in chronic pancreatitis: a prospective follow-up study10.1007/s12664-023-01445-6 ↗
69. Soft self-expandable metal stent to treat painful pancreatic duct strictures secondary to chronic pancreatitis: a prospective multicenter trial10.1016/j.gie.2022.09.021 ↗
70. Fully covered self-expanding metal stents for refractory pancreatic duct strictures in chronic pancreatitis10.1055/s-0032-1309774 ↗
71. Placement of a 6 mm, fully covered metal stent for main pancreatic head duct stricture due to chronic pancreatitis: a pilot study (with video)10.1177/1756283X16651855 ↗
72. Acetazolamide-eluting biodegradable tubular stent prevents pancreaticojejunal anastomotic leakage10.1016/j.jconrel.2021.06.010 ↗
73. Radiopaque chitosan ducts fabricated by extrusion-based 3D printing to promote healing after pancreaticoenterostomy10.3389/fbioe.2021.686207 ↗
74. A new biodegradable stent for the pancreaticojejunal anastomosis after pancreaticoduodenal resection: in vitro examination and pilot experiences in humans10.1097/00006676-200007000-00047 ↗
75. Biocompatibility of a new bioabsorbable radiopaque stent material (BaSO4 containing poly-L,D-lactide) in the rat pancreas10.1159/000092772 ↗
76. A novel biodegradable pancreatic stent for human pancreatic applications: a preclinical safety study in a large animal model10.1016/j.gie.2007.10.013 ↗
77. A novel biodegradable tubular stent prevents pancreaticojejunal anastomotic stricture10.1038/s41598-019-57271-4 ↗
78. Synthesis and design of norfloxacin drug delivery system based on PLA/TiO2 nanocomposites: antibacterial and antitumor activities10.1016/j.msec.2019.110337 ↗
79. In vitro and in vivo hydrolytic degradation behaviors of a drug-delivery system based on the blend of PEG and PLA copolymers10.1021/acsami.2c13141 ↗
80. Biocompatibility, biodegradation and excretion of polylactic acid (PLA) in medical implants and theranostic systems10.1016/j.cej.2018.01.010 ↗
81. Fabrication, characterization and evaluating properties of 3D printed PLA-Mn scaffolds10.1038/s41598-024-67478-9 ↗
82. Preliminary results on heparin-modified double-layered PCL and PLA-based scaffolds for tissue engineering of small blood vessels10.3390/jfb13010011 ↗
83. 3D-printed PLA-bioglass scaffolds with controllable calcium release and MSC adhesion for bone tissue engineering10.3390/polym14122389 ↗
84. Biodegradable weft-knitted intestinal stents: fabrication and physical changes investigation in vitro degradation10.1002/jbm.a.34759 ↗
85. A review on biodegradable biliary stents: materials and future trends10.1016/j.bioactmat.2022.01.017 ↗
86. Poly(lactide) stereocomplexes: formation, structure, properties, degradation, and applications10.1002/mabi.200500062 ↗
87. Synthesis and characterization of stereoblock poly(lactic acid)s with nonequivalent D/L sequence ratios10.1021/ma070156k ↗
88. Key factors of mechanical strength and toughness in oriented poly(l-lactic acid) monofilaments for a bioresorbable self-expanding stent10.1021/acs.langmuir.2c01972 ↗
89. Mechanical properties and in vitro degradation of bioabsorbable self-expanding braided stents10.1163/156856203763572707 ↗
90. PDS (polydioxanone suture): a new synthetic absorbable suture in cataract surgery. A preliminary study10.1159/000309144 ↗
91. New tubular bioabsorbable knitted airway stent: biocompatibility and mechanical strength10.1067/mtc.2002.118503 ↗
92. Polydioxanone weft-knitted intestinal stents: fabrication and mechanics optimization10.1177/0040517513483862 ↗
93. Absorbable stents for treatment of benign biliary strictures: long-term follow-up in the prospective Spanish registry10.1007/s00330-020-06797-7 ↗
94. Polydioxanone-based bio-materials for tissue engineering and drug/gene delivery applications10.1016/j.ejpb.2015.05.024 ↗
95. Efficacy and safety of biodegradable stents for refractory benign esophageal strictures: the BEST (Biodegradable Esophageal Stent) study10.1016/j.gie.2010.07.031 ↗
96. The biocompatibility of rapidly degrading polymeric stents in porcine carotid arteries10.1016/j.biomaterials.2010.06.057 ↗
97. A pilot study of endoscopically inserted biodegradable biliary stents in the treatment of benign biliary strictures and cystic duct leaks10.1016/j.gie.2017.10.042 ↗
98. Self-expandable biodegradable biliary stents in porcine model10.1016/j.jss.2014.08.006 ↗
99. Study of the hydrolytic degradation of polydioxanone PPDX10.1016/S0141-3910(00)00062-8 ↗
100. PDS (polydioxanone suture): a new synthetic absorbable suture in cataract surgery. A preliminary study10.1159/000309144 ↗