High electrochemical response of TiO2@C-dots nanocomposites as electrode modifiers for Pb (II) detection
Source abstract
Abstract
The synthesis of new modifiers based on nanomaterials as Pb (II) sensing electrode composites has attracted much attention in recent years. Modifiers are believed to produce stable electrodes with good sensitivity. In this study, we synthesized TiO 2 -incorporated carbon dots (TiO 2@C-dots) and tested their performance as modifiers in the detection of Pb (II) using a carbon paste electrode (CPE). The fabrication of TiO 2@C-dots-decorated CPE (CPE/TiO 2 @C-dots) has been carried out using several methods including electrochemical, hydrothermal impregnation, and mechanical homogenization at low temperatures. Based on the results of SEM, XRD, and FTIR characterization, the morphology of the nanocomposites is known to consist of uniform solid particles. Also, there are voids on the nanocomposite surface. The nanocomposite has an average particle size of 22.61 nm and a specific 2θ angle of 26.33°. The nanocomposites actively absorb IR at specific wavenumbers of 3600 cm −1 (-OH stretch) and 1759 cm −1 (C O stretch). Performance test results for Pb (II) detection showed that decorative modifiers (TiO 2 @C-dots) and CPE affected the peak redox current of Pb (II). This effect correlates with the mass of TiO 2@C-dots, with a mass of 10.0 mg being the best mass for TiO 2 @C-dots. During the detection process, Pb (II) underwent redox reactions with oxidation (Epa) and reduction (Epc) potential values of −0.38 V and −0.50 V, respectively. During application, it is controlled by the interaction diffusivity with the Pb (II) molecule, yielding an accuracy of 0.36%.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical Analysis and Applications · Electrochemical sensors and biosensors · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. Enhanced-charge transfer over molecularly imprinted polyaniline modified graphene/TiO2 nanocomposite electrode for highly selective detection of fipronil insecticide10.1016/j.mssp.2022.106994 ↗
2. A novel analytical method for sensitive determination of lead: hydrogen assisted T-shape slotted quartz tube-atom trap-flame atomic absorption spectrometry10.1016/j.microc.2017.10.015 ↗
3. Tailoring multifunctional gel for sensitive naked-eye and fluorescence dual-mode detection and effective adsorption of cadmium (Ⅱ) and lead (Ⅱ) ions in water10.1016/j.cej.2021.132367 ↗
4. Fast method of elements determination in slim coffees by ICP OES10.1016/j.foodchem.2013.09.054 ↗
5. Determination of lead in vinegar by ICP-MS and GFAAS: evaluation of different sample preparation procedures10.1016/j.talanta.2004.02.017 ↗
6. Analysis of Ti-and Pb-based particles in the aqueous environment of Melbourne (Australia) via single particle ICP-MS10.1007/s00216-022-04052-0 ↗
7. Determination of Pb (Lead), Cd (Cadmium), Cr (Chromium), Cu (Copper), and Ni (Nickel) in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry10.1016/j.jfda.2015.04.010 ↗
8. Comparative study of three digestion methods for elemental analysis in traditional medicine products using atomic absorption spectrometry10.1186/s40543-016-0085-6 ↗
9. Use of tartaric acid–citric acid–sucrose as chemical modifier for the determination of lead in several matrices employing ET AAS10.1016/j.microc.2015.12.032 ↗
10. Cloud point extraction for determination of lead in blood samples of children, using different ligands prior to analysis by flame atomic absorption spectrometry: a multivariate study10.1016/j.jhazmat.2011.06.017 ↗
11. Fast sequential multi element analysis of lead and cadmium in canned food samples using effervescent tablet-assisted switchable solvent based liquid phase microextraction (EA-SS-LPME) coupled with high-resolution continuum source flame atomic absorption s10.1016/j.foodchem.2021.131857 ↗
12. Biopolymer-modified carbon paste electrode for the electrochemical detection of Pb (II) in water10.1155/2022/5348246 ↗
13. A facile composite material for enhanced cadmium (II) ion capturing from wastewater10.1016/j.jece.2019.103378 ↗
14. Electrophoretic assembly of Sn-Bi film for the voltammetric determination of Cd (II) and Pb (II)10.1016/j.microc.2021.106265 ↗
15. A reduced graphene oxide supported Au-Bi bimetallic nanoparticles as an enhanced sensing platform for simultaneous voltammetric determination of Pb (II) and Cd (II)10.1016/j.microc.2021.107078 ↗
16. Plot-on-demand integrated paper-based sensors for drop-volume voltammetric monitoring of Pb (II) and Cd (II) using a bismuth nanoparticle-modified electrode10.1007/s00604-022-05335-0 ↗
17. Low-cost voltammetric sensors for robust determination of toxic Cd (II) and Pb (II) in environment and food based on shuttle-like α-Fe2O3 nanoparticles decorated β-Bi2O3 microspheres10.1016/j.microc.2022.107515 ↗
18. Simultaneous determination of Pb2+ and Hg2+ at food specimens by a melamine-based covalent organic framework modified glassy carbon electrode
19. Ultra-trace levels voltammetric determination of Pb2+ in the presence of Bi3+ at food samples by a Fe3O4@Schiff base Network1 modified glassy carbon electrode
20. Electrochemical detection of Pb (II) and Cd (II) at bismuth ferrite nanoparticles modified carbon paste electrode10.1039/D2MA00133K ↗
21. Ion imprinted-carbon paste electrode as electrochemical sensor for ultra-trace recognizing speciation of mercury10.1016/j.rechem.2022.100489 ↗
22. An efficient sensor for simultaneous determination of Hg (II) and as (III) using a carbon paste electrode modified with needle-shaped Pt-doped NiCo2O4 nanograss10.1016/j.snb.2022.131445 ↗
23. Carbon paste electrode modified with fern leave-like MIL-47 (as) for electrochemical simultaneous detection of Pb (II), Cu (II) and Hg (II)10.1016/j.jelechem.2021.115121 ↗
24. Voltammetric determination of lead (II) and cadmium (II) using a bismuth film electrode modified with mesoporous silica nanoparticles10.1016/j.electacta.2014.03.147 ↗
25. Stripping voltammetric determination of cadmium and lead ions based on a bismuth oxide surface-decorated nanoporous bismuth electrode10.1016/j.elecom.2022.107233 ↗
26. Bismuth-dispersed xerogel-based composite films for trace Pb (II) and Cd (II) voltammetric determination10.1016/j.aca.2013.01.040 ↗
27. Effect of Bi (III) concentration on the stripping voltammetric response of in situ bismuth-coated carbon paste and gold electrodes10.1016/j.electacta.2006.05.029 ↗
28. Voltammetric analysis of Pb (II) in natural waters using a carbon paste electrode modified with 5-mercapto-1-methyltetrazol grafted on hexagonal mesoporous silica10.1007/s00604-009-0287-3 ↗
29. Voltammetric sensing of Pb (II) using a glassy carbon electrode modified with composites consisting of Co3O4 nanoparticles, reduced graphene oxide and chitosan10.1016/j.jelechem.2017.07.046 ↗
30. Voltammetric determination of Pb (II) by a Ca-MOF-Modified carbon paste electrode integrated in a 3D-printed device10.3390/s20164442 ↗
31. A polyrutin/AgNPs coated GCE for simultaneous anodic stripping voltammetric determination of Pb (II) and Cd (II) ions in environmental samples10.1016/j.colsurfa.2022.129082 ↗
32. Nanoscale microreactor-encapsulation of 18-membered decaaza macrocycle nickel (II) complexes10.1016/j.inoche.2004.11.004 ↗
33. Oxidation of cyclohexene with tert-butylhydroperoxide and hydrogen peroxide catalysed by Cu (II), Ni (II), Co (II) and Mn (II) complexes of N, N′-bis-(α-methylsalicylidene)-2, 2-dimethylpropane-1, 3-diamine, supported on alumina10.1016/j.molcata.2005.05.026 ↗
34. Efficient Pb (II) adsorption in aqueous solution by hierarchical 3D/2D TiO2/CNNS nanocomposite10.1016/j.mseb.2022.116191 ↗
35. Electrochemical sensor based on a chitosan-molybdenum vanadate nanocomposite for detection of hydroxychloroquine in biological samples10.1016/j.jcis.2022.01.039 ↗
36. Electrode modifier performance of TiO2 incorporated carbon quantum dots nanocomposites on Fe(CN)63−/Fe(CN)64− electrochemical system10.1007/s11814-021-0980-4 ↗
37. Hydrothermal architecture of Cu5V2O10 nanostructures as new electro-sensing catalysts for voltammetric quantification of mefenamic acid in pharmaceuticals and biological samples10.1016/j.bios.2021.113017 ↗
38. Synthesis and characterization of CeO2 nanoparticles via hydrothermal route10.1016/j.jiec.2014.05.046 ↗
39. Electrochemical hydrogen storage capacity and optical properties of NiAl2O4/NiO nanocomposite synthesized by green method10.1016/j.ijhydene.2016.10.132 ↗
40. Study on the photocatalytic mechanism and detoxicity of gemfibrozil by a sunlight-driven TiO2/carbon dots photocatalyst: the significant roles of reactive oxygen species10.1016/j.apcatb.2016.11.040 ↗
41. TiO2/carbon composite nanomaterials for photocatalysis
42. TiO2/carbon dots decorated reduced graphene oxide composites from waste car bumper and TiO2 nanoparticles for photocatalytic applications10.1016/j.arabjc.2018.08.016 ↗
43. Photocatalytic removal of pharmaceutical water pollutants by TiO2–Carbon dots nanocomposites: a review10.1016/j.chemosphere.2022.134731 ↗
44. Porous TiO2/carbon dot nanoflowers with enhanced surface areas for improving photocatalytic activity10.3390/nano12152536 ↗
45. Preparation of carbon dots/TiO2 electrodes and their photoelectrochemical activities for water splitting10.1016/j.ijhydene.2017.01.228 ↗
46. Highly sensitive fipronil pesticide detection on ilmenite (FeO.TiO2)-carbon paste composite electrode10.1016/j.surfin.2019.05.008 ↗
47. Co-doped ZnO nanoparticles: structural, morphological, optical, magnetic and antibacterial studies10.1016/j.jmst.2014.07.013 ↗
48. Optical and magnetic properties of co-doped CuO flower/plates/particles-like nanostructures10.1166/jnn.2014.8514 ↗
49. Structural, optical and room-temperature ferromagnetic properties of Fe-doped CuO nanostructures10.1016/j.physe.2013.05.009 ↗
50. Structural, morphological, optical, and magnetic properties of Ni-doped CuO nanostructures prepared by a rapid microwave combustion method10.1016/j.mssp.2013.09.013 ↗
51. A novel carbon paste electrode modified by NP-Al2O3 for the electrochemical simultaneous detection of Pb (II) and Hg (II)10.1016/j.diamond.2020.107747 ↗
52. A sensitive voltammetric determination of anti-Parkinson drug pramipexole using titanium dioxide nanoparticles modified carbon paste electrode
53. High performance cypermethrin pesticide detection using anatase TiO2-carbon paste nanocomposites electrode10.1016/j.microc.2018.11.050 ↗
54. Nanocomposite design of graphene modified TiO2 for electrochemical sensing in phenol detection10.1007/s11814-021-0938-6 ↗
55. Synthesis and electrochemical performance of graphene-TiO2-carbon paste nanocomposites electrode in phenol detection10.1016/j.jpcs.2019.03.014 ↗
56. Characterization of a carbon paste electrode modified with tripolyphosphate-modified kaolinite clay for the detection of lead10.1016/j.talanta.2011.06.014 ↗
57. Square wave anodic stripping voltammetric determination of Cd2+ and Pb2+ at bismuth-film electrode modified with electroreduced graphene oxide-supported thiolated thionine10.1016/j.talanta.2014.01.062 ↗
58. Highly sensitive determination of cadmium and lead using a low-cost electrochemical flow-through cell based on a carbon paste electrode10.2116/analsci.28.141 ↗
59. Construction and characterization a non-amalgamation voltammetric flow sensor for online simultaneous determination of lead and cadmium ions10.1016/j.snb.2017.06.098 ↗