Design and properties of graded ceramic coatings on water-wall tubes
Source abstract
Abstract
A ceramic coating structure is designed of which the thermal expansion coefficient(TEC) is changing across the graded coating to solve the problem of breakage for water-wall tubes of coal-fired power plant.To improve shear strength between coating and substrate,the distribution of temperature and stress fields of coating and tubes were calculated.The results showed that the maximum of thermal stress was 1.78 MPa at the interface between coating and substrate.Furthermore,the thermal stress was proportion to the TEC.So two layers graded coating structure was designed by adjusting the content of every component to change TEC.However,tensile test showed that the shear strength of coating was 5.6 MPa,about three times of the maximum thermal stress of the interface.So the graded ceramic coating with TEC changing can efficiently relax thermal stress of interface between coating and substrate.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Adsorption and Cooling Systems · Phase Change Materials Research · Vibration and Dynamic Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References