Repeatability and sensitivity of quartz crystal microbalance (QCM) sensor array modified with four sensitive materials
Source abstract
Abstract
With continuous expansion of livestock and poultry breeding industry, the emission of harmful gases has inevitably increased which has also prompted the rapid development of research on harmful gases detection, such as quartz crystal microbalance(QCM)sensors. In this research, a gas-sensing system based on QCM sensor array modified with ethyl cellulose (EC), polyethyleneimine (PEI), tetramethylammonium fluoride tetrahydrate (TMAF), and polypyrrole (PPy) was established to detect three standard harmful gases, namely CO 2, NH 3, and H 2S. It has been observed that the QCM sensors modified with four materials had a good repeatability and a significant response to the three standard harmful gases. Furthermore, the suitable concentrations of the sensitive materials were 20 mg/ml for EC, 10 mg/ml for TMAF, 35 mg/ml for PEI, and 7 mg/ml for PPy. The frequency shift resulted by modified mass of the sensors for the four materials with the best concentrations were 21,343.1 Hz for EC, 21,065.5 Hz for TMAF, 2736.9 Hz for PEI, and 5292.4 Hz for PPy. Additionally, there was a linear relationship between the frequency shift and the concentration of three sample gases in different ranges with a high linear fit coefficient ( R 2>0.92), except TMAF versus CO 2. Moreover, R 2 with blank quartz wafer compensation was slightly smaller than which one without compensation. Therefore, the gas-sensing system based on QCM sensor array has an ideal repeatability and recovery response to the three standard gases, and the sensitivity performance was good. This work provides basic information for the research on QCM sensor array in gas detection.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Chemical Sensor Technologies · Gas Sensing Nanomaterials and Sensors · Acoustic Wave Resonator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Simultaneous chemical and sensory characterization of volatile organic compounds and semi-volatile organic compounds emitted from swine manure using solid phase microextraction and multidimensional gas chromatography-mass spectrometry-olfactometry10.2134/jeq2006.0382 ↗
2. Effect of heating system using a geothermal heat pump on the production performance and housing environment of broiler chickens10.3382/ps.2011-01666 ↗
3. Detailed study of odor from pig buildings to improve understanding of biotrickling filter performance10.13031/trans.12156 ↗
4. On-farm pilot-scale testing of black ultraviolet light and photocatalytic coating for mitigation of odor, odorous VOCs, and greenhouse gases10.1016/j.chemosphere.2019.01.086 ↗
5. Environmental assessment of three egg production systems--part II. ammonia, greenhouse gas, and particulate matter emissions10.3382/ps/peu075 ↗
6. Can dietary manipulations improve the productivity of pigs with lower environmental and economic cost? A global meta-analysis10.1016/j.agee.2019.106748 ↗
7. Research progress on interference in the detection of pollutant gases and improving technology in livestock farms: a review10.1080/05704928.2016.1208213 ↗
8. Review of measurement technologies for air pollutants at livestock and poultry farms
9. QCM formaldehyde sensing materials: design and sensing mechanism10.1016/j.snb.2019.04.050 ↗
10. Selective detection of trace p-xylene by polymer-coated QCM sensors10.1016/j.snb.2012.03.060 ↗
11. Selective detection of trace 1-butanol by QCM sensor coated with copolymer P (HEMA-co-MA)10.1016/j.snb.2011.08.055 ↗
12. Fabrication of a sensor array based on quartz crystal microbalance and the application in egg shelf life evaluation10.1016/j.snb.2018.03.010 ↗
13. Cu-doped ZnO nanorods based QCM sensor for hazardous gases10.1016/j.jallcom.2020.154177 ↗
14. High-performance formaldehyde adsorption on CuO/ZnO composite nanofiber coated QCM sensors10.1016/j.jallcom.2018.12.237 ↗
15. Enhanced sensitivity and selectivity of ammonia sensing by QCM modified with boric acid-doped PVAc nanofiber10.1016/j.sna.2020.111902 ↗
16. GC-like graphene-coated quartz crystal microbalance sensor with microcolumns10.1021/acsami.0c19010 ↗
17. Discrimination of wood borers infested Platycladus orientalis trunks using quartz crystal microbalance gas sensor array10.1016/j.snb.2020.127767 ↗
18. Preparation of molecularly imprinted polymer nanobeads for selective sensing of carboxylic acid vapors10.1016/j.aca.2018.01.004 ↗
19. LSPR sensor array based on molecularly imprinted sol-gels for pattern recognition of volatile organic acids10.1016/j.snb.2017.04.048 ↗
20. QCM virtual multisensor array for fuel discrimination and detection of gasoline adulteration10.1016/j.fuel.2017.02.066 ↗
21. Experimental study on ripening stage of bananas based on quartz crystal microbalance sensor detection
22. High-performance QCM humidity sensor based on graphene oxide/tin oxide/polyaniline ternary nanocomposite prepared by in-situ oxidative polymerization method10.1016/j.snb.2018.02.012 ↗
23. Facile fabrication of high-performance QCM humidity sensor based on layer-by-layer self-assembled polyaniline/graphene oxide nanocomposite film10.1016/j.snb.2017.08.212 ↗
24. Quantitative detection of formaldehyde and ammonia gas via metal oxide-modified graphene-based sensor array combining with neural network model10.1016/j.snb.2016.08.085 ↗
25. Aliphatic amines vapours detection by quartz crystal microbalance sensor10.1016/j.snb.2014.03.020 ↗
26. Morphology control strategies for solution-processed organic semiconductor thin films10.1039/C4EE00688G ↗
27. Quartz crystal microbalance VOCs sensor based on dip coated polyaniline emeraldine salt thin films10.1016/j.snb.2014.07.030 ↗
28. Rapid detection of d-limonene emanating from citrus infestation by Bactrocera dorsalis (Hendel) using a developed gas-sensing system based on QCM sensors coated with ethyl cellulose10.1016/j.snb.2020.129048 ↗