Electrochemical behavior of crevice samples of Ti6Al4V alloy implanted carbon ion in Hank′s solution
Source abstract
Abstract
To explore the characteristic of Ti-6Al-4V alloy implanted carbon iontion in Hank's simulated body fluid solution,the electrochemical behavior of crevice samples was studied by electrochemical method in Hank's artificial body fluids.The results showed that the corrosion potential of implanted samples moved toward positive,the charge transfer resistance turned to big,and the anodic polarized current density was reduced during crevice corrosion,which resulted in improving its electrochemical characteristic.The reason lied in the unordered film formed on the surface of Ti-6Al-4V alloy,which was mainly composed of TiC after implantation.The unordered film blocked alloy element to dissolve and improved alloy′s crevice corrosion resistance.