Synthetic vascular graft with spatially distinct architecture for rapid biomimetic cell organisation in a perfusion bioreactor
Source abstract
Abstract
Abstract Access to lab-grown fully functional blood vessels would provide an invaluable resource to vascular medicine. The complex architecture and cellular makeup of native vessels, however, makes this extremely challenging to reproduce in vitro . Bioreactor systems have helped advanced research in this area by replicating many of the physiological conditions necessary for full-scale tissue growth outside of the body. A key element underpinning these technologies are 3D vascular graft templates which serve as temporary scaffolds to direct cell growth into similar cellular architectures observed in native vessels. Grafts further engineered with appropriate physical cues to accommodate the multiple cell types that reside within native vessels may help improve the production efficiency and physiological accuracy of bioreactor-grown vessel substitutes. Here, we engineered two distinct scaffold architectures into an electrospun vascular graft aiming to encourage the spatial organisation of human vascular endothelial cells (hCAECs) in a continuous luminal monolayer, co-cultured with human fibroblasts (hFBs) populating the graft wall. Using an electrospun composite of polycaprolactone and gelatin, we evaluated physical parameters including fibre diameter, fibre alignment, and porosity, that best mimicked the spatial composition and growth of hCAECs and hFBs in native vessels. Upon identifying the optimal scaffold architectures for each cell type, we constructed a custom-designed mandrel that combined these distinct architectures into a single vascular graft during a single electrospinning processing run. When connected to a perfusion bioreactor system, the dual architecture graft spatially oriented hCAECs and hFBs into the graft wall and lumen, respectively, directly from circulation. This biomimetic cell organisation was consistent with positive graft remodelling with significant collagen deposition in the graft wall. These findings demonstrate the influence of architectural cues to direct cell growth within vascular graft templates and the future potential of these approaches to more accurately and efficiency produce blood vessel substitutes in bioreactor systems.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · 3D Printing in Biomedical Research · Angiogenesis and VEGF in Cancer
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (39)
Show source-provided references
1. Role of bioreactor technology in tissue engineering for clinical use and therapeutic target design10.3390/bioengineering5020032 ↗
2. Development of perfusion bioreactor for whole organ engineering—a culture system that enhances cellular engraftment, survival and phenotype of repopulated pancreas10.1142/S2339547818500085 ↗
3. New generation of bioreactors that advance extracellular matrix modelling and tissue engineering10.1007/s10529-018-2611-7 ↗
4. An intelligent bioreactor system for the cultivation of a bioartificial vascular graft10.1002/elsc.201600138 ↗
5. Bioreactors for cardiac tissue engineering10.1002/adhm.201701504 ↗
6. Vascular tissue engineering: progress, challenges, and clinical promise10.1016/j.stem.2018.02.009 ↗
7. The role of blood vessels, endothelial cells, and vascular pericytes in insulin secretion and peripheral insulin action10.1210/er.2009-0035 ↗
8. The endothelium and its role in regulating vascular tone10.2174/1874192401004010302 ↗
9. Monocyte adhesion to the endothelium is an initial stage of atherosclerosis development10.1016/j.crvasa.2015.08.002 ↗
10. It takes two: endothelial-perivascular cell cross-talk in vascular development and disease10.3389/fcvm.2018.00154 ↗
11. Bacakova · 2018 · 22910.5772/intechopen.77115 ↗
12. Differential functional roles of fibroblasts and pericytes in the formation of tissue-engineered microvascular networks in vitro10.1038/s41536-019-0086-3 ↗
13. Immune and inflammatory mechanisms of atherosclerosis10.1146/annurev.immunol.021908.132620 ↗
14. The requirement for fibroblasts in angiogenesis: fibroblast-derived matrix proteins are essential for endothelial cell lumen formation10.1091/mbc.e11-05-0393 ↗
15. A novel bioreactor system for the assessment of endothelialization on deformable surfaces10.1038/srep38861 ↗
16. Development of a bioreactor system for pre-endothelialized cardiac patch generation with enhanced viscoelastic properties by combined collagen I compression and stromal cell culture10.1002/term.3129 ↗
17. Decellularized tissue-engineered blood vessel as an arterial conduit10.1073/pnas.1019506108 ↗
18. Generating vascular conduits: from tissue engineering to three-dimensional bioprinting10.1515/iss-2018-0016 ↗
19. Cell-seeding techniques in vascular tissue engineering10.1089/ten.teb.2009.0527 ↗
20. Integration of induced pluripotent stem cell-derived endothelial cells with polycaprolactone/gelatin-based electrospun scaffolds for enhanced therapeutic angiogenesis10.1186/s13287-018-0824-2 ↗
21. Ngamkham · 201710.1101/120279 ↗
22. Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology10.1038/s42003-021-02285-w ↗
23. The in vivo blood compatibility of bio-inspired small diameter vascular graft: effect of submicron longitudinally aligned topography10.1186/1471-2261-13-79 ↗
24. Three-layered silk fibroin tubular scaffold for the repair and regeneration of small caliber blood vessels: from design to in vivo pilot tests10.3389/fbioe.2019.00356 ↗
25. Vascular replacement using a layered elastin-collagen vascular graft in a porcine model: one week patency versus one month occlusion10.1080/15476278.2015.1038448 ↗
26. Heterotypic scaffold design orchestrates primary cell organization and phenotypes in cocultured small diameter vascular grafts10.1002/adfm.201905987 ↗
27. Perfusion bioreactor for small diameter tissue-engineered arteries10.1089/1076327041348536 ↗
28. The effect of flow rate on morphology and deposition area of electrospun nylon 6 nanofiber10.1177/155892501200700414 ↗
29. Effect of voltage and flow rate electrospinning parameters on polyacrylonitrile electrospun fibers10.1088/1757-899X/318/1/012076 ↗
30. A validated software application to measure fiber organization in soft tissue10.1007/s10237-016-0776-3 ↗
31. The influence of electrospun scaffold topography on endothelial cell morphology, alignment, and adhesion in response to fluid flow10.1002/bit.24995 ↗
32. Fibroblast activation in vascular inflammation10.1111/j.1538-7836.2011.04209.x ↗
33. Apparatus for preparing electrospun nanofibers: designing an electrospinning process for nanofiber fabrication10.1002/pi.2345 ↗
34. Fabrication of strong, bioactive vascular grafts with PCL/collagen and PCL/silica bilayers for small-diameter vascular applications10.1016/j.matdes.2019.108079 ↗
35. Dynamic flow priming programs allow tuning up the cell layers properties for engineered vascular graft10.1038/s41598-021-94023-9 ↗
36. Successful development of small diameter tissue-engineering vascular vessels by our novel integrally designed pulsatile perfusion-based bioreactor10.1371/journal.pone.0042569 ↗
37. Bioengineered three-layered robust and elastic artery using hemodynamically-equivalent pulsatile bioreactor10.1161/CIRCULATIONAHA.107.757369 ↗
38. The effect of bioreactor induced vibrational stimulation on extracellular matrix production from human derived fibroblasts10.1016/j.biomaterials.2008.08.035 ↗
39. Dual function of perivascular fibroblasts in vascular stabilization in zebrafish10.1371/journal.pgen.1008800 ↗