Study of ethylene cracking furnace tube operational failure after service and welding repair
Source abstract
Abstract
Damage always occurs on ethylene cracking furnace tube under critical operation conditions and the tube needs welding repair.To find out the reason for welding failure of long-term served ethylene cracking furnace tube,the microstructure and performance evolution of the tube after service was investigated by metallographic observation and thermodynamics calculation.Main influencing factors of furnace tubes was analyzed and reasonable heat-treating process was made to improve the weld ability.The results show that the precipitated phases are M23C6、M7C3 and little MC after long-term served and the density of the precipitates in the matrix becomes higher and the size becomes larger.The precipitated phases distribute as chain-like along grain boundaries is the main reason for welding failure because it decreases plasticity seriously.By heat treatment the carbides morphology is changed,and the plastic deformation of old tube improves significantly.Based on the thermodynamic calculation result,when the Cr solution content is more than 10% in matrix,the precipitation process is M23C6 precipitates,and when it is less than 10%,the precipitation process is M7C3 precipitates.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: High Temperature Alloys and Creep · Microstructure and Mechanical Properties of Steels · Hydrogen embrittlement and corrosion behaviors in metals