Adaptation strategy of finishing temperature control for hot strip rolling
Source abstract
Abstract
On the basis of the impact of water-cooling colligation coefficient of heat transfer on finishing temperature and the temperature change during finish rolling,a self-adaptation model was established for adjusting water-cooling colligation coefficient.Off-line software was built up for self-adapted calculation on the coefficient of finishing temperature control model according to the in-site measured data.By using the software,the effect of variation of self-adaptation coefficient on the finishing temperature of stripe steel can be checked up by pre-enacting a temperature value.The calculation results indicate that the built model is effective and the self-adaptation coefficient can vary promptly with different finishing temperatures of stripe steel to make the calculated value of temperature timely approach the measured value.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Metallurgy and Material Forming · Laser and Thermal Forming Techniques · Iterative Learning Control Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.